Catalog excerpts
HEALTHCARE FOR LIFE IN HEALTHCARE The definitive product guide to meeting your HTM 64 requirements
Open the catalog to page 1TWYFORD BATHROOMS THEESSENTIALCHOICE FORCOMPLETEHTM64 COMPLIANCE With so much at stake, why take risks? Specify Twyford every time - for complete compliance and total peace of mind. The healthcare sector is one of the most challenging environments facing any specifying professional. It’s a sector where issues of hygiene, flexibility and regulatory compliance are as important as product quality and durability. Twyford’s healthcare range has been specifically designed following extensive research into the needs of healthcare managers and specifying professionals. It combines innovation with...
Open the catalog to page 2Contents WCs P5 Washbasins P8 Urinals/Bidets P11 Disposal Units P12 Sinks/Troughs P16 Stainless Steel Sinks P18 Janitorial Unit P21 Brassware P22 Traps & Wastes P28 Case Study P30 Quick Reference Table P32 SpecMaster P34 Stoke Mandeville Hospital, Buckinghamshire Contractor: Haden Young Addenbrooks Hospital, Cambridge Contractor: Haden Young St Helens & Whiston Hospitals, Merseyside Contractor: Taylor Woodrow Taylor Woodrow is now part of Vinci Construction UK Ltd North Middlesex University Hospital Contractor: Bouyges 3
Open the catalog to page 3THEPRODUCTRANGE AN EASY REFERENCE GUIDE TO ALL OUR HTM 64 COMPLIANT PRODUCTS HTM 64 Requirements Putting emphasis on the prevention of infection, the Department of Health HTM 64 provides regulatory guidance on the design, application and specification of sanitary assemblies in health buildings. Twyford Solutions The Twyford healthcare range is fully compliant to all regulations, and indeed exceeds national standards. We offer the complete solution for every healthcare application - in terms of product design and quality, installation and maintenance. SpecMaster, our print and online...
Open the catalog to page 4WC WC For fully ambulant and ambulant disabled users. For fully ambulant and ambulant disabled users. CODE: WC H CODE: WC H TYPICAL HTM 64 WC REQUIREMENTS TYPICAL HTM 64 WC REQUIREMENTS - Rimless pan for all back-to-wall hospital pattern pans - Rimless pan for all back-to-wall hospital pattern pans - Fully enclosed seat holes - Fully enclosed seat holes - Seat ring only - Seat ring only - WC suite to fully comply with the WC suite Performance Specifications of the Water Supply (Water fittings) Regulations 1999 - WC suite to fully comply with the WC suite Performance Specifications of the...
Open the catalog to page 5WC WC For assisted ambulant disabled/wheelchair users. For assisted ambulant disabled/wheelchair users. CODE: WC HD CODE: WC HD TYPICAL HTM 64 WC REQUIREMENTS TYPICAL HTM 64 WC REQUIREMENTS - Rimless pan for all back-to-wall hospital pattern pans - Rimless pan for all back-to-wall hospital pattern pans - 475 - 480mm height and 700mm projection - 475 - 480mm height and 700mm projection - Fully enclosed seat holes - Fully enclosed seat holes - Seat ring only - Seat ring only - WC suite to fully comply with the WC suite Performance Specifications of the Water Supply (Water fittings)...
Open the catalog to page 6Twyford’s healthcare range enables specifiers to completely satisfy sanitaryware requirements and regulations, across all areas of the healthcare market. SPECIFICATION MANUAL OR LOG ON TO WWW.SPECMASTERONLINE.COM 7
Open the catalog to page 7WASHBASIN WASHBASIN For use in all clinical areas. For use with concealed services; use with wall mounted supply fittings. For use in areas other than clinical areas. For use with concealed services. CODE: LB H M CODE: LB G L TYPICAL HTM 64 WASHBASIN REQUIREMENTS TYPICAL HTM 64 WASHBASIN REQUIREMENTS - Hospital pattern basin integral back outlet - General basin for use with plug and chain with screw stay - No plug, tap hole or overflow - No overflow - Connection to concealed services - No chainstay hole - Lever action integral TMV3 D08 approved thermostatic or automatic sensor controlled...
Open the catalog to page 8WASHBASIN HANDRINSE BASIN For use in areas other than clinical areas. For use with concealed services. For use other than for clinical procedures or personal washing. For use with concealed services. CODE: LB G M CODE: LB G S TYPICAL HTM 64 WASHBASIN REQUIREMENTS TYPICAL HTM 64 HANDRINSE BASIN REQUIREMENTS - General basin for use with plug and chain with screw stay - No overflow - General basin for use with plug and chain with screw stay - No chainstay hole - No overflow - Right hand tap hole or 2 tap hole - No chainstay hole - Handrinse basin only - Right hand tap hole or 2 tap hole...
Open the catalog to page 9Why risk specifying any other? With Twyford you can enjoy complete peace of mind about quality and compliance. 10 FOR FULL SPECIFICATION ON THESE PRODUCTS LOOK IN SPECMASTER
Open the catalog to page 10URINAL BIDET For use with concealed services. Back-to-wall pedestal bidet and sensor-operated spout. CODE: UR H 1/2/3 CODE: BD H TYPICAL HTM 64 URINAL REQUIREMENTS TYPICAL HTM 64 BIDET REQUIREMENTS - Wall mounted single, double or triple urinal - Hospital pattern bidet with flush grated waste - Concealed trap and for mounted in duct - Rimless - One tap hole - No overflow & no plug - With sensor operated TMV3 controlled brassware TWYFORD SOLUTION - Spectrum bowl urinal TWYFORD SOLUTION VC7004WH - Sola hospital bidet BD H, 1 tap hole SA3521WH SR8096XX - 11⁄4" grid waste (WT1) WF4341CP - 4.5...
Open the catalog to page 11Twyford have invested heavily in continuous product development and innovation in the healthcare market. DISPOSAL UNIT For disposal of liquid and solid waste. For use with concealed services: use with wall mounted supply fittings. CODE: DU TYPICAL HTM 64 DISPOSAL UNITS REQUIREMENTS - Hospital pattern disposal unit - Without drainer - No tap holes TWYFORD SOLUTION - 600x600x300mm stainless steel hopper, back inlet, no grid (DU) SS8112SS - 600x600x300mm stainless steel hopper, back inlet SS8110SS - 600x670x300mm stainless steel hopper, top inlet SS8109SS Back Inlet Hopper - Concealed cistern,...
Open the catalog to page 12DISPOSAL UNIT For disposal of liquid and solid waste. For use with concealed services: use with wall mounted supply fittings. CODE: DU H TYPICAL HTM 64 DISPOSAL UNITS REQUIREMENTS - Hospital pattern disposal unit - No tap holes TWYFORD SOLUTION - 1000x600mm stainless steel hopper with left hand drainer, right hand hopper, top inlet SS8101SS Top Inlet Hopper - 1000x600mm stainless steel hopper with left hand drainer, right hand hopper, back inlet SS8102SS - Vitreous china high level 6 litre cistern, complete with valveless fittings and chain pull - Cistern support brackets SR1300XX -...
Open the catalog to page 13All Twyford Bathrooms catalogs and technical brochures
-
AV4915BE
1 Pages
-
SR5906GY
1 Pages
-
SR5906BE
1 Pages
-
OT4242WH
1 Pages
-
OT4241WH
1 Pages
-
SF5357CP
1 Pages
-
Collection. Jump in.
120 Pages
-
New Products Brochure 2016
52 Pages
-
Exciting Developments
200 Pages
-
Showering Collection
72 Pages
-
Beautiful Baths
6 Pages
-
All inclusive living.
20 Pages
-
Exciting development
200 Pages
-
Exciting stuff.
120 Pages
-
New
52 Pages
-
Urinals
13 Pages
-
Water Saving
6 Pages
-
Commercial product Guide
161 Pages
-
Alcona
4 Pages
-
Opal Baths Leaflet
2 Pages
-
VARICOR
6 Pages
-
All - Inclusive Living 2013
16 Pages
-
Rimfree - Lift the lid
13 Pages
-
for life 2013
232 Pages
-
Outfit Showering
16 Pages
-
For Life In Education
12 Pages
-
Hotel Life
52 Pages
-
Developing Bathrooms For Life
52 Pages
-
RIMFREE
12 Pages
-
FOR LIFE IN BATHROOM
128 Pages
-
SHOWERING BROCHURE
108 Pages