Introduction
The document discusses the use of gypsum drywall assemblies for efficient wall and ceiling construction on wood framing. These systems offer excellent sound attenuation and are suitable for wall furring and exterior soffit applications. Variations include single and double-layer systems, with methods to enhance job quality.
Specifications
  • Single Layer Systems: Utilizes SHEETROCK Brand Gypsum Panels applied directly to wood framing with various fastening methods including nailing, screwing, and adhesive application.
  • Double Layer Systems: Features a face layer of gypsum panels laminated to a base layer for increased strength, fire, and sound resistance.
Fire-Rated Construction
Details systems with fire ratings from 45 minutes to 2 hours using SHEETROCK Brand Gypsum Panels and THERMAFIBER SAFB insulation, suitable for partition and exterior wall applications.
Acoustical Performance
Provides sound transmission loss data for different systems, tested in labs with specific STC ratings to indicate sound isolation effectiveness.
Good Design Practices
Recommends using Type S screws, ensuring proper attachment of resilient channels, and avoiding exposure to moisture and temperature extremes. Special panels are advised for high moisture areas.
Architectural Specifications
Includes details on panel availability, limitations, and maximum support spacing, emphasizing adherence to installation methods for desired fire and sound ratings.
Procedures
Installation guidelines cover ceiling and floor attachments, sound-isolating partitions, and corner framing details, with specific instructions for using SHEETROCK Brand gypsum panels in various configurations.
Standards and Testing
References tests and standards like Test TL-77-149 for sound-isolating chase wall partitions and WH-651-0318.1 for fire resistance ratings.
Recommendations
Advises using adhesive for laminating 3/8" boards for double-layer ceilings and proper spacing for fire ratings. Recommends THERMAFIBER SAFB for insulation and RC-1 Resilient Channels for sound isolation.
Fire-rated Construction and Acoustical Performance
Describes floor/ceiling assemblies with fire ratings and acoustical performance metrics like STC and IIC ratings, using combinations of SHEETROCK Brand gypsum panels, resilient channels, and insulation materials.
Key Data from Tables and Diagrams
Includes fastener load data specifying allowable withdrawal and shear resistance, with diagrams illustrating construction details for various assemblies.
Framing Supports
  • Single Nailing Method: Nails spaced 7 inches o.c. for ceilings and 8 inches o.c. for walls.
  • Adhesive Application: Uses drywall stud adhesive with immediate fastener application.
  • Double-Nailing Method: Nails spaced 12 inches o.c. with a second nail 2 inches away.
  • Power-Driven Screws: 1-1/4 inch Type W screws spaced 16 inches o.c. for walls and 12 inches o.c. for ceilings.
  • Vinyl Foam Tape: Uses adhesive and tape strips as per manufacturer’s directions.
SHEETROCK Brand Gypsum Panels, Water-Resistant, Erection
  • Framing: Ensure studs are flush with the panel face and install necessary blocking for fixtures.
  • Gypsum Panels: Installed perpendicular with specific fastener spacing, optional adhesive for tiles up to 5/16 inch thick.
  • Joint Treatment: Use SHEETROCK Brand compounds for treating fastener heads and joints.
Floating Interior Angle System
Apply ceiling panels first, ensuring firm support, with fasteners at specified distances from intersections.
Base Layer Erection—Direct Attachment
  • Ceilings: Panels applied perpendicular or parallel to framing with specific joint offsets.
  • Sidewalls: Panels applied with long edges centered on framing members.
Face Layer Erection—Direct Attachment
Use maximum length panels to minimize joints, with adhesive for lamination and temporary supports until bond develops.
Resilient Channel Erection
Channels positioned at right angles to framing and attached with screws, with specific instructions for placement and attachment.
Gypsum Panel Erection—Ceilings
  • Base Layer: Panels applied with staggered joints and attached with nails and screws.
  • Face Layer: Panels applied perpendicular to channels with specific fastener spacing.
USG High Performance Floor/Ceiling System
  • Floor: Plywood sheets applied with specific fastener spacing, followed by gypsum liner panels and floor finishing.
  • Cavity: Insulation installed between joists with support rods.
  • Ceiling: Resilient channels and gypsum panels applied with specific fastener spacing and joint treatment.
Gypsum Panel Erection—Walls
Panels applied with resilient channels and fastened with screws, with instructions for two-layer applications.
Single-Layer Application—Direct Attachment
Wood furring strips spaced and attached to masonry walls, with gypsum panels applied perpendicular to the strips.
Specifications and Procedures
1. Type W Screws and Foil-Back Panels: Use Type W screws spaced 16 inches o.c. for foil-back panels, with asphalt felt strip in water-prone areas.
2. Mechanical Application with Z-Furring Channels: Insulation erected vertically on masonry walls, held with Z-Furring Channels spaced 24 inches o.c.
3. Sheathing Application: Apply sheathing horizontally or vertically with specific nail spacing.
4. Exterior Ceilings and Soffits: Apply SHEETROCK Brand Exterior Gypsum Ceiling Board with specified joint finishing.
5. Joint System: Prefill grooves with joint compound, apply tape, and finish with embedding coats.
6. Corner Bead and Trim: Reinforce corners with corner bead and apply joint compound.
7. Control Joints: Break panels and channels behind joints, apply sealant, and attach control joints.
Metric Conversion
Provides metric equivalents for USG product dimensions, with conversion factors and notes on availability.
Safety and Liability
Emphasizes safety practices during handling and installation, limiting liability to replacement of defective goods.
Trademarks
Lists trademarks owned by United States Gypsum or related companies.
See more

Catalog excerpts

Drywall-Wood Framed Systems-1

drywall-wood framed systems

 Open the catalog to page 1
Drywall-Wood Framed Systems-2

Section Pages Good Design Practices 15 Introduction The basic gypsum drywall assemblies described herein offer economical, quickly erected walls and ceilings on wood framing. Excellent sound attenuation at low cost is provided when gypsum panels are resiliently attached. The assemblies are likewise suitable for wall furring and exterior soffit applications. Also designed for wood-frame construction are USG Area Separation Fire Walls/Party Walls fire-rated gypsum drywall assemblies for multi-family housing (see separate System Folder SA925) and Sheetrock Brand Vinyl-Covered Gypsum Panels...

 Open the catalog to page 2
Drywall-Wood Framed Systems-3

Fire-rated Construction Partition Applications Fire Rating Detail & Physical Data □ Insulation* □ RC-1™ Resilient Channels** Acoustical Performance Description & Test No. STC Description System Wd Stud—1/2" Sheetrock Brand gypsum panels, N/A A Firecode C core—2 x 4 16" o.c.—panels nailed 7" o.c.—1-5/8" cem ctd nails—joints fin—UL Des U317 Wd Stud—resil partition—5/8" Sheetrock Brand gypsum 50 panels, Firecode C core—2 x 4 16" or 24" o.c.—3" Thermafiber SAFB—RC-1 chan or equivalent one side spaced 24" o.c.—panels applied horizontally and att to channels-end joints back-blocked with...

 Open the catalog to page 3
Drywall-Wood Framed Systems-4

Fire-rated Construction Partition Applications Fire Rating Detail & Physical Data □ Insulation* □ RC-1™ Resilient Channels** Acoustical Performance Description & Test No. STC Description System Wd Stud—2 layers 5/8" Sheetrock Brand gypsum N/A J panels, Firecode core, outside, both sides—5/8" Sheetrock Brand gypsum panels, Firecode core, inside, both sides—2 rows 2 x 4 24" o.c.—base layer att with 6d ctd nails 6" o.c.—face layer att with 8d ctd nails 8" o.c.—perim caulked—joints fin—UL Des U342 Stag Wd Stud—2 layers 5/8" Sheetrock Brand 47 TL-69-211 K gypsum panels, Firecode...

 Open the catalog to page 4
Drywall-Wood Framed Systems-5

Where exceptional sound control, greater fire resistance and strength are required, double-layer drywall construction is used with Thermafiber SAFB and RC-1 Resilient Channels or equivalent applied to one side of wood studs (see table below). Sound Transmission Loss—db Reference (p. 3 & 4) Test No. Method Area Separation Fire Wall/Party Wall Fast-erecting non-load-bearing drywall partitions for low-cost fire barriers in wood-frame multi-family housing (see separate Systems Folder SA925). Wall Furring Sheetrock Brand Gypsum Panels, Foil-Back, provide an economical, efficient vapor retarder...

 Open the catalog to page 5
Drywall-Wood Framed Systems-6

Single-Layer Application Double-Layer Application (1) A 5/8" thickness is recommended for the finest single-layer construction, providing increased resistance to fire and transmission of sound; 1/2" for singlelayer application in new residential construction and remodeling; and 3/8" for repair and remodeling over existing surfaces.(2) Long edge position relative to framing. (3) Not recommended below unheated spaces. (4) Not recommended if water-based texturing material is to be applied. (5) Max. spacing 16" if water-based texturing material is to be applied. (6) If 1/2" SHEETROCK Brand Interior...

 Open the catalog to page 6
Drywall-Wood Framed Systems-7

Drywall/Wood Framed Systems Tub and Shower Details— Single-layer Panels Shower Receptor Double-layer panels / " or 5/8" SHEETROCK Brand gypsum panels, water resistant 1 4 /2" or 5/8" SHEETROCK Brand gypsum panels, water resistant continuous caulk Shower Receptor leveling guide /4" space wood furring continuous caulk shower base Shower Receptor Fire resistive control joints / " SHEETROCK Brand gypsum panel, FIRECODE core THERMAFIBER SAFB wood stud / " SHEETROCK Brand gypsum panel, FIRECODE core Wall control joint wood stud zinc control joint no. 093 / " SHEETROCK Brand gypsum panel, FIRECODE core...

 Open the catalog to page 7
Drywall-Wood Framed Systems-8

Fastener load data Fastener type United States Gypsum Company SA-924

 Open the catalog to page 8
Drywall-Wood Framed Systems-9

Drywall/Wood Framed Systems Single layer In single-layer ceiling assemblies, SHEETROCK Brand Gypsum Panels are applied across the supports and fastened with nails or screws. Nails are spaced 6Љ to 7Љ o.c. (6Љ for fire-rated construction); 1-1/4Љ Type W screws are spaced 12Љ o.c. Where no fire rating is required, adhesive nail-on fastening improves bond strength and reduces face nailing. Resilient attachment Resilient channel systems offer fire-resistant wood joist floor/ceiling assemblies having highly efficient sound isolation at low cost—qualities particularly needed in apartments, motels and other...

 Open the catalog to page 9
Drywall-Wood Framed Systems-10

Drywall/Wood Framed Systems Insulation* RC-1™ Resilient Channels** Furring Channels*** Fire-rated Construction Fire Rating 1 hr. Detail & Physical Data 1/2Љ or 5/8Љ SHEETROCK Brand gypsum panels, FIRECODE C core, ceiling—1Љ nom wd sub & fin flr—2 x 10 wd joist 16Љ o.c.—panels att with 5d cem ctd nails 6Љ o.c. —joints fin—ULC Des L512 System Reference Resil ceiling—1/2Љ or 5/8Љ SHEETROCK Brand gypsum N/A panels, FIRECODE C core—1Љ nom wd sub & fin flr— 2 x 10 wd joist 16Љ o.c.—RC-1 chan or equivalent spaced 24Љ o.c.—panels att with 1Љ Type S screws—end joints back-blocked with RC-1 chan or equivalent—joints...

 Open the catalog to page 10
Drywall-Wood Framed Systems-11

Drywall/Wood Framed Systems Fire-rated Construction Floor/Ceiling Assemblies Detail & Physical Data Acoustical Performance N/A 5/8Љ SHEETROCK Brand Gypsum Panels, FIRECODE core, ceiling—single 4 x 10 or double 2 x 10 wd joist 48Љ o.c.— met fur chan spaced 24Љ o.c.—panels att with 1Љ Type S screws—joints fin—UL Des L508 5/8Љ SHEETROCK Brand Gypsum Panels, FIRECODE core, 1Љ nom wd sub & fin flr—2 x 10 wd joist 16Љ o.c.—panels att with 6d nails 6Љ o.c.—joints fin—UL Des L501 Based on 1-1/4Љ | nom wd flr —CK-6412-7 Based on 1-1/4Љ nom wd flr, 44 oz carpet & 40-oz pad atop flooring —CK-6412-8 5/8Љ SHEETROCK...

 Open the catalog to page 11

All USG catalogs and technical brochures

  1. Transportation

    14  Pages

  2. Healthcare

    7  Pages

  3. Workspace

    11  Pages

  4. Education

    17  Pages

Archived catalogs

  1. System catalog

    12  Pages

  2. USG EcoFix™

    2  Pages

  3. USG Floor Prep

    12  Pages

  4. WALL PREP

    28  Pages

  5. ROOFING

    28  Pages

  6. WALLBOARD

    15  Pages

  7. Frost? Frost

    2  Pages

  8. Aspen

    2  Pages

  9. Glacier

    2  Pages

  10. CEILING SYSTEMS

    196  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.