  • Step 1: Remove all packaging from the umbrella and lay it flat on a soft surface to prevent damage.
  • Step 2-5: Remove screws and brackets from the heater arms and mount them using the saved screws with Loctite applied.
  • Step 6-8: Unlock the umbrella, level the stem, and secure it with the beauty cover and cam lock handles.

Operation Instructions
  • Powering On: Plug the power cord into a 220V receptacle. The control panel will light up when powered.
  • Opening and Closing: Use the control panel buttons to open or close the umbrella. Ensure the umbrella is level to operate safely.
  • Lighting and Heating: Turn on the Ambia LED light and heaters using the respective buttons. The heaters have an automatic turn-off feature after 2 hours.

Safety and Maintenance
  • Read the entire manual before use and adhere to all safety warnings.
  • Disconnect power during inclement weather and ensure proper grounding.
  • Keep children away from power cords and allow heaters to cool before closing the umbrella.
  • Ensure adequate space for operation and have electrical connections installed by a certified electrician.

Technical Specifications
  • Power Supply: 208-240VAC, 50/60 Hz, with specific requirements for North America and Europe.
  • Back-up Battery: A 12V battery is available for operation during power outages, excluding heater activation.

Additional Features
  • Emergency Shut-Down: Press the power button to interrupt all functions.
  • Lock-Out Feature: Prevent unauthorized access by holding the power button for 5 seconds.
See more

Catalog excerpts

MAX SINGLE CANTILEVER-1

MAX SINGLE CANTILEVER LIGHT, HEATERS AND AUTOMATION Note: Certain models may include a temporary shipping bracket that needs to be removed. Remove Heater Brackets Step 1 Remove all packaging from in and around umbrella and lay flat on the floor. To prevent damage to the umbrella, lay a soft cloth or large piece of cardboard on the floor. Remove hex screw from elbow fitting. Remove flat-head hex screw from heater arm and bracket. Discard bracket and save screw for next step. flat-head screw elbow fitting Mount heater arm to elbow fitting with flat-head screw from previous step. Note: Add a drop of provided Loctite to the end of the screw threads. flat-head screw add Loctite 1007308 1 | tuuci Repeat steps 1 through 4 for all heater arms.

 Open the catalog to page 1
MAX SINGLE CANTILEVER-2

LIGHT, HEATERS AND AUTOMATION Step 6 Pull pin from cam lock and lift the handle to unlock umbrella. Once you have leveled the stem using the base installation instructions, slide the beauty cover and umbrella over the security stem (security stem is included with umbrella). Note: Ensure that cables are not pinched when inserting the umbrella over the security stem and when installing the beauty cover. beauty cover security stem Lock umbrella down by pushing the cam lock handles in the down position and lock with pin. Mount beauty cover over control box. control box beauty cover cam lock handle...

 Open the catalog to page 2
MAX SINGLE CANTILEVER-3

LIGHTS, HEATERS AND AUTOMATION Step 9 Plug in power cord of your Automated Umbrella into 220V receptacles. The TUUCI logo on control panel will be backlit in white when the umbrella is properly plugged into the power source. Press the Power button to turn on the umbrella. The button will be backlit in red when the power is ON. In addition, when the umbrella is ON, the open umbrella icon, closed umbrella icon, light icon and heater icon will all be backlit in white. Press the close umbrella button to move the umbrella down to align with the eye of the cable connector. Press the close umbrella...

 Open the catalog to page 3
MAX SINGLE CANTILEVER-4

LIGHT, HEATERS AND AUTOMATION OPENING UMBRELLA Opening umbrella Press the open umbrella icon button to open the umbrella. The color will change from white to blue after pressing the button and during the opening of the umbrella. When it is fully opened, the button color will change to white. The umbrella must be fully opened for 5 seconds before the Ambia LED light can be turned on. Turning the Ambia LED light on Press the lightbulb icon button to turn on the Ambia LED light. The color will change from white to blue after pressing the button, signaling that the light is ON. Turning the heaters...

 Open the catalog to page 4
MAX SINGLE CANTILEVER-5

LIGHT, HEATERS AND AUTOMATION - Features and Functions Emergency shut-down or interrupt feature on the Automated Umbrella control panel Press the Power button to shut-down or interrupt the operation of any function (Ambia LED light, heaters, open and close). The red light on the Power button will turn OFF. The white lights on the heater icon, the light icon and open and close icon buttons will turn OFF. Press the Power button to turn the umbrella back ON. Control panel indicator when the Automated Umbrella is not level (tipped or tilted on an angle) The Power button will be flashing in yellow...