Overview: The document provides detailed technical specifications and features of eDemand Controllers and related accessories used for demand ventilation control in air conditioning systems. These controllers are designed to manage the speed of fans and ensure efficient ventilation.
Key Features & Benefits:
  • Demand ventilation control for A/C speed controllable fans.
  • Quick start-up with pre-programmed modes.
  • IP54 rated for protection against dust and water.
  • Total motor protection using thermistor connection.
  • LCD multi-function display with language options in English, German, French, and Italian.
  • CO2, temperature, and constant pressure control capabilities.
  • Manual remote speed adjuster and min/max speed limitation.
  • RS485 Modbus interface for communication.
  • Master/Slave capability via 0-10V output.
Technical Specifications:
  • Line voltage options for single and three-phase systems.
  • Interference emissions and immunity standards (EN 61000-6-3 and EN 61000-6-2).
  • Max environmental conditions: 40°C and 85% humidity without condensation.
  • Integrated SINEFILTER for noise reduction and active power factor adjustment.
Models and Dimensions:
  • Various models available for different phase and current requirements.
  • Dimensions and weight specifications provided for each model.
Accessories & Controls:
  • Auto changeover panels compatible with eDemand controllers.
  • Single and three-phase models with adjustable duty/share timer and fan failure alarm contacts.
Connection Diagrams:
  • Detailed connection diagrams for single and three-phase inverters and electronic controllers.
See more

Catalog excerpts

Heated Towel Rails-1

Accessories & Controls eDemand Controllers Electronic voltage controller Features & Benefits • Demand ventilation control for A/C speed controllable fans • Quick start-up by pre-programmed modes • IP54 Rated • Total motor protection using thermistor connection • LCD multi function display • Menu language - English, German, French, Italian • 2 x analogue input for sensors (0-10V - separate power supply required, 0-20mA) • CO2 Control • Temperature control • Constant pressure control • Manual remote speed adjuster (0-20 mA) • Min/Max speed limitation - Volume range set point adjustment • 2 x Programmable relay output - Fault Condition, master slave • Programmable 2x Digital inputs - On/ Off, external fault, manual speed control • RS485 Modbus interface • Master/Slave capability via 0-10V output Equipment/Function • Mains switch with by-pass function • Pin protection, to save user settings • Quick start up by pre-programmed modes • Max environmental conditions 40 Deg C, 85% Humidity no condensation • Readout events memory (checking Fault log) Voltage 1 Phase 1 Phase 3 Phase 3 Phase 3 Phase Interference emissions EN 61000-6-3 (unshielded motor cable) Interference immunity EN 61000-6-2 For suitability check relevant fan accessory section

 Open the catalog to page 1
Heated Towel Rails-2

eDemand Controllers Frequency Inverter 1~ to 3~ Features & Benefits • Demand ventilation control for A/C speed controllable Fans • Quick start-up by pre-programmed modes • IP54 Rated • Total motor protection using thermistor connection • LCD multi function display • Menu language - English, German, French, Italian • 2 x analogue input for sensors (0-10V - separate power supply required, 0-20mA) • CO2 Control • Temperature control • Constant pressure control • Manual remote speed adjuster (0-20 mA) • Min/Max speed limitation - Volume range set point adjustment • 2 x Programmable relay output -...

 Open the catalog to page 2
Heated Towel Rails-3

Accessories & Controls eDemand Controllers Frequency Inverter 3~ Vent-Axia Features & Benefits • Demand ventilation control for A/C speed controllable Fans • Quick start-up by pre-programmed modes • IP54 Rated • Total motor protection using thermistor connection • LCD multi function display • Menu language - English, German, French, Italian • 2 x analogue input for sensors (0-10V - separate power supply required, 0-20mA) • CO2 Control • Temperature control • Constant pressure control • Manual remote speed adjuster (0-20 mA) • Min/Max speed limitation - Volume range set point adjustment • 2 x...

 Open the catalog to page 3
Heated Towel Rails-4

eDemand Controllers Frequency Inverter 1~ Vent-Axia Features & Benefits • Demand ventilation control for A/C speed controllable Fans • Quick start-up by pre-programmed modes • IP54 Rated • Total motor protection using thermistor connection • LCD multi function display • Menu language - English, German, French, Italian • 2 x analogue input for sensors (0-10V - separate power supply required, 0-20mA) • CO2 Control • Temperature control • Constant pressure control • Manual remote speed adjuster (0-20 mA) • Min/Max speed limitation - Volume range set point adjustment • 2 x Programmable relay output...

 Open the catalog to page 4
Heated Towel Rails-5

eDemand Auto Changeover Panels Features & Benefits Connection Diagrams Single Phase Inverters for 444169, 444170 & 444171 • eDemand compatible • Single & Three Phase models • Adjustable duty/share timer • Automatic changeover (Fan Fail) • Fan failure alarm contacts L1 L1 N N Offering Demand Ventilation control for the wide range of standard AC speed controllable Twin fans, these new changeover panels have been designed to complement the new range of eDemand Controllers and are fully compatible. Speed control input is suitable for use with the following eDemand Controller ranges: • Single & Three...

 Open the catalog to page 5
Heated Towel Rails-6

Accessories & Controls Connection Diagrams Single Phase Electronic for 444164 & 444165 ...6 F1=M10 A / ...10 F1=FF20 A 1 ~ Motor with internal thermostats 2 Line voltage depending on version: 1 ~ 230 V, 5 0/60 Hz or 1 ~ 115 V, 50/60 Hz 1 ~ Motor with internal thermostats Output 0...10 V (Imax = 10mA) Input 2: 0...10 V, 0...20 mA, 4...20 mA, TF.. (KTY) Input 1: 0...10 V, 0...20 mA, 4...20 mA, TF..(KTY) Contact rating max. AC 250 V 5 A Line depending on version 1 ~ 230 V 50/60 Hz or 1 ~ 115 V 50/60 Hz 1 Three Phase Electronic for 444166, 444167 & 444168