Louvres
1 /32Pages

Louvres

Louvres
1 /32Pages

Catalog excerpts

Louvres-1

Louvres Tunal comfort solutions for better living.

 Open the catalog to page 1
Louvres-2

life is better with facade systems

 Open the catalog to page 2
Louvres-3

3 Tunal louvres. 3 MR20-V MR20V-FL . 4 MR20V-GL20, 24, 28 . 6 MR20V-SM. 8 MR34-V MR34V-FL . 10 MR34V-GL24. 12 MR34-Z MR34Z-FL . 14 MR34Z-GL20, 24, 28 . 16 MR34Z-SM. 18 MR50-Z MR50Z-FL . 20 MR50Z-GL24. 22 MR65-Z MR65Z-FL . 24 MR75-Z MR75Z-FL . 26 Turrets. 28 Standard sizes. 30 Self-assembly. 31 Louvres Simple self-assembly. The basic requirement for a louvre is to move air in and around a building, thereby creating added comfort and convenience for better living. Tunal louvres come in various blade types and numerous frame choices that allow their use as an integral part of a window system or...

 Open the catalog to page 3
Louvres-4

CMY MR20FL DOORSNEDE - NED.pdf 11-02-2008 14:24:01 Options - A specific water drainage profile has been developed to improve the watertightness of the louvre. This profile is fitted under the lowest blade.Tests performed by BSRIA demonstrate the effectiveness of this extra profile. - Controllable (hit and miss vents) All louvre panels are permanent as standard. These panels can be made controllable by fitting hit and miss ventilators to the back of the panel.The hit and miss ventilators come in the same finish as the panel. Standard control: knob. Cord control possible. - Bracket Louvre chevron...

 Open the catalog to page 4
Louvres-5

C M Y CM MY CY CMY K MR20FL MONTAGEPLAN - NED.pdf 11-02-2008 14:23:53 P001 Flanged frame profile MR34 P007 Reinforcement profile P012 Water drainage profile P015 V-blade P069 Use of gasket T020 T-piece P007 T051 Corner cleat MR34 T058/12 Multiple MR20 blade support 12mm T058/25 /P007 Multiple MR20 blade support 12mm P007

 Open the catalog to page 5
Louvres-6

C M Y CM MY CY CMY K MR20GL20 DOORSNEDE - NED.pdf 14-01-2008 10:16:32 Options - A specific water drainage profile has been developed to improve the watertightness of the louvre. This profile is fitted under the lowest blade.Tests performed by BSRIA demonstrate the effectiveness of this extra profile. - Controllable (hit and miss vents) All louvre panels are permanent as standard. These panels can be made controllable by fitting hit and miss ventilators to the back of the panel.The hit and miss ventilators come in the same finish as the panel. Standard control: knob. C ord control possible. Louvre...

 Open the catalog to page 6
Louvres-7

P069 Use of gasket T020 T-piece P007 T051 Corner cleat MR34 T058/12 Multiple MR20 blade support 12mm T058/25 /P007 Multiple MR20 blade support 12mm P007 P004 Glaze in frame profile 28 mm P005 Glaze in frame profile 24 mm P006 Glaze in frame profile 20 mm P007 Reinforcement profile P012 Water drainage profile P015 V-blade

 Open the catalog to page 7
Louvres-8

C M Y CM MY CY CMY K MR20SM DOORSNEDE - NED.pdf 10-01-2008 19:40:09 Options - A specific water drainage profile has been developed to improve the watertightness of the louvre. This profile is fitted under the lowest blade.Tests performed by BSRIA demonstrate the effectiveness of this extra profile. - Controllable (hit and miss vents) All louvre panels are permanent as standard. These panels can be made controllable by fitting hit and miss ventilators to the back of the panel.The hit and miss ventilators come in the same finish as the panel. Standard control: knob. C ord control possible. Louvre...

 Open the catalog to page 8
Louvres-9

T020 T-piece P007 T051 Corner cleat MR34 T058/12 Multiple MR20 blade support 12mm T058/25 /P007 Multiple MR20 blade support 12mm P007 P007 Reinforcement profile P012 Water drainage profile P014 Surface mounted frame profile P015 V-blade P069 Use of gasket

 Open the catalog to page 9
Louvres-10

10 58 52.2 40 34 20.3 38.5 33.8 H 34 20.3 38.5 24 56 20 7.3 22 H 13-01-2008 16:37:59 Options - A specific water drainage profile has been developed to improve the watertightness of the louvre. This profile is fitted under the lowest blade.Tests performed by BSRIA demonstrate the effectiveness of this extra profile. - Controllable (hit and miss vents) All louvre panels are permanent as standard. These panels can be made controllable by fitting hit and miss ventilators to the back of the panel.The hit and miss ventilators come in the same finish as the panel. Standard control: knob. Cord control...

 Open the catalog to page 10
Louvres-11

P069 Use of gasket T049/12 Multiple MR34V blade support 12 mm T051 Corner cleat MR34 P007 Reinforcement profile P048 V-blade P070 Frame profile

 Open the catalog to page 11
Louvres-12

12 34 20.3 38.5 24 56 20 7.3 22 H Options - A specific water drainage profile has been developed to improve the watertightness of the louvre. This profile is fitted under the lowest blade.Tests performed by BSRIA demonstrate the effectiveness of this extra profile. - Controllable (hit and miss vents) All louvre panels are permanent as standard. These panels can be made controllable by fitting hit and miss ventilators to the back of the panel.The hit and miss ventilators come in the same finish as the panel. Standard control: knob. C ord control possible. Louvre V-blades 34 mm Glazed-in louvre...

 Open the catalog to page 12
Louvres-13

P069 Use of gasket T049/12 Multiple MR34V blade support 12 mm T051 Corner cleat MR34 P007 Reinforcement profile P048 V-blade P071 Frame profile

 Open the catalog to page 13
Louvres-14

14 MR34FL DOORSNEDE - NED.pdf 10-01-2008 19:36:06 C M Y CM MY CY CMY K MR34 ONDERBIJPASSING - NED.pdf 10-01-2008 21:00:07 Options - A specific water drainage profile has been developed to improve the watertightness of the louvre. This profile is fitted under the lowest blade.Tests performed by BSRIA demonstrate the effectiveness of this extra profile. - Controllable (hit and miss vents) All louvre panels are permanent as standard. These panels can be made controllable by fitting hit and miss ventilators to the back of the panel.The hit and miss ventilators come in the same finish as the panel....

 Open the catalog to page 14
Louvres-15

P069 Use of gasket T020 T-piece P007 T051 Corner cleat MR34 T054/12 Multiple MR34 blade support 12mm T054/25 /P007 Multiple MR34 blade support 12mm P007 P001 Flanged frame profile MR34 P003 Upper blade MR34 P007 Reinforcement profile P009 Short blade MR34 P012 Water drainage profile P013 Blade with screw hole

 Open the catalog to page 15
Louvres-16

16 MR34GL20 DOORSNEDE - NED.pdf 14-01-2008 10:19:09 P009 P008 P013 P013 P013 P013 P009 P009 P009 0 13 14 22 22 34 34 34 12 12 Options - A specific water drainage profile has been developed to improve the watertightness of the louvre. This profile is fitted under the lowest blade.Tests performed by BSRIA demonstrate the effectiveness of this extra profile. - Controllable (hit and miss vents) All louvre panels are permanent as standard. These panels can be made controllable by fitting hit and miss ventilators to the back of the panel.The hit and miss ventilators come in the same finish as the panel....

 Open the catalog to page 16

Archived catalogs

  1. Tunal Catalogue

    16  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.