1. Catalogs
  2. Turbo Air
  3. CRT-77-1R CRT-77-2R

CRT-77-1R CRT-77-2R

CRT-77-1R CRT-77-2R
1 / 12 PagesView full catalog

CRT-77-1R CRT-77-2R

Product catalog summary
Specifications:
The document details two models, CRT-77-1R and CRT-77-2R, differing in the number of glass doors. Both models operate on 115V/60Hz with R-134A refrigerant and consume 6.5 amps. The CRT-77-1R weighs 89 lbs, and the CRT-77-2R weighs 90 lbs.
General Information:
These refrigerated display cases feature a four-sided glass cabinet for optimal visibility, LED lighting, and a compact design for narrow spaces. They are intended for indoor use only.
Handling and Installation:
The refrigerator should be handled carefully, avoiding tilting over 45 degrees. It should be placed in a dry, well-ventilated area, away from heat sources and direct sunlight, with a minimum clearance of 10 cm from the wall.
Power Supply:
The unit requires a dedicated 110/60Hz single-phase AC power supply and should not share a socket with other appliances to prevent overheating and fire hazards.
Usage and Caution:
The refrigerator should be plugged into a 115V exclusive socket. Temperature control is adjustable, and rack height can be modified. Avoid blocking air circulation and ensure food is at room temperature before refrigeration.
Maintenance:
Regular cleaning is necessary. The exterior should be cleaned with a neutral detergent, and interior racks can be washed with water. Unplug the refrigerator before maintenance.
Troubleshooting:
Common issues include no refrigeration, unsatisfactory cooling, and excessive noise. Solutions involve checking power connections, ensuring proper ventilation, and verifying door seals.
Refrigeration System Principle:
The system operates on a cycle of compression, condensation, throttling, and vaporization, using components like the compressor, condenser, capillary, and evaporator.
Warranty:
Turbo Air offers a one-year warranty on the cabinet and parts, with an additional four-year warranty on the compressor. The warranty is void if the system is altered or improperly maintained. Claims require proof of purchase and installation details.
Warranty Coverage Overview:
Turbo Air provides a one-year parts and labor warranty for new refrigerated components, valid for one year from installation or 15 months from shipment. A four-year extended warranty covers hermetically sealed compressors for up to five years and three months from shipment.
Warranty Claims Process:
Claims must be submitted to Turbo Air with model number, serial number, proof of purchase, installation date, and defect information. Compressor replacements require returning the compressor or its tag.
Exclusions and Limitations:
The warranty does not cover consequential damages, economic losses, or damages from food spoilage. It is non-transferable and void if the product is altered, neglected, misused, or damaged by external factors. It does not apply outside the U.S. and Canada.
Specific Requirements for 404A/134a Compressors:
For the five-year compressor warranty, use R404A or R134a refrigerant with polyol ester lubricant, replace the drier when servicing, achieve a vacuum of 500 microns or lower, and replace the suction drier and 620 drier if the compressor is grounded. Compressors must be obtained through Turbo Air unless specified otherwise.
See more

Catalog excerpts

CRT-77-1R CRT-77-2R-1

Turbo Air Speeds up the Pace of Innovation Display Cases Diamond Show Cases Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! REFRIGERATED CASES

 Open the catalog to page 1
CRT-77-1R CRT-77-2R-2

HANDLE WITH CARE 4 PREPARATION AND POWER SUPPLY 5 PRINCIPLE OF REFRIGERATION SYSTEM 8 ELECTRIC CIRCUIT DIAGRAM 8 SERIAL NUMBER The serial number is located on the data label inside. Please retain the unit's serial number for service purpose.

 Open the catalog to page 2
CRT-77-1R CRT-77-2R-3

GENERAL 1. Beautiful 4 sided glass cabinet allows visibility from all sides to optimize display effect. 2. Safety shielded 4 LED lighting system on every corner of the cabinet ensures a longer life and brighter lighting than fluorescent light bulbs, providing attractive, enhanced and shadow-free illumination. 3. Compact size and counter top design occupies minimum space but maximize impulse sales. 4. It’s great space efficiency is ideal for narrow space restaurants and convenience store 5. Elegant contemporary Euro design will enhance the interior and space decoration of any store. STRUCTURE...

 Open the catalog to page 3
CRT-77-1R CRT-77-2R-4

HANDLE WITH CARE Handle with care Unplug the wall socket first. Never tilt it over 45 degree during handling. Always locate the refrigerator at a dry place. Sufficient space Well environment Keep the rear unit no less than 10cm(4inch) from wall or other substance which will stop the air flow. Always locate the refrigerator at a place with Ambient Temperature 16-32ºC / 60.8-89.6ºF. The refrigerator might doesn’t work properly if higher or lower this temperature range. For the first time use, wait for 2 hours after handling and then plug the wall socket and start it. Far from heat source Never...

 Open the catalog to page 4
CRT-77-1R CRT-77-2R-5

PREPARATION & POWER SUPPLY Exclusive power socket Normally, the power supply should be 110/60Hz single phase AC with exclusive single phase three pin receptacle. (125V, 10-15A) Never let the refrigerator share the common socket with other appliance, otherwise the cable becomes hot and fire might be resulted. Protect cables Never break or damage the cables otherwise current leakage and fire might be resulted. Never giver the refrigerator surface a flush otherwise current leakage might be resulted. Prevent from flammables and explosive Never put any flammable or explosive inside the refrigerator...

 Open the catalog to page 5
CRT-77-1R CRT-77-2R-6

USE & CAUTION 1. How to start Plug the refrigerator on 115V exclusive socket. After the refrigerator running, put hand on the air suction to confirm it is sufficient cold. Then put th the cold box. 2. Regulate temperature Normally put the controller at “MID” step. The evaporator might be frosted if the controller is at the “FREEZE” step and the refrigerator capability might be decreased. The range of the controller is shoen, which is divided into step of “ LOW, MID, HIGH AND FREEZE”. The temperature inside the refrigerator would go down if you turn the knob clockwise, while the temperature would...

 Open the catalog to page 6
CRT-77-1R CRT-77-2R-7

MAINTENANCE 1. Notice Often keep the refrigerator clean and periodical maintenance is necessary. Always unplug the socket before maintenance. Never use damaged plug or loose socket to prevent electric shock or short circuit. Never flush the refrigerator. Never use alkali detergent, soap, gasoline, acetone or brush. 2. Clean exterior Dip soft cloth in neutral detergent (Tableware detergent) to clean the exteria of refrigerator, then wipe it with dry soft cloth. 3. Clean interior Take rack out for cleaning with water. Use soft cloth to wipe the box. 4. Shut down refrigerator for a long time Take...

 Open the catalog to page 7
CRT-77-1R CRT-77-2R-8

PRINCIPLE OF REFRIGERATION SYSTEM The principle of compression refrigeration consists of “Compression”, “Condensation”, “Throttling” and “Vaporization”. The compression is undertaken by compressor, the condensation is completed by condenser, the throttling valve is executed by capillary and the vaporization is implemented by evaporator. When the coolant is circulating in the closed refrigeration system, the compressor sucks coolant, which has absorbs heat in evaporator, the coolant becomes a high pressure and high temperature gas. In consider, it dissipates heat in air, while the coolant is reliquaries...

 Open the catalog to page 8
CRT-77-1R CRT-77-2R-9

MAJOR PARAMETERS Model Parameter Coolant and injecti on quanti ty Rated Input Power (W): Type of cl i mate Ref ri gerati on temperature El ectri cshock protecti on cl ass Power consumpti on(K W.H/24H) Hi gh-si de design pressures L ow-si de design pressures Total eff ective volume Net weight Rated Vol tage(V ) Rated Frequency(Hz) Overal l di mensi on Package dimension(mm) NOTE 1. The electric circuit diagram and parameters on the product nameplate are final ones if they have been changed. 2. The design might be improved without notice. This appliance is not intended for use by person (including...

 Open the catalog to page 9
CRT-77-1R CRT-77-2R-10

MANUFACTURING COMPANY ONE YEAR WARRANTY Turbo Air warrants to the original purchaser of every new Turbo Air refrigerated unit, the cabinet and all parts thereof, to befree from defects in material or workmanship, under normal use and service, for a period of one (1) year from the date of original installation or 15 months after shipment date from Turbo Air , whichever occurs first. Any parts covered by this warranty that are examined and determined by Turbo Air to have been defective within one (1) year of original installation or fifteen (15) months after shipment date from manufacturer, whichever...

 Open the catalog to page 10
CRT-77-1R CRT-77-2R-11

What is NOT covered by this warranty Turbo Airʼs sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations below. This warranty neither assumes nor authorizes any person to assume obligations other than expressly covered b y this warranty. 1. WARRANTY IS NOT TRANSFERABLE. This warranty is not assignable and applies only in favor of the original purchaser/user to whom delivered. ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANTIES HEREIN MADE AND SHALL VOID ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY...

 Open the catalog to page 11

All Turbo Air catalogs and technical brochures

  1. TPR-93SD-D6-N

    2  Pages

  2. TPR-67SD-D2-N

    2  Pages

  3. PRO-77F-N

    2  Pages

  4. PUR-48-D4-N

    2  Pages

  5. MUR-20SG-N6

    2  Pages

  6. MUR-34S-N6

    2  Pages

  7. TST-28SD-D2-N

    2  Pages

  8. CATALOG 2018

    218  Pages

  9. TWF-28SD-N

    2  Pages

  10. TMKC-34S

    2  Pages

  11. TMKC-49S

    2  Pages

  12. TMKC-58S

    2  Pages

  13. TMKC-34D

    2  Pages

  14. TMKC-49D

    2  Pages

  15. TMKC-58D

    2  Pages

  16. TGM-35SD

    2  Pages

  17. TGM-15SD

    2  Pages

  18. JUR-60-G

    2  Pages

  19. JBT-36

    2  Pages

  20. JST-48

    2  Pages

  21. MST-28

    2  Pages

  22. TST-72SD

    2  Pages

  23. TPR-67SD-D2

    2  Pages

  24. TPR-44SD

    2  Pages

  25. JRF-45

    2  Pages

  26. M3F24-2

    2  Pages

  27. M3R72-6

    2  Pages

  28. PRO-77-6R

    2  Pages

  29. PRO-26R

    2  Pages

  30. MSR-23G-1

    2  Pages

  31. MSF-49NM

    2  Pages

  32. MSR-23NM

    2  Pages

  33. TSF-35SD

    2  Pages

  34. TSR-23SD*

    2  Pages

  35. JRF-19

    2  Pages

  36. SAKURA-50

    2  Pages

  37. TPR-67SD-D4

    2  Pages

  38. TSR-35SD

    2  Pages

  39. JBT-60

    2  Pages

  40. TWR-48SD-D2

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.