Catalog excerpts
Industrial and commercial ventilation (Catalogue no. 1) Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation components - fans for round and rectangular ducts, sound-insulated, axial and roof fans, air handling units with heat recovery, air heating units, accessories. Energy saving supply and exhaust units and air handling units with heat recovery with air capacity up to 6500 m3/h. Fire and smoke damper KPDU (Catalogue no. 5) Domestic ventilation (Catalogue no. 6) Fire dampers KPDU for smoke protection systems of buildings and premises....
Open the catalog to page 2Air handling units AIRVENTS (Catalogue no. 3) Energy saving air handling units with air capacity up to 40 000 m3/h, for use in large residential, industrial and commercial objects. Domestic fans (Catalogue no. 7) Domestic fans with air capacity up to 365 m3/h with extra functions: timer, humidity sensor, motion sensor, etc. Applied for premises up to 30 m2. Energy saving ventilation Geothermal systems GEO VENTS (Catalogue no. 4) Energy saving system GEO VENTS with use of the earth’s surface layers heat. High ventilation system energy efficiency and low operating costs. VENTS VN Mono-pipe...
Open the catalog to page 3VENTS. DOMESTIC FANS. CATALOGUE №7 | 05-2014
Open the catalog to page 4VENTS. DOMESTIC FANS. CATALOGUE №7 | 05-2014
Open the catalog to page 5INTELLECTUAL FANS Intellectual fan iFan iFan Move LOW-NOISE AND ENERGY-SAVING AXIAL FANS Low-noise and energy-saving axial fans VENTS Quiet Low-noise and energy-saving axial fans VENTS Silenta-S Axial inline fans VENTS VKO VENTS VKOk Low-noise and energy-saving axial fans VENTS Silenta-M AXIAL INLINE FANS Axial inline fans VENTS VKO1 VENTS VKO1k AXIAL WALL- AND CEILING-MOUNTED FANS Axial fans VENTS М Axial fans VENTS М1 Axial fans VENTS М3 Axial fans VENTS МА Axial fans VENTS X1 Axial fans VENTS F1 Axial fans VENTS K1 Axial reverse fans VENTS MA reverse Axial fans VENTS F Axial fans VENTS K...
Open the catalog to page 6Axial fans VENTS PF1 Axial fans VENTS D Axial fans VENTS S Axial decorative fans VENTS LD Auto Axial decorative fans VENTS LD Fresh time Axial decorative fans VENTS Modern Auto AXIAL DECORATIVE FANS Axial decorative fans VENTS LD Axial decorative fans VENTS LD light Axial decorative fans VENTS Modern Axial decorative fans VENTS Domino Axial decorative fans VENTS Vitro VENTS Vitro star Axial decorative fans VENTS Z VENTS Z star Axial decorative fans VENTS X VENTS X star AXIAL WINDOW FANS Axial window fans VENTS МАО1 VENTS МАО2 Axial window fans VENTS М1ОК2 Axial window reverse fans VENTS...
Open the catalog to page 7ELECTRICAL ACCESSORIES Fan control unit BU-1-60 Sensor speed switch SP3-1 Temperature regulators RTS, RTSD, RT Back valve KO series Sensor speed controller SRS-1 VENTS. DOMESTIC FANS. CATALOGUE №7 | 05-2014
Open the catalog to page 8VENTS. DOMESTIC FANS. CATALOGUE №7 | 05-2014
Open the catalog to page 9WELCOME TO THE VENTS WORLD! VENTS company was founded in the nineties of the XXth century. Dynamic development of the enterprise and ongoing study of the consumer demand enabled rapid international leadership of the company in the ventilation industry. VENTS is a powerful research and development enterprise with 2500 professionals working as a single team to ensure a full production cycle from idea to end product. The production base of the company is located at more than 60 000 m2 area. It includes 16 workshops equipped under the latest international standards and each of them is...
Open the catalog to page 10Metal processing workshop Spiral air ducts workshop Flexible air ducts workshop Aluminium grilles and diffusers workshop Powder coating workshop Extrusion workshop Injection moulding workshop Residential fans workshop Ventilation grilles workshop Electric motors workshop Industrial fans workshop Air handling units workshop AirVents air handling unit workshop Electrical accessories workshop Extruded grilles workshop Powerful production facilities, high automation level, active implementation of innovative technologies in the production process made VENTS a worldwide ventilation leader. We...
Open the catalog to page 11air intake from outside the oxygen content decreases, humidity and dustiness level increase. If exhaust ventilation is not provided or it is not effective, polluted air, smells, humidity and harmful substances are not removed. Well coordinated operation of supply and exhaust air vents is one more important factor for properly arrangement of ventilation system. In case of exhaust ventilation only (i.e. exhaust ventilation in the bathroom) air from outside flows through all possible gaps in windows, doors and walling. Such non-arranged air supply brings dust ingress, smells and drafts. The...
Open the catalog to page 12Natural and mechanical ventilation Premise type Natural ventilation requires no electric equipment such as fans or motors and is originated by natural seasonal factors as external and internal air temperature Living room drop, pressure level as a function of height, wind loading. But no matter of the season or weather natural ventilation cannot provide full-featured air exchange. tilation of periodically occupied premises but its capacity is not enough for well balanced air exchange. Mechanical ventilation devices ensure active air exchange and can operate continuously or periodically...
Open the catalog to page 13Fans are the mechanical devices that provide air motion along air ducts, direct air supply or air exhaust from the premise. Air motion is effected due to pressure drop between the fan intake and exhaust. High efficiency at low air resistance almost not audible hardly audible 25 Axial fans are the wheels with blades (so called impeller) enclosed in cylindrical casings and attached to the hub at required angle to plane of audible enough axial fan blades are fixed directly to the motor Application: air exhaust and air supply through free openings or vents or in assembly definitely audible with...
Open the catalog to page 14What is IP? While selecting the equipment and its location it is extremely important to ensure compliance of the protection rating to the operating conditions. Any electrical device must meet two protection requirements: safety for the user and operating personnel protection of the electrical components located in the device against environmental impact. IP rating refers to dust and moisture protection of the equipment and its electrical safety. Ingress protection rating marked as IP followed by two digits is stated in the technical documentation and on the equipment casing. F.e. IP20 or...
Open the catalog to page 15All Ventilation Systems JSC catalogs and technical brochures
-
MODULAR AIR HANDLING UNITS 2024
27 Pages
-
AIR HANDLING UNITS
195 Pages
-
FLEXIVENT
70 Pages
-
FIRE SAFETY DAMPERS
65 Pages
-
BOOST 355/400 USER MANUAL-EN
16 Pages
-
PLASTIVENT-EN
9 Pages
-
RECTANGULAR INLINE FANS
12 Pages
-
VK VMS 125
2 Pages
-
VENTS МА Series
2 Pages
-
VENTS Quiet Series
2 Pages
-
VENTS iFan CELSIUS
5 Pages
-
Metal grilles for HVAC
42 Pages
-
Plastic HVAC grilles
24 Pages
-
Round and flat PVC ducting
30 Pages
-
Spirally wound air ducts
50 Pages
-
VENTS iFan CELSIUS
11 Pages
-
VENTS iFan
12 Pages
-
Flexible ducts and fittings
60 Pages
-
Smoke estraction and ventilation
64 Pages
-
Domestic ventilation
373 Pages
-
Air distribution units
102 Pages