LIGHT LIGHT-ECM CASSETTE FAN COIL UNIT

Open the catalog to page 1
LIGHT - 2

AUTOMATIC LOUVERS EASY INSTALLATION AND MAINTENANCE LIGHT, the new cassette fan coil unit 2015-3 LIGHT is the new cassette fan coil unit characterised by innovative design and a perfect blend of performance, low sound emission and extreme ease of installation and maintenance. The unit is produced in modular dimensions of 600 x 600mm and is available in 5 different capacities for the 2 pipe versions (61-62-63-64-65), and in 6 capacities for the 4 pipe versions (81-82-83-83C-84-84C). The models 83 and 84 are designed mainly for heating, whereas the plus 83C and 84C versions are more for...

Open the catalog to page 2
LIGHT - 3

INTEGRATED ELECTRIC HEATER INTEGRATED VALVES VALVE SYSTEM Automatic louvers Integrated valves Integrated electric heater Easy installation and maintenance It allows accurate and precise regulation of the fan by limiting the power of the effective work load, without any useless waste. For a in perfect control of the climatic comfort in cooling and heating modalities. For a 360° room comfort that ensures that particular condition of physical and psychological well-being of the individual. It helps to avoid unnecessary energy thermal dispersion in case the unit is turned off. It allows an...

Open the catalog to page 3
LIGHT - 4

LIGHT, a comfort solution The design of the front panel made from pure white ABS is an excellent compromise of style, efficiency and functionality. Its particular geometry and the positioning of the air distribution louvers on the perimeter combine to control the air flow precisely and directly, offering the possibility to set up the best kind of diffusion, whether automatic or manual, based on the climatic requirements resulting in perfect control of the climatic comfort in cooling and heating modalities. Coanda Effect The position of the lateral air distribution louvers allows maximum...

Open the catalog to page 4
LIGHT - 5

Anti stratification effect In heating modality, the air distribution louvers are positioned automatically (optional) with an opening of 35°, allowing the warm air to create a downward airflow, ensuring the homogenous distribution of the room temperature and avoiding the problems linked to air stratification. REMOTE CONTROL

Open the catalog to page 5
LIGHT - 6

LIGHT and details Front panel LIGHT is an innovative cassette fan coil unit, the result of accurate planning and design research to optimise the functional performance of the unit and guarantee optimal comfort and an aesthetically pleasing product. The extremely thin front panel made of glaze pure white RAL9010 ABS, with its modern and minimalist design, can integrate perfectly with any kind of installation, residential or commercial, such as offices, stores and public places in general. The LIGHT cassette panel follows the 600x600mm modular design for perfect integration with the standard...

Open the catalog to page 6
LIGHT - 7

Maintenance operations can be even simpler and faster thanks to the EasyWaySystem above all when unit is installed in modular false ceilings, allowing an excellent accessibility to all the main components in need of ordinary or extraordinary maintenance, thanks to an easily removed side panel that allows to avoid the typical procedure to remove grill, filter and main drain pan. Once the side panel is removed the main components such as the valves, condensate drain pump, float, main drain pan and all the electric cabling can be easily accessed. The EasyWaySystem system guarantees the...

Open the catalog to page 7
LIGHT - 8

saving while respecting the environment LIGHT-ECM series is equipped with an innovative EC Brushless synchronous motor controlled by an inverter installed on board, that allows accurate and precise regulation of the fans by limiting the power of the effective work load, without any useless waste. Compared to a unit with a traditional asynchronous motor, the LIGHT-ECM series ensures an exceptional decrease up to 78% in energy consumption, even when it is functioning at low speed. The EC motor version allows remarkable economic savings and relative decrease of CO2 emissions in the atmosphere,...

Open the catalog to page 8
LIGHT - 9

LIGHT / LIGHT-ECM TECHNICAL DATA Coil fittings Condensate drain fitting UNIT WEIGHT Unit Front panel Front panel PACKED UNIT DIMENSIONS PACKED UNIT WEIGHTS Unit Front panel WATER CASSETTE DIMENSIONS (mm) (with auxiliary drain pan)

Open the catalog to page 9
LIGHT - 10

LIGHT / LIGHT-ECM Sensible cooling capacity Total cooling capacity Water pressure drop Heating capacity Sound power level (E) Water pressure drop Sound pressure level ASYNCHRONOUS MOTOR (LIGHT 61-65 NC/RC) Absorbed power Absorbed current EC BRUSHLESS MOTOR (LIGHT-ECM 61-65 NC/RC) Absorbed power Absorbed current ELECTRIC HEATER (LIGHT 61-65 NC-E/RC-E) Electric heater Power supply - Standard unit with free outlet: external static pressure = 0 Pa Sound power level: ISO 23741 Sound pressure level: 8,6 dB(A) lower that the sound power level for a room of 90 m3 with a reverberation time of 0,5...

Open the catalog to page 10
LIGHT - 11

LIGHT / LIGHT-ECM Sensible cooling capacity Total cooling capacity Water pressure drop Heating capacity Sound power level Water pressure drop Sound pressure level ASYNCHRONOUS MOTOR (LIGHT 81-84 NC/RC) Absorbed power Absorbed current Absorbed power Absorbed current - Standard unit with free outlet: external static pressure = 0 Pa Sound power level: ISO 23741 Sound pressure level: 8,6 dB(A) lower that the sound power level for a room of 90 m3 with a reverberation time of 0,5 sec. Supported power supply: ~230V±10% / 1ph / 50Hz COOLING Inlet water temp.: 7°C Outlet water temp.: 12°C Inlet air...

Open the catalog to page 11
LIGHT - 12

A GROUP TAKES PART TO THE EUROVENT PROGRAM OF FAN COIL PERFORMANCE CERTIFICATION IN ORDER TO PROVIDE ITS CUSTOMERS THE RELIABILITY AND ACCURACY OF PERFORMANCES. A GROUP S.p.A. - Via Montegrappa, 67 - 31020 San Zenone degli Ezzelini (Treviso) - Italy Tel. +39 0423 969037 - Fax +39 0423 968197 - www.ventilclima.com - info@ventilclima.com