1. Catalogs
  2. Ventilation Systems JSC
  3. Smoke estraction and ventilation

Smoke estraction and ventilation

Smoke estraction and ventilation
1 / 64 PagesView full catalog

Smoke estraction and ventilation

Product catalog summary
Company Overview
VENTS, established in the 1990s, is a leading company in the ventilation industry, exporting to over 90 countries. The company focuses on research and development, quality control, and environmental protection, adhering to ISO 9001:2000 standards. VENTS is a member of several international HVAC organizations.
Smoke Extraction Systems
Smoke control systems are essential for fire safety, facilitating safe evacuation by extracting smoke and preventing its spread. These systems are integrated during the building's construction phase and must comply with construction standards. Key components include smoke exhaust fans, smoke dampers, fire-resisting dampers, and pressurization fans.
Roof Centrifugal Smoke Extraction Fan (VENTS VKDV/VKDH)
These fans are used in emergency systems to remove smoke and hot gases, capable of handling temperatures up to 600°C for 120 minutes. They are made of heat-resistant steel and available with horizontal or vertical air discharge.
Specifications
  • Fan Series VKDV/VKDH: Designed for smoke removal with vertical or horizontal air discharge. Available in various impeller diameters (630 to 1100 mm) and power capacities (1.5 to 37 kW). Maximum air temperature handling is 600°C. Motor ingress protection rating is IP 54.
  • Fan Series VKT: Specifically for fireplaces, with air capacity up to 1000 m3/h. Handles smoke fume temperatures up to 400°C. Equipped with a single-phase motor and sound pressure level of 52 dB(A).
  • Damper Series KPD/KPDU: Fire safety dampers with a fire resistance rating of 180 minutes at 600°C. Available with single or multiple louvres and various actuator types (electromagnet or Belimo actuator).
Design and Features
  • Fans are made of galvanized steel with a polymer coating for durability against weather and aggressive environments. They include protective grilles and backward-curved blades to minimize soot deposits.
  • Dampers are constructed from 1.5 mm thick galvanized steel and are available in wall or duct-mounted variants. They feature manual and automatic control options.
Installation Guidelines
  • Fans should be mounted on roofs with adequate space for maintenance. They require connection to power mains via a speed controller for optimal operation.
  • Dampers should not be installed in explosive or highly flammable environments. They must be regularly cleaned to prevent flammable deposits.
Applications
  • Fans are suitable for extracting smoke from fireplaces, furnaces, and hearths, as well as for standard ventilation purposes.
  • Dampers are used in smoke control systems to extract combustion products and support evacuation during fires.
Damper Variants and Actuator Types
The document describes single-flange and double-flange variants of KPDU and KPD dampers. Dampers can be equipped with internal or external Belimo electric actuators or electromagnets, available in 230V or 24V options.
Installation Recommendations
Guidelines for installing dampers in vertical and horizontal building structures are provided, emphasizing the importance of selecting the correct BxH cross-section damper based on spatial orientation.
Fire Safety Features
KP-1 series dampers are designed to resist fire for at least 60 minutes at 600°C. They can be equipped with mechanical actuating units with thermal fuses and return springs or electric actuators with built-in return springs and thermal breakers.
Technical Specifications
The document provides detailed specifications for various damper models, including dimensions, weights, and flow area data. It also includes technical specifications for electric actuators, such as rated voltage, power input, torque, and swing time.
Installation Procedures
Fire-resisting dampers must comply with applicable standards, ensuring the seal's fire resistance matches the building envelope. A minimum access space of 350 mm is required, and inspection holes must be arranged.
See more

Catalog excerpts

Smoke estraction and ventilation-2

Industrial and commercial ventilation (Catalogue no. 1) Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation components - fans for round and rectangular ducts, sound-insulated, axial and roof fans, air handling units with heat recovery, air heating units, accessories. Energy saving supply and exhaust units and air handling units with heat recovery with air capacity up to 6500 m3/h. Smoke removal and ventilation (Catalogue no. 5) Domestic ventilation (Catalogue no. 6) Smoke protection systems of buildings and premises. Domestic ventilation: fans,...

 Open the catalog to page 2
Smoke estraction and ventilation-3

Air handling units AIRVENTS (Catalogue no. 3) Energy saving air handling units with air capacity up to 40 000 m3/h, for use in large residential, industrial and commercial objects. Domestic fans (Catalogue no. 7) Domestic fans with air capacity up to 365 m3/h with extra functions: timer, humidity sensor, motion sensor, etc. Applied for premises up to 30 m2. Energy saving ventilation Geothermal systems GEO VENTS (Catalogue no. 4) Energy saving system GEO VENTS with use of the earth’s surface layers heat. High ventilation system energy efficiency and low operating costs. VENTS VN Mono-pipe exhaust...

 Open the catalog to page 3
Smoke estraction and ventilation-4

About Company Smoke Extraction Typical Smoke Control System Solution Roof Centrifugal Smoke Extraction Fan VENTS VKDV / VENTS VKDH Roof Exhaust Gas Extraction Booster Fan for Fireplaces VENTS VKT VENTS. Smoke Extraction and Ventilation | Catalogue no.5 | 06-2014

 Open the catalog to page 4
Smoke estraction and ventilation-5

Multi-Purpose Fire Safety Smoke Damper VENTS KPD Multi-Purpose Fire Safety Smoke Damper VENTS KPDU Fire-Resisting Damper (EI 60) VENTS KP-1...72S / VENTS KP-1...BLF / VENTS KP-1...BF Fire-Resisting Damper (EI 120) VENTS KP-2...72S / VENTS KP-2...BLF / VENTS KP-2...BF Simplified Fire-Resisting Damper (EI 120) VENTS KP-2...BLF-1 / VENTS KP-2...BF-1 Fire-Resisting Damper VENTS PL-10 VENTS. Smoke Extraction and Ventilation | Catalogue no.5 | 06-2014

 Open the catalog to page 5
Smoke estraction and ventilation-6

WELCOME TO THE VENTS WORLD! VENTS company was founded in the nineties of the XXth century. Dynamic development of the enterprise and ongoing study of the consumer demand enabled rapid international leadership of the company in the ventilation industry. VENTS is a powerful research and development enterprise with 2500 professionals working as a single team to ensure a full production cycle from idea to end product. The production base of the company is located at more than 60 000 m2 area. It includes 16 workshops equipped under the latest international standards and each of them is comparable...

 Open the catalog to page 6
Smoke estraction and ventilation-7

Metal processing workshop Spiral air ducts workshop Flexible air ducts workshop Aluminium grilles and diffusers workshop Powder coating workshop Extrusion workshop Injection moulding workshop Residential fans workshop Ventilation grilles workshop Electric motors workshop Industrial fans workshop Air handling units workshop AirVents air handling unit workshop Electrical accessories workshop Extruded grilles workshop Powerful production facilities, high automation level, active implementation of innovative technologies in the production process made VENTS a worldwide ventilation leader. We manufacture...

 Open the catalog to page 7
Smoke estraction and ventilation-8

Smoke control is a complex process involving smoke extraction and fresh air supply by the supply and extract ventilation system of buildings in order to ensure safe evacuation of people in case of a fire in any of the spaces. The smoke control system of a building or structure must ensure protection of people along the evacuation paths from the fire hazards during the time required for the personnel evacuation procedure or the entire period of fire development and control by means of extracting the combustion and thermal decomposition products and/or preventing their spreading. A smoke control...

 Open the catalog to page 8
Smoke estraction and ventilation-9

Smoke control system functions: Prevention of smoke spreading from the ignition source. Prevention of smoke transfer to the evacuation paths (maintaining acceptable conditions for the people being evacuated from the building). Maintaining a microclimate beyond the ignition source area to enable normal operation of fire-fighting teams. Protecting the life of people in the building. Protecting the property against damage. The smoke control system elements are integrated at the initial phase of the building (residential complex, office block, warehouse facility etc.) construction. These communications...

 Open the catalog to page 9
Smoke estraction and ventilation-10

Sample scheme and operation of a smoke-extraction system in a multi-storey residential building with an underground car park: VENTS. Smoke Extraction and Ventilation | Catalogue no.5 | 06-2014

 Open the catalog to page 10
Smoke estraction and ventilation-11

Typical Smoke Control System Solution In case of a fire on Floor 2: Ventilation system: fire-resisting dampers KP 3 and 4 block the floor 2 (closed), thus containing the fire and smoke at the ignition floor, fire-resisting dampers 2 and 6 remain open enabling pressurisation of the adjacent floors 1 and 3 by the supply ventilation system while fire-resisting dampers KP 1 and 5 in the KP exhaust ventilation branch remain closed. Smoke control system: smoke extraction is handled by the VKDV (VKDH) fan via the open KPDU 11 damper, the supply air is fed from the air pressurisation system via the open...

 Open the catalog to page 11
Smoke estraction and ventilation-12

ROOF-MOUNTED SMOKE REMOVAL FANS Roof-mounted centrifugal fan for smoke removal with vertical air discharge designed for operation in moderate and tropical climatic areas. Roof-mounted centrifugal fan for smoke removal with horizontal air discharge Applications Used in emergency air extract systems and are designed for mechanical removal of smoke, hot gases and withdrawal of heat outside of the serviced premise in case of fire. Recommended for use in industrial, public, residential, administrative and other premises. Accessory: Mounting frame RKV. The mounting frame is designed for mounting of...

 Open the catalog to page 12
Smoke estraction and ventilation-13

Technical data: VKDV / VKDH 630-600-1,5/930 Voltage [V] / 50 Hz Installed power capacity Ny [kW] Motor ingress protection rating Weight [kg] Curve number at the diagram Voltage, 50 Hz [V] Installed power capacity Ny [kW] Rated current [A] Motor ingress protection rating Weight [kg] Curve number at the diagram VKDV / VKDH Q [m3/h] VENTS. Smoke Extraction and Ventilation | Catalogue no.5 | 06-2014

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.