Product Identification and Contact Information

The ORY AP 800 2F is a residential heating appliance brand under Ungaro, manufactured in Italy with contact details provided for two locations: San Mango d’Aquino (CZ) and Montebello Vicentino (VI).

Certification and Compliance

  • Certified according to EN 14785:2006 standard.
  • Notified Body: IMQ S.p.A. (NB. N° 0051).
  • Test report reference: CS24-0112987-01.
  • Declaration of Performance (D.O.P.) Number: OAP82F.

Product Description

The appliance is designed for residential space heating using wood pellets as fuel, without hot water production. It is classified as a 4-star environmental quality product under Italian Decree n°186 (7/11/2017).

Energy Efficiency and Environmental Performance

  • Energy Efficiency Index (EEI): 120.
  • Energy Efficiency Class: A+.
  • Seasonal space heating energy efficiency: 79.2%.
  • Recommended fuel: Wood pellets compliant with EN ISO 17225-2 class A1.

Control Features

  • Electronic room temperature control with weekly timer.
  • Optional remote control available (WiFi).

Technical Specifications

ParameterNominalReduced
Heat Input (kW)16.57.3
Heat Output (kW)156.9
Power to Air (kW)156.9
Efficiency (%)90.893.7
Hourly Consumption (kg/h)3.61.6
Autonomy (hours)1738
Mean Flue Gas Temperature (°C)15487
Mean CO Emission (13% O2) (%)0.0110.005
Mean CO Emission (mg/Nm3)13758
Mean Dust Emission (mg/Nm3)1530
Mean OGC Emission (mg/Nm3)86
Mean NOx Emission (mg/Nm3)144120
Flue Gas Mass Flow Rate (g/s)11.37.3
Electrical Consumption (W)150 (Start 470, Standby 3)74

Physical and Installation Parameters

  • Electrical supply: 230 V - 50 Hz.
  • Minimum chimney draft: 10-11 Pa (0.10-0.11 mbar).
  • Pellet feed box capacity: 60 kg.
  • Net weight: 185 kg.
  • Heating fan airflow: 250 + 160 + 160 m3/h.
  • Sealed combustion chamber.

Safety and Clearance Distances

  • Minimum distance from combustible materials: Left and Right sides 340 mm, Rear 290 mm, Front 1000 mm, Floor 120 mm.
  • Minimum distance between side panels and heating body: 30 mm.
  • Minimum ventilation grid area: 550 cm².
  • Maintenance access opening required: 1706 x 550 mm on the side of the electronic control unit.

Air and Flue Gas Connections

  • Air intake pipe diameter: 80 mm.
  • Flue gas exhaust pipe diameter: 100 mm.
  • Hot air ducting diameter: 80 mm with maximum ducting length of 5 meters.
  • Hot air outlet options: front and ducted.
  • Minimum convective air inlet and outlet section: 450 cm² each.

Instructions and Recommendations

Users must read and follow the instruction manual carefully to ensure proper installation, operation, and maintenance of the appliance.

See more

Catalog excerpts

ORY AP 800 2f (Air)-1

ORY AP 800 2F SCHEDA TECNICA TECHNICAL SHEET FICHE TECHNIQUE TECHNISCHES BLATT FICHA TECNICA DATA PAPIER Tutti i diritti sono riservati. Le immagini e i dati contenuti nella presente edizione sono puramente indicativi e non vincolanti. L’Artistico si riserva il diritto di modifi care in ogni momento dati e informazioni. All rights reserved. The images and data contained in this edition are purely indicative and non-binding. L’Artistico reserves the right to modify data and information at any time. Tous droits réservés. Les images et données contenues dans cette édition sont purement indicatives et non contraignantes. L’Artiste se réserve le droit de modifi er à tout moment les données et informations. Todos los derechos reservados. Las imágenes y los contenidos de la presente edición son puramente indicativos y no vinculantes. L’Artistico se reserva el derecho de modifi car los datos e información en cualquier momento. Via San Mango due 88040 SAN MANGO D’AQUINO (CZ) ITALY [email protected] TEL +39 0968 926838 / +39 0968 926857 Whatsapp +39 0968 96484 (Assistenza) FAX +39 0968 926861 Via del Progresso, 51 36054 MONTEBELLO VICENTINO (VI) ITALY [email protected] TEL +39 0444 440963 FA

 Open the catalog to page 1
ORY AP 800 2f (Air)-2

Combustibile raccomandato / Recommended fuel / Combustible recommande / Empfohlener Kraftstoff / Combustible recomendado / Aanbevolen brandstof ORY AP 800 2F Informazioni marcatura / Marking information / Informations certification / Prufungsinformation / Informacion de marcado / Markeerinfor-matie Ente Notificato / Notified Body / Institut notifie / Benanntes Labor / Entidad autorizada / Aangemelde instantie Marchio commerciale / Trademark / Marque de commerce / Marke / Marca comercial / Merk Modello e tipo / Model and type / Modele et type / Model und Typ / Modelo y tipo / Modell en type Apparecchio...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About ArchiExpo
ArchiExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. ArchiExpo is an entity of VirtualExpo Group.