drywall-wood framed systems
Open the catalog to page 1Section Pages Good Design Practices 15 Introduction The basic gypsum drywall assemblies described herein offer economical, quickly erected walls and ceilings on wood framing. Excellent sound attenuation at low cost is provided when gypsum panels are resiliently attached. The assemblies are likewise suitable for wall furring and exterior soffit applications. Also designed for wood-frame construction are USG Area Separation Fire Walls/Party Walls fire-rated gypsum drywall assemblies for multi-family housing (see separate System Folder SA925) and Sheetrock Brand Vinyl-Covered Gypsum Panels...
Open the catalog to page 2Fire-rated Construction Partition Applications Fire Rating Detail & Physical Data □ Insulation* □ RC-1™ Resilient Channels** Acoustical Performance Description & Test No. STC Description System Wd Stud—1/2" Sheetrock Brand gypsum panels, N/A A Firecode C core—2 x 4 16" o.c.—panels nailed 7" o.c.—1-5/8" cem ctd nails—joints fin—UL Des U317 Wd Stud—resil partition—5/8" Sheetrock Brand gypsum 50 panels, Firecode C core—2 x 4 16" or 24" o.c.—3" Thermafiber SAFB—RC-1 chan or equivalent one side spaced 24" o.c.—panels applied horizontally and att to channels-end joints back-blocked with...
Open the catalog to page 3Fire-rated Construction Partition Applications Fire Rating Detail & Physical Data □ Insulation* □ RC-1™ Resilient Channels** Acoustical Performance Description & Test No. STC Description System Wd Stud—2 layers 5/8" Sheetrock Brand gypsum N/A J panels, Firecode core, outside, both sides—5/8" Sheetrock Brand gypsum panels, Firecode core, inside, both sides—2 rows 2 x 4 24" o.c.—base layer att with 6d ctd nails 6" o.c.—face layer att with 8d ctd nails 8" o.c.—perim caulked—joints fin—UL Des U342 Stag Wd Stud—2 layers 5/8" Sheetrock Brand 47 TL-69-211 K gypsum panels, Firecode...
Open the catalog to page 4Where exceptional sound control, greater fire resistance and strength are required, double-layer drywall construction is used with Thermafiber SAFB and RC-1 Resilient Channels or equivalent applied to one side of wood studs (see table below). Sound Transmission Loss—db Reference (p. 3 & 4) Test No. Method Area Separation Fire Wall/Party Wall Fast-erecting non-load-bearing drywall partitions for low-cost fire barriers in wood-frame multi-family housing (see separate Systems Folder SA925). Wall Furring Sheetrock Brand Gypsum Panels, Foil-Back, provide an economical, efficient vapor retarder...
Open the catalog to page 5Single-Layer Application Double-Layer Application (1) A 5/8" thickness is recommended for the finest single-layer construction, providing increased resistance to fire and transmission of sound; 1/2" for singlelayer application in new residential construction and remodeling; and 3/8" for repair and remodeling over existing surfaces.(2) Long edge position relative to framing. (3) Not recommended below unheated spaces. (4) Not recommended if water-based texturing material is to be applied. (5) Max. spacing 16" if water-based texturing material is to be applied. (6) If 1/2" SHEETROCK Brand Interior...
Open the catalog to page 6Drywall/Wood Framed Systems Tub and Shower Details— Single-layer Panels Shower Receptor Double-layer panels / " or 5/8" SHEETROCK Brand gypsum panels, water resistant 1 4 /2" or 5/8" SHEETROCK Brand gypsum panels, water resistant continuous caulk Shower Receptor leveling guide /4" space wood furring continuous caulk shower base Shower Receptor Fire resistive control joints / " SHEETROCK Brand gypsum panel, FIRECODE core THERMAFIBER SAFB wood stud / " SHEETROCK Brand gypsum panel, FIRECODE core Wall control joint wood stud zinc control joint no. 093 / " SHEETROCK Brand gypsum panel, FIRECODE core...
Open the catalog to page 7Fastener load data Fastener type United States Gypsum Company SA-924
Open the catalog to page 8Drywall/Wood Framed Systems Single layer In single-layer ceiling assemblies, SHEETROCK Brand Gypsum Panels are applied across the supports and fastened with nails or screws. Nails are spaced 6Љ to 7Љ o.c. (6Љ for fire-rated construction); 1-1/4Љ Type W screws are spaced 12Љ o.c. Where no fire rating is required, adhesive nail-on fastening improves bond strength and reduces face nailing. Resilient attachment Resilient channel systems offer fire-resistant wood joist floor/ceiling assemblies having highly efficient sound isolation at low cost—qualities particularly needed in apartments, motels and other...
Open the catalog to page 9Drywall/Wood Framed Systems Insulation* RC-1™ Resilient Channels** Furring Channels*** Fire-rated Construction Fire Rating 1 hr. Detail & Physical Data 1/2Љ or 5/8Љ SHEETROCK Brand gypsum panels, FIRECODE C core, ceiling—1Љ nom wd sub & fin flr—2 x 10 wd joist 16Љ o.c.—panels att with 5d cem ctd nails 6Љ o.c. —joints fin—ULC Des L512 System Reference Resil ceiling—1/2Љ or 5/8Љ SHEETROCK Brand gypsum N/A panels, FIRECODE C core—1Љ nom wd sub & fin flr— 2 x 10 wd joist 16Љ o.c.—RC-1 chan or equivalent spaced 24Љ o.c.—panels att with 1Љ Type S screws—end joints back-blocked with RC-1 chan or equivalent—joints...
Open the catalog to page 10Drywall/Wood Framed Systems Fire-rated Construction Floor/Ceiling Assemblies Detail & Physical Data Acoustical Performance N/A 5/8Љ SHEETROCK Brand Gypsum Panels, FIRECODE core, ceiling—single 4 x 10 or double 2 x 10 wd joist 48Љ o.c.— met fur chan spaced 24Љ o.c.—panels att with 1Љ Type S screws—joints fin—UL Des L508 5/8Љ SHEETROCK Brand Gypsum Panels, FIRECODE core, 1Љ nom wd sub & fin flr—2 x 10 wd joist 16Љ o.c.—panels att with 6d nails 6Љ o.c.—joints fin—UL Des L501 Based on 1-1/4Љ | nom wd flr —CK-6412-7 Based on 1-1/4Љ nom wd flr, 44 oz carpet & 40-oz pad atop flooring —CK-6412-8 5/8Љ SHEETROCK...
Open the catalog to page 1114 Pages
7 Pages
11 Pages
17 Pages
6 Pages
4 Pages
3 Pages
2 Pages
2 Pages
300 Pages
12 Pages
24 Pages
19 Pages
2 Pages
40 Pages
2 Pages
12 Pages
1 Page
12 Pages
8 Pages
4 Pages
12 Pages
6 Pages
28 Pages
28 Pages
15 Pages
232 Pages
2 Pages
2 Pages
2 Pages
2 Pages
228 Pages
12 Pages
72 Pages
60 Pages
4 Pages
196 Pages
32 Pages
108 Pages
330 Pages
40 Pages
4 Pages