Type TVJ-Easy • TVT-Easy

Open the catalog to page 1
TVJ-Easy/TVT-Easy - 2

Contents Innovation Construction · Dimensions Dimensions Technical data · Nomenclature Selection of dimensions Select dimensions Acoustic quick selection Flow rate adjustment Characteristics · Wiring examples Order details Green light: Ready!

Open the catalog to page 2
TVJ-Easy/TVT-Easy - 3

Innovation TROX TVJ-/TVT-Easy – the innovative solution ½ Easy ½ Easy Selection according to duct dimensions Functional testing with service button Flow rate adjustment without adjustment tool Functional check by indicator light The proven technology of the compact flow rate controller has been optimized. Valuable on site time saved by simple set up. TVJ-/TVT-Easy, developed with consultants and customers! ᕡ Differential pressure grid · Control damper blade ᕣ Flow rate scale ᕤ TROX Compact-controller ᕥ Connection terminals ᕦ Service button position indicator ᕩ Potentiometers ‡min µ...

Open the catalog to page 3
TVJ-Easy/TVT-Easy - 4

Construction · Dimensions – For delivery, control damper blade in 45° position – Flange both ends, suitable for fitting system 30 connecting profiles – Casing air leakage flow rate complies with DIN EN 1751, class A – The mechanical components are maintenance-free – Operating temperature range 10 to 50 °C – Storage temperature range –20 to +80 °C Characteristics – Electronic flow rate control – Green indicator light provides functional information: permantently on = set blinking = not set off = no supply voltage – Functional testing as follows: Press service button for at least 1 second...

Open the catalog to page 4
TVJ-Easy/TVT-Easy - 6

Technical Data · Nomenclature TROX Compact-controller technical data Supply voltage: Power rating: Control signal: Flow rate actual value signal: Transducer range: Running time: Torque: Safety class: Protection level: 24 VAC ± 20 %, 50/60 Hz or 24 VDC ± 10 % max. 5 VA (for a.c. voltage) max. 3 W (for d.c. voltage) 0 to 10 VDC, Ri > 100 kΩ 0 to 10 VDC linear, max. 0.5 mA 2 to 300 Pa 120 to 300 sec. for 87° 15 Nm III (Save voltage) min. IP 20 Additional safety requirements for the TROX Compact-controller – Installation and assembly must be performed by qualified personnel. Assembly must be...

Open the catalog to page 6
TVJ-Easy/TVT-Easy - 7

Selection of Dimensions The selection of the dimensions takes place according to the flow rate range specified by the consultant. Minimum total pressure differentials and flow rate tolerance The accurate adjustment of the flow rate setpoints is carried out using a flow rate scale, which is attached on each controller. For the acoustic characteristics in tables on page 8, duct air velocity is needed. This can be determined from the following table. 1) Additional factor to be taken into account Flow rate ranges . Vmin unit2) Dimensions H = 600, 800 and 1000 only available as TVJ-/TVJD-Easy!...

Open the catalog to page 7
TVJ-Easy/TVT-Easy - 8

Acoustic Quick Selection 1) 4 dB/octave ceiling reduction and 5 dB/octave room attenuation have been allowed for in the calculation of case-radiated noise. Acoustic data for differential pressure up to 1000 Pa, see on-line design programme "Air terminal units". Please refer to leaflet no. 5/4/EN/.. for acoustic performance data and selection example.

Open the catalog to page 8
TVJ-Easy/TVT-Easy - 9

Flow Rate Adjustment On each 7VJ-/TVT-Easy, a flow rate scale is available in order to determine the settings on site (see example size 500 x 200). Variable flow rate control The required flow rates must be adjusted by the customer. If \/min is set higher than \/max, then \/min is provided as a constant flow rate, even if a control signal is transmitted. If \/min is set on 0 %, then control is between shut-off and \/max. If the control signal falls below 0.1 VDC, the control damper closes. Constant flow rate control The constant flow rate can be set with the Vmin-potentiometer. The setting...

Open the catalog to page 9
TVJ-Easy/TVT-Easy - 10

Characteristics · Wiring Examples Characteristics of the control signal (Example) ‡min unit 8 Actual value signal U Characteristic of actual value signal Flow rate Flow rate Variable flow rate control Room temperature controller The connection of supply voltage and of the external room temperature controller must be carried out as shown in the circuit diagram opposite. i.e. transmission to the next controller Constant flow rate control As soon as the 24 V supply voltage is applied, the controller runs the set ‡min-value as a constant flow rate. . . Vmin / Vmax changeover The switch S1...

Open the catalog to page 10
TVJ-Easy/TVT-Easy - 11

Order Details Specification text Make: TROX. VAV rectangular controller Type TVJ-Easy or TVT-Easy (for low leakage shut-off) for variable air volume flow systems, for supply air or extract air, in 39 sizes. Selection based on duct dimensions. Simple setting by the customers of the volume flow with ‡min- and ‡max-adjustment potentiometers with percentage scales. During the installation or commissioning of controller, adjustment is possible without supply voltage. A transparent protection cover prevents inadvertent resetting and provides general security. Control damper blade delivery is in...

Open the catalog to page 11

All TROX catalogs and technical brochures

  1. X-GRILLE Cover

    18 Pages

  2. ATVC-100

    8 Pages

  3. X-CUBE Compact

    12 Pages

  4. ARR

    2 Pages

  5. VMRK

    4 Pages

  6. VFR

    8 Pages

  7. Tunnel dampers

    20 Pages

  8. FKS-EU

    20 Pages

  9. CAK

    6 Pages

  10. Type NL

    8 Pages

  11. Type PKV

    7 Pages

  12. Type BID

    8 Pages

  13. Type QLI

    8 Pages

  14. LVC

    9 Pages

  15. RM-O-3-D

    7 Pages

  16. RM-O-VS-D

    7 Pages

  17. FK-EU

    56 Pages

  18. EK-01

    14 Pages

  19. XSA

    12 Pages

  20. MSA

    12 Pages

  21. SCHOOLAIR-V

    12 Pages

  22. SCHOOLAIR-B

    12 Pages

  23. FSL-B-SEK

    4 Pages

  24. DID632

    20 Pages

  25. DID300B

    12 Pages

  26. DID312

    16 Pages

  27. AGW

    24 Pages

  28. AGS

    24 Pages

  29. DLQ-1...4-AK

    13 Pages

  30. DQ/ADQ

    9 Pages

  31. DLQ/ADLQ

    10 Pages

  32. DLK-Fb

    4 Pages

  33. VD

    10 Pages

  34. QSH · ISH

    8 Pages

  35. DLQL

    12 Pages

  36. X-CUBE

    16 Pages

  37. FV-K90

    12 Pages

  38. AK-Ex

    5 Pages

  39. JZ-RS

    5 Pages

  40. FKRS-EU

    28 Pages

  41. Star Climate

    16 Pages

  42. SD

    10 Pages

  43. AIRNAMIC

    12 Pages

  44. XARTO

    12 Pages

  45. X-CUBE COMPACT

    10 Pages

Archived catalogs

  1. Slot Diffuser

    11 Pages