1. Catalogs
  2. TROX
  3. Swirl Diffuser Type VDW
video corpo

Swirl Diffuser Type VDW
1 /20Pages

Swirl Diffuser Type VDW

Swirl Diffuser Type VDW
1 /20Pages

Catalog excerpts

Swirl Diffuser Type VDW-1

2/7/EN/6 Swirl Diffuser Type VDW recommended for room heights from approx. 2.60 ... 4.00 m

 Open the catalog to page 1
Swirl Diffuser Type VDW-2

Description 2Discharge Characteristics > In addition to the existing range of TROX swirl diffusers, thetype VDW swirl diffuser with manual adjustment has been developed. This enables the direction of discharge to be altered on site to cater for changes in room layout or partitions. Due to the rotary swirling motion of the air discharge, induction of roomair occurs very quickly, resulting in a rapid decay of supply air velocity and temperature differential. Air change rates of 30 per hour can be achieved with supply air temperature differentials of +10K to ז10K. The diffuser can be supplied with...

 Open the catalog to page 2
Swirl Diffuser Type VDW-3

The flow visualisation opposite shows the air dischargecharacteristics, control blades set for internal swirl. > External swirlVerticalInternal swirl(normal position)air discharge > for sizes 300x8, 400x16, 500x24, 600x24 and 625x24 All air control bladesAir control blades setAir control blades in each quartile ofset to external swirlhalf to external andface are set in the same direction, adjacenthalf internal to swirlquartiles set one internal one external swirl >

 Open the catalog to page 3
Swirl Diffuser Type VDW-4

300 298 600625 598 623 400 398 Test nipple Inclined manometer Plastic tube Code White sheathed cable damper open Diffuser face > 500 498 Green sheathed cable damper closed Plenum box >

 Open the catalog to page 4
Swirl Diffuser Type VDW-6

The face plate is in galvanised sheet steel. The surfaces arepre-treated and powder coated white (RAL9010).The control blades are made from Polystyrol (PS 476L),with black (similar to RAL 9005) as standard or white (similar to RAL 9010) on request.The plenum box is made from galvanised sheet steel, therubber lip seal. All sizes are suitable for flush mounting into a ceiling.If the diffuser is installed below a closed ceiling (i.e. freelysuspended) a stable discharge can be achieved if a peripheral collar 50 mm is provided available onrequest. > The plenum box is suspended using wires or slotted...

 Open the catalog to page 6
Swirl Diffuser Type VDW-7

Vin l/s:Supply air volume per diffuserV׷in m > 3 /h:Supply air volume per diffuserA, Bin m:Spacing between two diffusers Xin m:Distance between diffuser centre and wallH > 1 in m:Distance between ceiling and occupied zonev- > H1 in m/s:Time average air velocity between two diffusersat distance from ceiling H > 1 Lin m:Horizontal + vertical distance (X+H > 1 )discharge to the wallv- > L in m/s:Time average air velocity at wall t > Z in K:Temperature difference between supply airand room air t > L in K:Difference between core and room temperatureat distanceL = A/2 + H > 1 orL = B/2 + H > 1 orL...

 Open the catalog to page 7
Swirl Diffuser Type VDW-9

in Pa t p in Pa t p Pressure drop Pressure drop in Pa t p in Pa t p Pressure drop Pressure drop

 Open the catalog to page 9
Swirl Diffuser Type VDW-10

15010070 2010720305070150l/s100150200300400m 15010070 201074070100200300l/s200300400500m in Pa in Pa t t 5030 500 5030 900 p p in dB(A) L WA in dB(A) 202530354045L Pressure drop WA Pressure drop L 15 1540 10040 1540 15050 202530354045L 20253035404550 WNC 15 253035404550 WNC 200 400 3 /hV 3 /hV׷ 7001200

 Open the catalog to page 10
Swirl Diffuser Type VDW-11

100702010750070100200300l/s4002200300500m 1007020107500100200300l/s40022003000500m 5030 1200 5030 1200 in Pa in Pa t t p p in dB(A) 1540 150 in dB(A) L WA 1540 150700 WA Pressure drop 202530354045L Pressure drop 202530354045L L 253035404550 15 253035404550 15 20 20 WNC WNC 700 1000 3 /hV׷ 90016004 3 /hV 90016004

 Open the catalog to page 11
Swirl Diffuser Type VDW-12

Size Size in Pa in Pa t t p p Pressure drop Pressure drop Size Size in Pa in Pa t t p p Pressure drop Pressure drop

 Open the catalog to page 12
Swirl Diffuser Type VDW-13

Correction!For an installation below a continuous ceiling, the valuesv > L , and t > L / t > Z must be multiplied by a factor of 0.71! > Diffuser arrangement: Temperature Quotientsingle row or more than one row ifB 4.00 m Z t / L t Temperature Quotient Spacing A Distance L Diffuser arrangement: Square diffusermore than one row if B = 3.00 m Spacing A Spacing A 13 >

 Open the catalog to page 13
Swirl Diffuser Type VDW-14

Correction!For an installation below a continuous ceiling, the valuesv > L , and t > L / t > Z must be multiplied by a factor of 0.71! > Diffuser arrangement: Temperature Quotientsingle row or more than one row if B 4.00 m Z t / L t Temperature Quotient Spacing A Distance L Diffuser arrangement: Square diffusermore than one row if B = 3.00 m Spacing A Spacing A or B 14 >

 Open the catalog to page 14
Swirl Diffuser Type VDW-15

Correction!For an installation below a continuous ceiling, the valuesv > L , and t > L / t > Z must be multiplied by a factor of 0.71! > Diffuser arrangement: Temperature Quotientsingle row or more than one row if B 4.00 m Z t / L t Temperature Quotient Spacing A Distance L Diffuser arrangement: Square diffusermore than one row if B = 3.00 m Spacing A Spacing A 15 >

 Open the catalog to page 15
Swirl Diffuser Type VDW-16

L should not exceed0.2 m/s. The regenerated noise level of each diffuser is limited to L Data given:A hall measuring BxLxH = 24mx24mx3.40m is to be designed using VDW swirl diffusers for supply air.Total volume flow rateV=16000 l/s (57600 m > WA = 30 dB(A).Initial observation:Since the diffusers have to be arranged at a distance of X = 3 m from the external facade, the remaining area available for installation is 18 m x 18 m. Consider a distance between rows B = 3.0 m This results in 7 rowsV׷per row = 16000 l/s 2280 l/s7For spacing of diffusers along the rows select A = 1.0 m.This results in...

 Open the catalog to page 16
Swirl Diffuser Type VDW-17

Diagram 11:Sound power level and pressure dropL > WA =27 dB(A) (L > WNC = 21 NC) p > t =12 PaDiagram 36:Square diffuser: more than one rowif B = 3.00 mH > 1 =H 1.70 = 1.70 mv > H1 =0.17 m/sDiagram 37:Temperature QuotientL=H > 1 + A/2 = 2.20 mbetween two diffusers t > L / t > Z =0.05 t > L =֖ 8 x 0.05 = 0,4 KL=H > 1 + X = 4.70 mat the wallv > L =0.18 m/s t > L / t > Z =0.023 t > L =֖ 8 x 0.023 = 0.2 K Result:133 off VDW- Q - Z - H / 600x24 At the required air change rate of 30 per hour, the noiselevel requirements are met and the limiting air velocities not exceeded. Correction!For an installation...

 Open the catalog to page 17
Swirl Diffuser Type VDW-18

Correction!For an installation below a continuous ceiling, the valuesv > L , and t > L / t > Z must be multiplied by a factor of 0.71!For adjustment of blade rings for external swirl, the diagram values must be multiplied by 1.25! > Diffuser arrangement: Temperature Quotientsingle row or more than one row if B 4.00 m Z t / L t Temperature Quotient Spacing A Distance L Diffuser arrangement: Square diffusermore than one row if B = 3.00 m Spacing A Spacing A or B 18 >

 Open the catalog to page 18

All TROX catalogs and technical brochures

  1. Retrofit kits

    6  Pages

  2. X-GRILLE Cover

    18  Pages

  3. ATVC-100

    8  Pages

  4. X-CUBE Compact

    12  Pages

  5. ARR

    2  Pages

  6. VMRK

    4  Pages

  7. VFR

    8  Pages

  8. Tunnel dampers

    20  Pages

  9. FKS-EU

    20  Pages

  10. CAK

    6  Pages

  11. Type ST · XT

    8  Pages

  12. Type NL

    8  Pages

  13. Type PKV

    7  Pages

  14. Type BID

    8  Pages

  15. Type QLI

    8  Pages

  16. LVC

    9  Pages

  17. RM-O-3-D

    7  Pages

  18. RM-O-VS-D

    7  Pages

  19. FK-EU

    56  Pages

  20. EK-01

    14  Pages

  21. XSA

    12  Pages

  22. MSA

    12  Pages

  23. SCHOOLAIR-V

    12  Pages

  24. SCHOOLAIR-B

    12  Pages

  25. FSL-B-SEK

    4  Pages

  26. DID632

    20  Pages

  27. DID300B

    12  Pages

  28. DID312

    16  Pages

  29. AGW

    24  Pages

  30. AGS

    24  Pages

  31. DLQ-1...4-AK

    13  Pages

  32. DQ/ADQ

    9  Pages

  33. DLQ/ADLQ

    10  Pages

  34. DLK-Fb

    4  Pages

  35. VD

    10  Pages

  36. QSH · ISH

    8  Pages

  37. DLQL

    12  Pages

  38. X-CUBE

    16  Pages

  39. FV-K90

    12  Pages

  40. AK-Ex

    5  Pages

  41. JZ-RS

    5  Pages

  42. FKRS-EU

    28  Pages

  43. Star Climate

    16  Pages

  44. SD

    10  Pages

  45. AIRNAMIC

    12  Pages

  46. XARTO

    12  Pages

  47. X-CUBE COMPACT

    10  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.