Catalog excerpts

Type FSL-B-ZAB-1

Ein UnternehmenCompanyGruppe A TROX GROUP der Trox FassadenSystemLüftung GmbH & Co KG Heinrich-Trox-Platz D-47506 Neukirchen-Vluyn Telephone +49 / 28 45/ 202-711 Telefax +49 / 28 45/ 202-225 e-mail: [email protected] www.fsl-gmbh.com Project information – Laimer Projektinformation IBCWürfel – Decentralised sill ventilation units FSL-B-ZAB Dezentrale Brüstungslüftungsgeräte in Zargenbauform PI/FSL/3/D/1 PI/FSL/12/EN/2 Laimer Würfel · Munich, Germany Property developers: HOCHTIEF Projektentwicklung Architects: “frick krüger nusser plan 2” Utilities consultants: Planungsbüro – J. Weißenhorn CAE – H. König The building The Laimer Würfel building on the city centre site in Landsberger Strasse in the Laim district of Munich, Germany is a contemporary office building characterised by the highly efficient use of surfaces and great individuality. Each of the 11 upper floors in the complex has approximately 1,900 m2 of office space. The multi-functional ground floor includes retail areas, a conference area and a casino. Two impressive entrance areas lead into the Laimer Würfel building. Supply and extract air unit, type FSL-B-ZAB left-handed construction The striking element of the facade – copper – is contrasted and complemented by preweathered zinc elements. The multi-facetted appearance of the facade is finished off by high quality solar control glass on the ground floor and expanded metal solar shading in front of the office windows. The upper storeys are individually and mechanically ventilated by type FSL-B-ZAB decentralised ventilation units built into the sill of the facade. The use of these modular units with interchangeable function boxes is the best way to accommodate the flexibility of office use. This design of unit provides heating and cooling of the office spaces, in addition to mechanical ventilation with heat recovery and air filtration. Some facade modules do not have these decentralised ventilation units but are equipped with recirculated air heating and cooling units of the same dimensions (type FSL-B-UML). The system is further complemented by opening windows and additional cooling capacity by means of chilled ceilings may also be provided to deal with higher thermal loads. The ground floor, kitchens and store rooms are ventilated by a central plant air conditioning system. Facade with integral sill ventilation unit Design changes reserved · All rigths reserved © TROX GmbH (2/2007) The Ventilation and Air Conditioning concepts

 Open the catalog to page 1
Type FSL-B-ZAB-2

A TROX GROUP Company Project information – Laimer Würfel – Decentralised sill ventilation units FSL-B-ZAB PI/FSL/12/EN/2 Ventilation schematic type FSL-B-ZAB 11 Static heating operation Outside F7 F7 – Outside air filter G3 – Extract air filter Recuperative heat recovery unit Supply air fan Exhaust air fan Volume flow rate controller Coil unit Motorised thermal changeover damper Motorised heat recovery unit bypass damper Backdraught damper Motorised shut-off damper Silencer Base module casing Function box Coil unit Supply and extract air unit, right-handed construction ቨ Thermal changeover unit...

 Open the catalog to page 2
Type FSL-B-ZAB-3

A TROX GROUP Company Project information – Laimer Würfel – Decentralised sill ventilation units FSL-B-ZAB PI/FSL/12/EN/2 Function of the supply air and extract air unit (FSL-B-ZAB) The outside air is taken in through the weather-resistant louvres. The mechanical automatic flow rate controller ቧ at the unit entry limits the outside air volume flow to a set maximum. This also prevents excessive external air flow which could occur due to high wind pressure on the facade thus causing draughts in the conditioned space. The backdraught damper prevents conditioned air being sucked out of the room against...

 Open the catalog to page 3
Type FSL-B-ZAB-4

A TROX GROUP Company Project information – Laimer Würfel – Decentralised sill ventilation units FSL-B-ZAB PI/FSL/12/EN/2 Dimensions 491 Chilled water return Chilled water flow Hot water return Hot water flow Technical Data The acoustic, aerodynamic and thermal optimisation of the under sill units are based on the project specific requirements. The coil selection was based on the required thermal performance and volume flows. The performance of the unit is summarised below. Supply and extract air unit Volume flow Sound power level Sound pressure level with an 8 dB room attenuation Standard sound...

 Open the catalog to page 4

All TROX catalogs and technical brochures

  1. Retrofit kits

    6  Pages

  2. X-GRILLE Cover

    18  Pages

  3. ATVC-100

    8  Pages

  4. X-CUBE Compact

    12  Pages

  5. ARR

    2  Pages

  6. VMRK

    4  Pages

  7. VFR

    8  Pages

  8. Tunnel dampers

    20  Pages

  9. FKS-EU

    20  Pages

  10. CAK

    6  Pages

  11. Type ST · XT

    8  Pages

  12. Type NL

    8  Pages

  13. Type PKV

    7  Pages

  14. Type BID

    8  Pages

  15. Type QLI

    8  Pages

  16. LVC

    9  Pages

  17. RM-O-3-D

    7  Pages

  18. RM-O-VS-D

    7  Pages

  19. FK-EU

    56  Pages

  20. EK-01

    14  Pages

  21. XSA

    12  Pages

  22. MSA

    12  Pages

  23. SCHOOLAIR-V

    12  Pages

  24. SCHOOLAIR-B

    12  Pages

  25. FSL-B-SEK

    4  Pages

  26. DID632

    20  Pages

  27. DID300B

    12  Pages

  28. DID312

    16  Pages

  29. AGW

    24  Pages

  30. AGS

    24  Pages

  31. DLQ-1...4-AK

    13  Pages

  32. DQ/ADQ

    9  Pages

  33. DLQ/ADLQ

    10  Pages

  34. DLK-Fb

    4  Pages

  35. VD

    10  Pages

  36. QSH · ISH

    8  Pages

  37. DLQL

    12  Pages

  38. X-CUBE

    16  Pages

  39. FV-K90

    12  Pages

  40. AK-Ex

    5  Pages

  41. JZ-RS

    5  Pages

  42. FKRS-EU

    28  Pages

  43. Star Climate

    16  Pages

  44. SD

    10  Pages

  45. AIRNAMIC

    12  Pages

  46. XARTO

    12  Pages

  47. X-CUBE COMPACT

    10  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.