AIR HANDLING UNITS
195Pages

{{requestButtons}}

Catalog excerpts

AIR HANDLING UNITS - 2

AIR HANDLING UNITS WITH HEAT RECOVERY COMPACT HEAT RECOVERY AIR HANDLING UNITS VENTS VUT 100 P mini/VENTS VUE 100 P mini Air handling units with heat recovery Air flow – up to 100 m /h 3 VENTS VUT/VUE 250 V mini/VUT/VUE 250 H mini Air handling units with heat recovery Air flow – up to 250 m /h 3 VENTS VUT V2/H2 mini EC, VENTS VUE V2/H2 mini EC Air handling unit with heat recovery and EC motor Air flow – up to 350 m /h 3 HEAT RECOVERY AIR HANDLING UNITS IN EPP CASING VENTS VUE P3 Air handling units with heat recovery Air flow – up to 400 m3/h VENTS VUE P3B EC Air handling units with heat...

Open the catalog to page 2
AIR HANDLING UNITS - 3

AIR HANDLING UNIT WITH HEAT RECOVERY AND EC MOTOR VENTS VUT PB EC Air handling unit with heat recovery and EC motor Air flow – up to 410 m3/h VENTS VUT VB EC/VENTS VUE VB EC Air handling unit with heat recovery and EC motor Air flow – up to 690 m /h 3 VENTS VUT/VUE HB EC/VENTS VUT/VUE HBE EC Air handling units with heat recovery Air flow – up to 830 m3/h VENTS VUT PBE EC/VENTS VUT PBW EC Air handling unit with heat recovery and EC motor Air flow – up to 4300 m /h 3 VENTILATION UNITS WITH HEAT RECOVERY VENTS VUT H Air handling units with heat recovery Air flow – up to 2200 m /h 3 VENTS VUT...

Open the catalog to page 3
AIR HANDLING UNITS - 4

AIR HANDLING UNITS WITH ROTARY HEAT EXCHANGER VENTS VUTR VE EC Air handling unit with heat recovery and EC motor Air flow – up to 670 m /h 3 VENTS VUTR PE EC Air handling unit with heat recovery and EC motor Air flow – up to 710 m3/h VUTR EH EC/VUTR WH EC Air handling unit with heat recovery and EC motor Air flow – up to 2250 m /h 3 VENTS VUTR 200 V6E EC Air handling unit with heat recovery and EC motor Air flow – up to 270 m /h 3 SUPPLY UNITS, EXHAUST UNITS VENTS VPA series supply units VENTS MPA...E series supply units VENTS MPA...W series supply units VENTS PA...E series supply units...

Open the catalog to page 4
AIR HANDLING UNITS - 5

Mixing units Hydraulic U-trap Flexible connectors Control panels VENTS. Air handling units | 2023-01

Open the catalog to page 5
AIR HANDLING UNITS - 6

Electro-mechanical humidistats Electric actuator BELIMO Humidity sensor Kitchen exhaust hood VENTS. Air handling units | 2023-01

Open the catalog to page 6
AIR HANDLING UNITS - 7

VENTS. Air handling units | 2023-01

Open the catalog to page 7
AIR HANDLING UNITS - 8

WELCOME TO THE WORLD OF VENTS! Being the world's ventilation leader VENTS brand you can be confident that you have made offers a wide range of cutting-edge ventilation the right choice. Thanks to a comprehensive range equipment to satisfy most demanding customers. of ventilation equipment for home, commercial Since the inception, the company's products and industrial applications you can always find have become popular in more than 100 countries the necessary equipment and components to suit worldwide while the VENTS brand has earned your needs. The climatic engineering and design a solid...

Open the catalog to page 8
AIR HANDLING UNITS - 9

Uncompromising quality VENTS maintains a stringent quality control standard for quality management systems of system to make sure that its products always meet most demanding international standards as operates in accordance with all the applicable confirmed by numerous certificates issued by the world's largest and most reputable organisations implements new technology in order to ensure for quality control.The VENTS production process is certified according to ISO 9001:2015 international continuously environmental Following the customer's lead VENTS uses its extensive research and...

Open the catalog to page 9
AIR HANDLING UNITS - 10

What Is Ventilation? Ventilation is a set of actions and techniques used to arrange air exchange and to provide a specific air medium condition in the premises and in working places. Ventilation maintains desirable indoor climatic parameters in compliance with set hygienic norms and technology requirements. What Is Ventilation Required For? We are surrounded with air and breathe in and out 20 000 litres of air every day. How much healthy is the air we breath in? There is a range of aspects to determine air quality. Oxygen and carbon dioxide concentration in the air. Oxygen decrease and...

Open the catalog to page 10
AIR HANDLING UNITS - 11

How to determine a premise volume? Use a simple formula: Air ventilation rate: Premise Living room of apartments or hostel residential premises length x width x height = volume of the premises in cubic meters Domestic premises Example: a premise with 7 m length, 4 m width and 2.8 m height. To determine the air volume required for ventilation of this premises, calculate the room volume 7x4x2.8=78.4 m3. After that determine the required effi ciency of the fan using the following tables of reco mm ended ventilation rate. Home laundry room Theatre, cinema, confrence hall Bar, café, pub,...

Open the catalog to page 11
AIR HANDLING UNITS - 12

AIR HANDLING UNITS WITH HEAT RECOVERY Automation The VUT 300 EH EC A21 units are equipped with integrated control system. The A21 controller allows integrating the unit into the Smart Home system or BMS (Building Management Systems). Filter High degree of air purification is achieved due to G4-F7 incorporated panel type filters on metal frames. Filter size match the European Norms and Standards. Filter clogging control by means of integrated automation system as well as filter easy removal and cleaning ensure their quality and durability.   Heater: Electric heater is designed for air...

Open the catalog to page 12
AIR HANDLING UNITS - 13

Casing The casing is made of two-layers aluminum-zinc compound internally filled with the mineral wool layer for heat and sound insulation. The internal sheet is made of aluminum-zinc steel plates with varnish coating to ensure long service life. The internal galvanized steel plate provides the surface hygienic purity of the unit and disables dirt accumulation on the panel. The side panels can be easily removed for inspection and service of all the unit elements. Air supply and exhaust is effected by means of two centrifugal single-inlet EC fans equipped with forward curved blades. EC motor...

Open the catalog to page 13
AIR HANDLING UNITS - 14

AIR HANDLING UNITS WITH HEAT RECOVERY The issue of ventilation from the point of view of thermal energy saving (maintaining permanent temperature) is the most essential subject. The factors that influence the heat loss dynamics vary from wall thermal protection to heaters and heating system quality, density of wall panels joints and window joints as well as personal consumption habits. In modern buildings ventilation demands up to 45 % of the total heat energy consumption. The reasons are as follows: a) One half of air volume is exchanged through the open window within 30-60 min. During...

Open the catalog to page 14

All Ventilation Systems JSC catalogs and technical brochures

  1. FLEXIVENT

    70 Pages

  2. VK VMS 125

    2 Pages

  3. VENTS iFan

    12 Pages

  4. Domestic fans

    140 Pages