TVJ-Easy/TVT-Easy

Product catalog summary
Innovation
The TROX TVJ-/TVT-Easy controllers provide an innovative air handling solution with features like easy selection based on duct dimensions, tool-free flow rate adjustment, functional testing via a service button, and an indicator light for functional checks. This technology is developed in collaboration with consultants and customers to save time during setup.
Construction and Dimensions
The controllers feature electronic flow rate control with a green indicator light for status information. Functional testing is done by pressing a service button to cycle the damper blade. Designed for high control accuracy, they include a transparent protection cover and clamping bracket for wiring, suitable for non-aggressive air, and comply with standards such as EN 1751 and DIN 1946. They are maintenance-free.
Technical Data and Nomenclature
Detailed technical data includes supply voltage, power rating, control signal specifications, and safety requirements. The controllers operate within a differential pressure range of 20 to 1000 Pa and are suitable for operating temperatures between 10 to 50 °C.
Selection of Dimensions
Dimensions are selected based on flow rate ranges and duct dimensions. Tables are provided for selecting dimensions and flow rates, ensuring accurate adjustment using a flow rate scale attached to each controller.
Acoustic Quick Selection
Acoustic data is provided for different flow rates and pressure differentials, with tables indicating sound pressure levels for various configurations. Corrections for duct and room attenuation are included.
Flow Rate Adjustment
Flow rates are adjustable by the customer, with settings for minimum and maximum flow rates. The controllers can operate in variable or constant flow rate modes, with factory settings provided for initial setup.
Characteristics and Wiring Examples
Wiring diagrams are provided for connecting the controllers to supply voltage and external room temperature controllers. Override controls for damper blade positions are detailed, emphasizing compliance with local electrical standards.
Order Details
The specification text outlines product details for ordering, including the make, type, and features of the controllers, emphasizing their suitability for variable air volume flow systems.
Specifications
  • Controllers can be adjusted without supply voltage during installation.
  • Transparent protection cover prevents accidental resetting.
  • Control damper blade is delivered in a 45° position for ventilation.
  • Flow rate adjustment is tool-free, with functional testing via a service button and indicator light.
  • Electrical connections use screw terminals, with a voltage range of 0 to 10 VDC.
  • Override controls possible with external switches.
Special Characteristics
  • High visibility external indicator light for function signaling.
  • Factory functional testing of each unit.
  • Integral differential pressure sensor resistant to contamination.
  • Compliance with EN 1751 and DIN 1946 standards for air leakage and pressure range.
Materials
  • Casing made of galvanized sheet steel, with aluminum sensor tubes and blades.
  • Gear wheels made of antistatic plastic, heat resistant up to 50°C.
Acoustic Cladding
  • Optional acoustic cladding reduces noise by at least 6 dB.
  • Consists of 40 mm mineral wool with a galvanized steel outer cover.
Optional Features
  • TX secondary silencer reduces air regenerated noise by approximately 9 dB at 250 Hz.
  • Mineral wool lining conforms to fire rating class A2 and is bio-degradable.
Order Examples
  • TVJ-Easy and TVT-Easy models with specific dimensions.
  • TX secondary silencer with specified dimensions.
See more

Catalog excerpts

TVJ-Easy/TVT-Easy-1

Type TVJ-Easy • TVT-Easy

 Open the catalog to page 1
TVJ-Easy/TVT-Easy-2

Contents Innovation Construction · Dimensions Dimensions Technical data · Nomenclature Selection of dimensions Select dimensions Acoustic quick selection Flow rate adjustment Characteristics · Wiring examples Order details Green light: Ready!

 Open the catalog to page 2
TVJ-Easy/TVT-Easy-3

Innovation TROX TVJ-/TVT-Easy – the innovative solution ½ Easy ½ Easy Selection according to duct dimensions Functional testing with service button Flow rate adjustment without adjustment tool Functional check by indicator light The proven technology of the compact flow rate controller has been optimized. Valuable on site time saved by simple set up. TVJ-/TVT-Easy, developed with consultants and customers! ᕡ Differential pressure grid · Control damper blade ᕣ Flow rate scale ᕤ TROX Compact-controller ᕥ Connection terminals ᕦ Service button position indicator ᕩ Potentiometers ‡min µ Indicator...

 Open the catalog to page 3
TVJ-Easy/TVT-Easy-4

Construction · Dimensions – For delivery, control damper blade in 45° position – Flange both ends, suitable for fitting system 30 connecting profiles – Casing air leakage flow rate complies with DIN EN 1751, class A – The mechanical components are maintenance-free – Operating temperature range 10 to 50 °C – Storage temperature range –20 to +80 °C Characteristics – Electronic flow rate control – Green indicator light provides functional information: permantently on = set blinking = not set off = no supply voltage – Functional testing as follows: Press service button for at least 1 second Actuator...

 Open the catalog to page 4
TVJ-Easy/TVT-Easy-6

Technical Data · Nomenclature TROX Compact-controller technical data Supply voltage: Power rating: Control signal: Flow rate actual value signal: Transducer range: Running time: Torque: Safety class: Protection level: 24 VAC ± 20 %, 50/60 Hz or 24 VDC ± 10 % max. 5 VA (for a.c. voltage) max. 3 W (for d.c. voltage) 0 to 10 VDC, Ri > 100 kΩ 0 to 10 VDC linear, max. 0.5 mA 2 to 300 Pa 120 to 300 sec. for 87° 15 Nm III (Save voltage) min. IP 20 Additional safety requirements for the TROX Compact-controller – Installation and assembly must be performed by qualified personnel. Assembly must be carried...

 Open the catalog to page 6
TVJ-Easy/TVT-Easy-7

Selection of Dimensions The selection of the dimensions takes place according to the flow rate range specified by the consultant. Minimum total pressure differentials and flow rate tolerance The accurate adjustment of the flow rate setpoints is carried out using a flow rate scale, which is attached on each controller. For the acoustic characteristics in tables on page 8, duct air velocity is needed. This can be determined from the following table. 1) Additional factor to be taken into account Flow rate ranges . Vmin unit2) Dimensions H = 600, 800 and 1000 only available as TVJ-/TVJD-Easy! 600...

 Open the catalog to page 7
TVJ-Easy/TVT-Easy-8

Acoustic Quick Selection 1) 4 dB/octave ceiling reduction and 5 dB/octave room attenuation have been allowed for in the calculation of case-radiated noise. Acoustic data for differential pressure up to 1000 Pa, see on-line design programme "Air terminal units". Please refer to leaflet no. 5/4/EN/.. for acoustic performance data and selection example.

 Open the catalog to page 8
TVJ-Easy/TVT-Easy-9

Flow Rate Adjustment On each 7VJ-/TVT-Easy, a flow rate scale is available in order to determine the settings on site (see example size 500 x 200). Variable flow rate control The required flow rates must be adjusted by the customer. If \/min is set higher than \/max, then \/min is provided as a constant flow rate, even if a control signal is transmitted. If \/min is set on 0 %, then control is between shut-off and \/max. If the control signal falls below 0.1 VDC, the control damper closes. Constant flow rate control The constant flow rate can be set with the Vmin-potentiometer. The setting of...

 Open the catalog to page 9
TVJ-Easy/TVT-Easy-10

Characteristics · Wiring Examples Characteristics of the control signal (Example) ‡min unit 8 Actual value signal U Characteristic of actual value signal Flow rate Flow rate Variable flow rate control Room temperature controller The connection of supply voltage and of the external room temperature controller must be carried out as shown in the circuit diagram opposite. i.e. transmission to the next controller Constant flow rate control As soon as the 24 V supply voltage is applied, the controller runs the set ‡min-value as a constant flow rate. . . Vmin / Vmax changeover The switch S1 enables...

 Open the catalog to page 10
TVJ-Easy/TVT-Easy-11

Order Details Specification text Make: TROX. VAV rectangular controller Type TVJ-Easy or TVT-Easy (for low leakage shut-off) for variable air volume flow systems, for supply air or extract air, in 39 sizes. Selection based on duct dimensions. Simple setting by the customers of the volume flow with ‡min- and ‡max-adjustment potentiometers with percentage scales. During the installation or commissioning of controller, adjustment is possible without supply voltage. A transparent protection cover prevents inadvertent resetting and provides general security. Control damper blade delivery is in 45°...

 Open the catalog to page 11

All TROX catalogs and technical brochures

  1. Retrofit kits

    6  Pages

  2. X-GRILLE Cover

    18  Pages

  3. ATVC-100

    8  Pages

  4. X-CUBE Compact

    12  Pages

  5. ARR

    2  Pages

  6. VMRK

    4  Pages

  7. VFR

    8  Pages

  8. Tunnel dampers

    20  Pages

  9. FKS-EU

    20  Pages

  10. CAK

    6  Pages

  11. Type ST · XT

    8  Pages

  12. Type NL

    8  Pages

  13. Type PKV

    7  Pages

  14. Type BID

    8  Pages

  15. Type QLI

    8  Pages

  16. LVC

    9  Pages

  17. RM-O-3-D

    7  Pages

  18. RM-O-VS-D

    7  Pages

  19. FK-EU

    56  Pages

  20. EK-01

    14  Pages

  21. XSA

    12  Pages

  22. MSA

    12  Pages

  23. SCHOOLAIR-V

    12  Pages

  24. SCHOOLAIR-B

    12  Pages

  25. FSL-B-SEK

    4  Pages

  26. DID632

    20  Pages

  27. DID300B

    12  Pages

  28. DID312

    16  Pages

  29. AGW

    24  Pages

  30. AGS

    24  Pages

  31. DLQ-1...4-AK

    13  Pages

  32. DQ/ADQ

    9  Pages

  33. DLQ/ADLQ

    10  Pages

  34. DLK-Fb

    4  Pages

  35. VD

    10  Pages

  36. QSH · ISH

    8  Pages

  37. DLQL

    12  Pages

  38. X-CUBE

    16  Pages

  39. FV-K90

    12  Pages

  40. AK-Ex

    5  Pages

  41. JZ-RS

    5  Pages

  42. FKRS-EU

    28  Pages

  43. Star Climate

    16  Pages

  44. SD

    10  Pages

  45. AIRNAMIC

    12  Pages

  46. XARTO

    12  Pages

  47. X-CUBE COMPACT

    10  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.