Quick selection guide
48Pages

{{requestButtons}}

Catalog excerpts

Quick selection guide - 1

Quick Selection 2nd extended edition The art of handling air TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn www.troxtechnik.com

Open the catalog to page 1
Quick selection guide - 2

3 Register Product Type Page 1.1 Grilles ASL · SL · AT · TR · VAT · TRS 7 Grilles for rectangular or circular ducts TRS-K · TRS-R 8 1.2 Disc Valves LVS · Z-LVS 9 Jet Nozzles DUK 10 1.3 Floor Diffusers FB 11 2.1 Slot Diffusers VSD15 12 Slot Diffusers VSD35 13 – 14 Slot Diffusers VSD50 15 – 16 2.2 Swirl Diffusers RFD 17 Swirl Diffusers DCS 18 Swirl Diffusers FD 19 Swirl Diffusers TDF-SA 20 Swirl Diffusers VDW 21 Swirl Diffusers TDV-SA 22 Swirl Diffusers VDL 23 2.3 Ceiling Diffusers VDR 24 Ceiling Diffusers DLQ 25 2.4 Ceiling Diffusers DLQL 26 Ceiling Diffusers ADLR 27 3.1 Multileaf Dampers...

Open the catalog to page 2
Quick selection guide - 3

4 Why Quick Selection? This Quick Selection Guide was designed to help you select the products you require quickly and easily. It provides an overview of the various product designs and dimensions for selected TROX products. Full product and system details can be found on our website www.troxtechnik.com, on CD ROM, and in our technical leaflets and catalogues Klima 1, Klima 2 and Filter. TROX Products for ventilation and air conditioning technology: Components • Air terminal devices • Air terminal units • Fire and smoke protection components • Sound attenuators • Dampers and external...

Open the catalog to page 3
Quick selection guide - 4

5 Introduction In ventilation technology, two criteria are of particular importance: • the air velocity in the occupied zone and • the sound pressure level in the room Air velocity The air velocity depends on variables such as • flow rate in combination with type and size of the diffuser • arrangement of the diffusers within the room • the height of the room The flow pattern provided by the diffuser (swirl, linear or displacement) also influences the maximum possible air change rate. Drafts are caused by excessive air velocity in the occupied zone. The configuration tables in this Quick...

Open the catalog to page 4
Quick selection guide - 5

6 Application The table below provides an overview of the TROX products to be used depending on the air change rates per hour. Legend KVS Constant volume system VVS Variable volume system ++ very suitable + suitable – unsuitable * flow discharge alternating horizontal! Room height up to 4 m Air change Flow Slot Swirl Blade Perforated rates/h rate Grille diffuser diffuser diffuser diffuser control 10 KVS ++ ++ ++ ++ ++ VVS + + ++ + + 10 – 20 KVS – ++* ++ ++ ++ VVS – ++* ++ + + 20 – 30 KVS – – ++ – – VVS – – ++ – –

Open the catalog to page 5
Quick selection guide - 6

7 Grilles Type ASL · SL · AT · TR · VAT · TRS ASL SL Basic construction A without rear assembly ASL-A /SL-A AT-A/ TR-A VAT-A/ TRS-A Constructions with rear assembly -AG -D -AS -DG TR TRS AT VAT Flow rate and throw distance H x L Order Code AT - AG 825 x 225 A1 B11 P1 RAL 9016 These codes need not be completed for standard products / / / / / Type ASL AT VAT SL TR TRS Basic construction A AG Rear DG assemblies D AS L x H Fixing variants1) Specify RAL colour ASL, AT, VAT (Aluminium) 0 Standard finish E6-C-0 P0 Powder coating to RAL 9010 (GE 50 %)2) P1 Powder coating to RAL 9006 (GE 30 %)2)...

Open the catalog to page 6
Quick selection guide - 7

8 Flow rate and throw distance Order Code TRS - K5 825 x 125 A1 0 P1 RAL 9016 These codes need not be completed for standard products / / / / / Type TRS-K TRS-K5 TRS-KA TRS-KD TRS-KS Type TRS-R TRS-R5 TRS-RA TRS-RD TRS-RS L x H Not used Specify RAL colour 0 Standard galvanised surface P1 Powder coating to RAL 9006 (GE 30 %)1) other colours to RAL... (GE 70 %)1) 1) GE = Gloss level 2) only for Type TRS-K Type H Flow rate Length (mm) (mm) Throw distance 225 325 425 525 625 825 1025 1225 TRS-K/TRS-R 75 ‡min – ‡max 45...90 70…140 90…180 120…240 140…280 190…380 230…460 280…560 X (m) 1.5...3 2…4...

Open the catalog to page 7
Quick selection guide - 8

Dimensions (mm) 9 LVS Z-LVS Installation LVS Installation Z-LVS Flow rate LVS Size V . (m3/h) 100 110 125 180 160 250 200 360 Flow rate Z-LVS Size V . (m3/h) 100 100 125 160 160 230 200 280 Nomenclature ‡ in m3/h = Flow rate per air valve Note The sound power level is LWA 40 dB(A) in all cases. * Dimension “E” must be adjusted according to the ducts used. Type Supply air Z-LVS Extract air LVS Order Code Standard finish RAL 9010 LVS / 125 / 100 125 160 200 Size G1 IEEEEOEEEEP TEEEZEEEU 0 without subframe G1 subframe (Standard)1) 1) Unless otherwise specified on order, equipment is delivered...

Open the catalog to page 8
Quick selection guide - 9

Throw distance and pressure drop Dimensions (mm) 10 DUK DUK-F L2 ØD4 ØD3 ØD5 DUK-V Installation situation – isotherm – Size ØD1 ØD3 ØD4 ØD5 L1 L2 100 136 146 98 50 94 78 125 159 169 123 64 112 86 160 225 200 158 82 122 98 200 265 257 198 108 153 117 250 315 302 248 136 187 155 315 400 384 313 174 224 183 400 485 467 398 230 287 208 V . (m3/h) 75 100 150 250 400 600 800 1000 1250 1500 X (m) X (m) X (m) X (m) X (m) X (m) X (m) X (m) X (m) X (m) Size Äpt (Pa) Äpt (Pa) Äpt (Pa) Äpt (Pa) Äpt (Pa) Äpt (Pa) Äpt (Pa) Äpt (Pa) Äpt (Pa) Äpt (Pa) 100 8 11 50 100 125 6 9 11 25 50 100 160 5 6 9 12 10 20...

Open the catalog to page 9
Quick selection guide - 10

Dimensions (mm) 11 FB H ØR+48 ØR ØD K Adjustable swirl element V/H Trim ring Dirt trap and adjustable flow rate control SM/SV Plastic Type vertical horizontal V . max (m3/h) V . max (m3/h) FBK-150 100 50 FBK-200 135 90 Aluminium Type vertical horizontal V . max (m3/h) V . max (m3/h) FBA-150 110 60 FBA-200 135 90 Size ØD ØR K H 150 98 150 200 125 200 123 200 250 150 Sound power level is LWA 35 dB(A) in all cases Total pressure drop Äpt 40 Pa 600 mm 600 mm ÄtZ max = -6K ÄtZ max = -10K Mindestabstand Mindestabstand Discharge situation horizontal (displacement flow) Minimum distance comfort...

Open the catalog to page 10
Quick selection guide - 11

12 Slot Diffusers Type VSD15 VSD15-A VSD15-A-Z0 VSD15-D VSD15-D-Z0 182 Ø78 58 15 70 40 40 40 202 58 110 40 Ø78 15 VSD15 Nomenclature ‡ in m3/h = Flow rate X in m = Throw distance L1 in mm = Length of plenum box A in m = Distance between 2 diffusers ƒH1 in m/s = Time average upstream velocity between 2 diffusers ƒL in m/s = Time average upstream velocity at the wall Note Room height = 3 m ƒH1/ ƒL = 0.17 m/s Sound power level is LWA 35 dB(A) in all cases Pressure drop Äpt 30 Pa If desired, the length of the diffuser face can be greater than the length of the plenum box. Throw distance X (m) ·...

Open the catalog to page 11

All TROX catalogs and technical brochures

  1. X-GRILLE Cover

    18 Pages

  2. ATVC-100

    8 Pages

  3. X-CUBE Compact

    12 Pages

  4. ARR

    2 Pages

  5. VMRK

    4 Pages

  6. VFR

    8 Pages

  7. Tunnel dampers

    20 Pages

  8. FKS-EU

    20 Pages

  9. CAK

    6 Pages

  10. Type NL

    8 Pages

  11. Type PKV

    7 Pages

  12. Type BID

    8 Pages

  13. Type QLI

    8 Pages

  14. LVC

    9 Pages

  15. RM-O-3-D

    7 Pages

  16. RM-O-VS-D

    7 Pages

  17. FK-EU

    56 Pages

  18. EK-01

    14 Pages

  19. XSA

    12 Pages

  20. MSA

    12 Pages

  21. SCHOOLAIR-V

    12 Pages

  22. SCHOOLAIR-B

    12 Pages

  23. FSL-B-SEK

    4 Pages

  24. DID632

    20 Pages

  25. DID300B

    12 Pages

  26. DID312

    16 Pages

  27. AGW

    24 Pages

  28. AGS

    24 Pages

  29. DLQ-1...4-AK

    13 Pages

  30. DQ/ADQ

    9 Pages

  31. DLQ/ADLQ

    10 Pages

  32. DLK-Fb

    4 Pages

  33. VD

    10 Pages

  34. QSH · ISH

    8 Pages

  35. DLQL

    12 Pages

  36. X-CUBE

    16 Pages

  37. FV-K90

    12 Pages

  38. AK-Ex

    5 Pages

  39. JZ-RS

    5 Pages

  40. FKRS-EU

    28 Pages

  41. Star Climate

    16 Pages

  42. SD

    10 Pages

  43. AIRNAMIC

    12 Pages

  44. XARTO

    12 Pages

  45. X-CUBE COMPACT

    10 Pages

Archived catalogs

  1. Slot Diffuser

    11 Pages