1. Catalogs
  2. UAB Konveka
  3. TRENCH HEATERS FCH

TRENCH HEATERS FCH

TRENCH HEATERS FCH
1 / 15 PagesView full catalog

TRENCH HEATERS FCH

Product catalog summary
Overview: The document details the specifications and features of FCH trench heaters, designed for both heating and cooling. Available in 10 models, these heaters feature stainless steel casings and come in 2 and 4 pipe versions. They are equipped with EC type motors for fans, ensuring low noise and high efficiency, and are compatible with heat pumps and condensing boilers, operating at a maximum pressure of 25 bar.
Specifications: The heaters include copper-aluminium heat exchangers, safe 24V DC fan voltage, and standard supply air filters. They are tested according to EN16430 standards and come with a 10-year warranty for casings and heat exchangers. A single room thermostat can control up to 30 units.
Design and Installation: FCH heaters are integrated into the floor, allowing for free passage and aesthetic integration with interior designs. They feature reinforced casings with soundproofing elements and adjustable height for installation in raised floors, designed to create an effective warm air curtain for large windows.
Technical Data: Detailed technical data for FCH2 and FCH4 models include dimensions, fan speed, heat outputs, cooling capacity, and sound levels. Available lengths range from 1200 to 3000 mm, with a width of 320 mm and a height of 130 mm.
Accessories and Controls: Accessories include thermostatic valves, lockshield valves, room thermostats, and electric control boxes, facilitating precise temperature management and energy efficiency.
Conclusion: FCH trench heaters are robust, efficient, and versatile solutions for heating and cooling, suitable for various building types and compatible with modern energy systems, ensuring long-term reliability and performance.
Control and Electrical Specifications: The control system is based on the Master-Slave principle, with fan speed controlled by a room thermostat using a 0-10 V signal at 24VDC. Valve actuators are controlled ON/OFF by the room thermostat at 24VDC. A single room thermostat can control up to 30 trench heaters.
Electrical Connection: The power supply is 100-240VAC, 50/60Hz, with an electrical connection diagram provided for trench heaters (FCH2), detailing connections for fan and valve actuators.
Grilles: The document describes aluminium and wooden roll-up grilles. Aluminium grilles are made from anodized aluminium with reinforced reversible double T profiles, while wooden grilles are made from solid wood, both including spacers made from anodized aluminium that resist UV or heat exposure.
About Konveka: Konveka, established in 2005, is known for high-quality and reliable convectors, offering a 5-10 year warranty on products (excluding electrical parts). Their products are verified by independent laboratories and used in prestigious buildings worldwide, emphasizing customer satisfaction and technical excellence.
See more

Catalog excerpts

TRENCH HEATERS FCH-1

TRENCH HEATERS FCH FOR HEATING FOR COOLING FAN ASSISTED • 10 models • Stainless steel casings • 2 and 4 pipes versions • Wet cooling and dry cooling ready • Tested according to EN16430 in independent accredited laboratory • 10 year warranty for casings and heat exchangers • Fans with most economical and quiet EC type motors • High rise of cooled air • Excelent compatibility with heat pumps and condensate boilers • Max operating pressure 25 bar • Possibility to control up to 30 units with 1 room thermostat • Highly efficient and economic copper– alu inium heat exchangers m • Safe voltage of fans – 24V (DC) • Supply air filters are in standard set • Reversible reinforced profile grilles • All fixing brackets and bolts have sound proofing elements • Possibility to change level of casing at any time during exploitation (when installed in raised floors)

 Open the catalog to page 1
TRENCH HEATERS FCH-2

TRENCH HEATERS FCH FCH are among the most powerful trench heaters designed for heating and cooling. Both heated and cooled air is raised right up the ceiling to result in an even distribution throughout the room. 4 and 2 pipe connection versions are available. The 4 pipe connection guarantees maximum flexibility, whereas the 2 pipe connection will ensure the maximum capacity. The air flow passing through the appliance is continuously filtered to trap a considerable part of the dust and dirt in the room and protect the heater from contamination. Include drain pans that allow the device to operate...

 Open the catalog to page 2
TRENCH HEATERS FCH-3

Especially quiet operation We have achieved exceptionally low noise levels using extremely quiet EC fans and by the optimisation of their rotational speed and design of the devices. Tested according to EN16430 The outputs of all products manufactured by Konveka have been tested by independent accredited laboratories according to the latest standards. With us, 1 kW means 1 kW. All body parts are made of stainless steel Stainless steel provides 100% corrosion protection for an indefinite time. It is also 54% stronger and 45% harder than carbon steel, so it can withstand loads during transportation,...

 Open the catalog to page 3
TRENCH HEATERS FCH-4

Stainless steel casing Brackets for heat exchanger Hydraulic connections cover Casing’s stiffening elements Copper - aluminium heat exchanger Height adjustment and vertical load supporting bolts Noise isolating elements for adjusting screws Casing fixing to the floor brackets Noise isolation elements for floor brackets 19 Pipe sealing and protection elements Cable sealing and protection elements Plugs for unused casing holes Heat exchanger fixing - protecting elements Anodized aluminium frame; colour matches the colour of grille Protective - decorative grille (optional) All fasteners required...

 Open the catalog to page 4
TRENCH HEATERS FCH-6

TECHNICAL DATA Length Width Height = installation height Type of fan motors Fan operating voltage Fan speed control voltage Thread of hydr. connections G 1/2“ Thread type of hydr. connections inner FCH4 115 Position of the hydr. connections 1 side FCH2 matmenys.idw A3 1 : 4,5 1 / 1 Operating pressure 25 bar Operating temperature 2 - 120°C Designed by EN16430 certified outputs Heat outputs, W Fan speed 75/65/20°C Sound levels Sound Sensible cooling capacity, W 14/17/25°C pressure power Δt = 9,5°C level, lev

 Open the catalog to page 6
TRENCH HEATERS FCH-7

Heat outputs, W Fan speed 75/65/20°C Sensible cooling capacity, W 14/17/25°C pressure power Δt = 9,5°C level, level, Length of heat exchanger, mm Sound levels EXAMPLE OF CONNECTIONS WINDOW SIDE 1 2 Thermostatic valve, straight Thermostatic valve actuator Straight lockshield valve INSTALLATION FEATURES • Side with heat exchanger is always mounted closer to the window (wall) • Energy carrier supply pipes has to be connected to heat exchangers connectors which are further from the fans • Energy carrier outlet pipes has to be connected to heat exchangers connectors which are closer to the fans •...

 Open the catalog to page 7
TRENCH HEATERS FCH-8

TECHNICAL DATA Length Width Height = installation height Type of fan motors Fan operating voltage Fan speed control voltage Thread of hydr. connections G 1/2“ Thread type of hydr. connections inner FCH4 115 Position of the hydr. connections 1 side FCH4 matmenys.idw A3 1 : 4,5 1 / 1 Operating pressure 25 bar Operating temperature 2 - 120°C Designed by EN16430 certified outputs Heat outputs, W Fan speed 75/65/20°C Sound levels Sound Sensible cooling capacity, W 14/17/25°C pressure power Δt = 9,5°C level, lev

 Open the catalog to page 8
TRENCH HEATERS FCH-9

Sensible cooling capacity, W Length of heat exchanger, mm Sound levels Sound Water volume, l Heating 14/17/25°C pressure power Δt = 9,5°C level, level, WINDOW SIDE Thermostatic valve, straight Thermostatic valve actuator Straight lockshield valve INSTALLATION FEATURES • The side with the heat exchanger is always mounted closer to the window (wall) • Possibility to connect pipes through the side or end of the convector • The 4-pipe heat exchanger has two independent circuits. They are connected to the heating and cooling systems on both sides of the device as follows: - To a cooling system – on...

 Open the catalog to page 9
TRENCH HEATERS FCH-10

ACCESSORIES THERMOSTATIC VALVE TVS15 Controls flow of energy carrier. Controled by thermal actuator TA24 LOCKSHIELD VALVE (STRAIGHT) LS15 Opens, closes or limits flow of energy carrier Controls flow with thermoelectric actuator For energy carrier opening, closing and presetting of maximal flow Provides possibility to close flow and disconnect heat exchanger from heating system without draining Provides possibility to close flow and disconnect heat exchanger from heating system without draining LOCKSHIELD VALVE (ANGLE) LA15 ACCESSORIES Opens, closes or limits flow of energy carrier THERMOSTATIC...

 Open the catalog to page 10
TRENCH HEATERS FCH-11

CONNECTING ONE FCH TO ROOM THERMOSTAT ROOM THERMOSTAT RTB24 THERMOSTATIC VALVE ACTUATOR TA24 CONNECTING MULTIPLE FCH TO ROOM THERMOSTAT TRENCH HEATERS FCH (UP TO 30 PCS) EL. DIAGRAMS THERMOSTATIC VALVE ACTUATORS TA24 WIRING DIAGRAM ELECTRICAL CONNECTION DIAGRAM OF TRENCH HEATERS FCH2 Heat. valve Cool. valve VALVE ACTUATOR • Trench heaters installed in the same room are controlled based on the Master - Slave principle • Speed of fans are controlled 0-10 V by room thermostat. Voltage – 24VDC Heat. valve Cool. valve ROOM THERMOSTAT 0V Y50 YH YC SLAVE TRENCH HEATER • Valve actuators are controlled...

 Open the catalog to page 11

All UAB Konveka catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.