Catalog excerpts
Type TVJ-Easy • TVT-Easy
Open the catalog to page 1Contents Innovation Construction · Dimensions Dimensions Technical data · Nomenclature Selection of dimensions Select dimensions Acoustic quick selection Flow rate adjustment Characteristics · Wiring examples Order details Green light: Ready!
Open the catalog to page 2Innovation TROX TVJ-/TVT-Easy – the innovative solution ½ Easy ½ Easy Selection according to duct dimensions Functional testing with service button Flow rate adjustment without adjustment tool Functional check by indicator light The proven technology of the compact flow rate controller has been optimized. Valuable on site time saved by simple set up. TVJ-/TVT-Easy, developed with consultants and customers! ᕡ Differential pressure grid · Control damper blade ᕣ Flow rate scale ᕤ TROX Compact-controller ᕥ Connection terminals ᕦ Service button position indicator ᕩ Potentiometers ‡min µ...
Open the catalog to page 3Construction · Dimensions – For delivery, control damper blade in 45° position – Flange both ends, suitable for fitting system 30 connecting profiles – Casing air leakage flow rate complies with DIN EN 1751, class A – The mechanical components are maintenance-free – Operating temperature range 10 to 50 °C – Storage temperature range –20 to +80 °C Characteristics – Electronic flow rate control – Green indicator light provides functional information: permantently on = set blinking = not set off = no supply voltage – Functional testing as follows: Press service button for at least 1 second...
Open the catalog to page 4Technical Data · Nomenclature TROX Compact-controller technical data Supply voltage: Power rating: Control signal: Flow rate actual value signal: Transducer range: Running time: Torque: Safety class: Protection level: 24 VAC ± 20 %, 50/60 Hz or 24 VDC ± 10 % max. 5 VA (for a.c. voltage) max. 3 W (for d.c. voltage) 0 to 10 VDC, Ri > 100 kΩ 0 to 10 VDC linear, max. 0.5 mA 2 to 300 Pa 120 to 300 sec. for 87° 15 Nm III (Save voltage) min. IP 20 Additional safety requirements for the TROX Compact-controller – Installation and assembly must be performed by qualified personnel. Assembly must be...
Open the catalog to page 6Selection of Dimensions The selection of the dimensions takes place according to the flow rate range specified by the consultant. Minimum total pressure differentials and flow rate tolerance The accurate adjustment of the flow rate setpoints is carried out using a flow rate scale, which is attached on each controller. For the acoustic characteristics in tables on page 8, duct air velocity is needed. This can be determined from the following table. 1) Additional factor to be taken into account Flow rate ranges . Vmin unit2) Dimensions H = 600, 800 and 1000 only available as TVJ-/TVJD-Easy!...
Open the catalog to page 7Acoustic Quick Selection 1) 4 dB/octave ceiling reduction and 5 dB/octave room attenuation have been allowed for in the calculation of case-radiated noise. Acoustic data for differential pressure up to 1000 Pa, see on-line design programme "Air terminal units". Please refer to leaflet no. 5/4/EN/.. for acoustic performance data and selection example.
Open the catalog to page 8Flow Rate Adjustment On each 7VJ-/TVT-Easy, a flow rate scale is available in order to determine the settings on site (see example size 500 x 200). Variable flow rate control The required flow rates must be adjusted by the customer. If \/min is set higher than \/max, then \/min is provided as a constant flow rate, even if a control signal is transmitted. If \/min is set on 0 %, then control is between shut-off and \/max. If the control signal falls below 0.1 VDC, the control damper closes. Constant flow rate control The constant flow rate can be set with the Vmin-potentiometer. The setting...
Open the catalog to page 9Characteristics · Wiring Examples Characteristics of the control signal (Example) ‡min unit 8 Actual value signal U Characteristic of actual value signal Flow rate Flow rate Variable flow rate control Room temperature controller The connection of supply voltage and of the external room temperature controller must be carried out as shown in the circuit diagram opposite. i.e. transmission to the next controller Constant flow rate control As soon as the 24 V supply voltage is applied, the controller runs the set ‡min-value as a constant flow rate. . . Vmin / Vmax changeover The switch S1...
Open the catalog to page 10Order Details Specification text Make: TROX. VAV rectangular controller Type TVJ-Easy or TVT-Easy (for low leakage shut-off) for variable air volume flow systems, for supply air or extract air, in 39 sizes. Selection based on duct dimensions. Simple setting by the customers of the volume flow with ‡min- and ‡max-adjustment potentiometers with percentage scales. During the installation or commissioning of controller, adjustment is possible without supply voltage. A transparent protection cover prevents inadvertent resetting and provides general security. Control damper blade delivery is in...
Open the catalog to page 11All TROX catalogs and technical brochures
-
Retrofit kits
6 Pages
-
X-GRILLE Cover
18 Pages
-
QUICK SELECTION GUIDE 2019 - 2
804 Pages
-
QUICK SELECTION GUIDE 2019 - 1
530 Pages
-
ATVC-100
8 Pages
-
X-CUBE Compact
12 Pages
-
X-CUBE RUN AROUND COIL SYSTEM
10 Pages
-
Air-water systems
307 Pages
-
ARR
2 Pages
-
WT · WL · EL
8 Pages
-
VMRK
4 Pages
-
VFR
8 Pages
-
Tunnel dampers
20 Pages
-
FKS-EU
20 Pages
-
CAK
6 Pages
-
Type ST · XT
8 Pages
-
Type ARK · ARK1
8 Pages
-
Type NL
8 Pages
-
Type JZ · JNE · JZ-L · JZD-G
20 Pages
-
Type FSL-B-ZAB
4 Pages
-
Type PKV
7 Pages
-
Type BID
8 Pages
-
Type QLI
8 Pages
-
LVC
9 Pages
-
RM-O-3-D
7 Pages
-
RM-O-VS-D
7 Pages
-
FK-EU
56 Pages
-
EK-01
14 Pages
-
XSA
12 Pages
-
MSA
12 Pages
-
SCHOOLAIR-V
12 Pages
-
SCHOOLAIR-B
12 Pages
-
FSL-B-SEK
4 Pages
-
DID632
20 Pages
-
DID300B
12 Pages
-
DID312
16 Pages
-
AGW
24 Pages
-
AGS
24 Pages
-
DLQ-1...4-AK
13 Pages
-
DQ/ADQ
9 Pages
-
DLQ/ADLQ
10 Pages
-
DLK-Fb
4 Pages
-
VD
10 Pages
-
QSH · ISH
8 Pages
-
DLQL
12 Pages
-
X-CUBE
16 Pages
-
FV-K90
12 Pages
-
TVR-Ex _ TES/TEF
7 Pages
-
AK-Ex
5 Pages
-
JZ-RS
5 Pages
-
FKRS-EU
28 Pages
-
Multileaf Dampers
8 Pages
-
Star Climate
16 Pages
-
X-GRILLE-Basic
4 Pages
-
X-GRILLE-Basic
3 Pages
-
Jet nozzles TJN
3 Pages
-
ARCHITECTURE NEEDS TO BREATHE
16 Pages
-
SD
10 Pages
-
AIRNAMIC
12 Pages
-
XARTO
12 Pages
-
X-CUBE COMPACT
10 Pages
Archived catalogs
-
Displacement Flow Diffusers
32 Pages
-
Product Summary
7 Pages
-
Quick selection guide
48 Pages
-
Air-water systems Design manual
60 Pages
-
Slot Diffuser
11 Pages
-
Passive Chilled Beams
7 Pages
-
Swirl Diffusers
17 Pages
-
Grilles/Linear Grilles
24 Pages
-
Swirl Diffusers Type FDE
6 Pages
-
Swirl Diffuser Type VDW
20 Pages
-
The art of handling air
80 Pages