VFR
8Pages

{{requestButtons}}

Catalog excerpts

VFR - 1

for the adjustment of volume flow rates

Open the catalog to page 1
VFR - 2

Contents · Description Description __________________________________ Type VFR – The System ________________________ Construction · Dimensions ______________________ Leakage flow rate ____________________________ VFR with hand wheel TROX type VFR dampers are used to adjust volume flow rates in air-conditioning and ventilation systems. They can be used in circular ventilation ducts with nominal sizes 80 to 250 and system pressures up to 1000 Pa. The damper blade is designed without a seal and with a circumferential gap between the case and blade tip of approximately 3 mm. For the flow rate...

Open the catalog to page 2
VFR - 3

Type VFR – The System There are 3 configurations of the type VFR damper: • Manual operation • Actuator with potentiometers (E01, E02) • Actuator with mechanical stops (M01, M02) On each VFR, a diagram label is shown in order to determine the settings on site (example nominal size 125). Adjustment scale Diagram label Actuator with potentiometers (E01, E02) Actuator with mechanical stops (M01, M02) Hand wheel

Open the catalog to page 3
VFR - 4

Construction · Dimensions Characteristics – – – – – – – For adjustment of flow rates and pressures Circular construction in 10 nominal sizes Manual adjustment Stepless adjustment of the damper blade from 0 to 10 Maximum system pressure 1000 Pa Damper blade mechanism maintenance-free Operating temperature: 10 to 50 °C Construction features Mechanical stops Keep clear to provide access for operation Adjustment with potentiometers Keep clear to provide access to actuator Adjustment with hand wheel 15 – Spigot connection with lip seal for circular connecting ducts according to EN 1506 or EN...

Open the catalog to page 4
VFR - 5

Construction · Dimensions · Leakage flow rate Materials – Casing in galvanised sheet steel – Hand wheel, damper blade and bearings made of plastic flame retardant (V0) according to UL 94 Closed blade (0) leakage flow rate Adjustment with mechanical stops 232 Keep clear to provide access to actuator

Open the catalog to page 5
VFR - 6

Nomenclature · Quick selection Nomenclature LPA in dB(A) : A-weighted sound pressure level of air-regenerated noise, including a 5 dB system attenuation in l/s or m³/h : Flow rate in Pa : Total differential pressure All sound pressure levels are based on 20 µPa. All noise levels determined in a reverberation chamber. Flow rate Sound pressure level LpA in dB(A)

Open the catalog to page 6
VFR - 7

Min/max changeover Actuator with potentiometers Actuator 24 V (E01) Supply voltage: Service button Potentiometer Indicator light Actuator with mechanical stops Power rating: Control signal: Protection level: Actuator 230 V AC (E02) Supply voltage: 230 V AC ± 20 %, 50/60 Hz Power rating: 3 VA Control signal: 1- or 2-wire control Protection level: IP 42 Functional testing – Press service button – Actuator turns towards MIN – Actuator turns towards MAX – Actuator returns to control mode Indicator light provides functional information – Permanently on: Position set – Blinking once a second:...

Open the catalog to page 7
VFR - 8

Order Details Specification text Circular damper in 10 nominal sizes for the adjustment of flow rates in air-conditioning and ventilation systems, can be used with system pressures up to 1000 Pa. Consists of the casing with damper blade and the hand wheel for stepless adjustment. Spigot connection with lip seal for circular connecting ducts according to EN 1506 or EN 13180. Casing air leakage complies with EN 1751, class B. Casing in galvanised sheet steel. Hand wheel, damper blade and bearings made of plastic flame retardant (V0) according to UL 94. Order code / asing Galvanised steel, no...

Open the catalog to page 8

All TROX catalogs and technical brochures

  1. X-GRILLE Cover

    18 Pages

  2. ATVC-100

    8 Pages

  3. X-CUBE Compact

    12 Pages

  4. ARR

    2 Pages

  5. VMRK

    4 Pages

  6. Tunnel dampers

    20 Pages

  7. FKS-EU

    20 Pages

  8. CAK

    6 Pages

  9. Type NL

    8 Pages

  10. Type PKV

    7 Pages

  11. Type BID

    8 Pages

  12. Type QLI

    8 Pages

  13. LVC

    9 Pages

  14. RM-O-3-D

    7 Pages

  15. RM-O-VS-D

    7 Pages

  16. FK-EU

    56 Pages

  17. EK-01

    14 Pages

  18. XSA

    12 Pages

  19. MSA

    12 Pages

  20. SCHOOLAIR-V

    12 Pages

  21. SCHOOLAIR-B

    12 Pages

  22. FSL-B-SEK

    4 Pages

  23. DID632

    20 Pages

  24. DID300B

    12 Pages

  25. DID312

    16 Pages

  26. AGW

    24 Pages

  27. AGS

    24 Pages

  28. DLQ-1...4-AK

    13 Pages

  29. DQ/ADQ

    9 Pages

  30. DLQ/ADLQ

    10 Pages

  31. DLK-Fb

    4 Pages

  32. VD

    10 Pages

  33. QSH · ISH

    8 Pages

  34. DLQL

    12 Pages

  35. X-CUBE

    16 Pages

  36. FV-K90

    12 Pages

  37. AK-Ex

    5 Pages

  38. JZ-RS

    5 Pages

  39. FKRS-EU

    28 Pages

  40. Star Climate

    16 Pages

  41. SD

    10 Pages

  42. AIRNAMIC

    12 Pages

  43. XARTO

    12 Pages

  44. X-CUBE COMPACT

    10 Pages

Archived catalogs

  1. Slot Diffuser

    11 Pages