Product catalog summary
Description
Air displacement vent units, types QSH and ISH, are designed for industrial areas with heights ranging from 3.5 to 10 meters. They can be installed freely suspended or fixed to columns or walls. These units can provide heating or cooling by discharging air horizontally or vertically. Type QSH is suitable for air-polluting processes due to its low turbulence air distribution, while type ISH is ideal for clean processes with a wider air throw.

Construction and Materials
The units are available in four sizes and consist of a perforated cylinder, an air control disc, and a base plate. They can be adjusted manually or automatically with an electric or thermal actuator. The materials include galvanized perforated sheet steel, with optional powder-coating for visible surfaces.

Installation
Units are installed directly into system ducting and can be wall-mounted using brackets. Manual adjustments can be made using a chain or Bowden cable, while electric actuators require no wiring for thermal models.

Nomenclature and Technical Data
Key parameters include volume flow, maximum horizontal throw, supply air temperature differential, and sound power level. The recommended supply air temperature differential is between -8K and +12K. Installation height should be at least 3.5 meters above the floor.

Order Details
Units can be customized with different actuators and finishes. The order code specifies the type, size, and additional features like wall frames or chain fixing.

Specification Text
The units are suitable for large halls requiring both heating and cooling. Type QSH is designed for low-turbulence air supply in polluted environments, while type ISH covers larger areas with high momentum air distribution. Adjustments can be manual or automatic, and materials are galvanized steel with optional powder-coating.
See more

Catalog excerpts

QSH · ISH-1

Air Displacement Vent Units Type QSH · ISH TROX GmbH Heinrich-Trox-Platz D-47504 Neukirchen-Vluyn

 Open the catalog to page 1
QSH · ISH-2

Contents · Description Description Construction · Dimensions Materials Installation Nomenclature Technical Data Order Details Aisle area For air-polluting work processes For clean work processes Description Air displacement vent units types QSH and ISH are mainly used in industrial areas with heights of 3.5 to 10 m, installation can be freely suspended or fixed to columns or walls. In rooms or halls with changing thermal loads the supply air temperature can provide either heating or cooling functions and the air itself can be discharged horizontally or vertically. Air polluting work processes...

 Open the catalog to page 2
QSH · ISH-3

Description When cooling (discharge of chilled air) the supply air has to be discharged horizontally in order to comply with the comfort criteria. When heating (discharge of warm air) the supply air has to be discharged vertically downwards, otherwise it would not reach the occupied zone due to thermal buoyancy effects. The air control disc can be adjusted either manually using a chain pull or Bowden cable, electrically with an actuator or by a self powered thermal actuator. Type ISH – cooling mode Type ISH – heating mode horizontal discharge vertical discharge Type QSH – cooling mode Type QSH...

 Open the catalog to page 3
QSH · ISH-4

Construction · Dimensions · Materials Construction Electrical wiring is not required for types QSH-T / ISH-T. Air displacement vent units types QSH and ISH are available in four sizes. They comprise a perforated cylinder with a formed circular spigot, an internal air control disc and a solid base plate. Materials Galvanised perforated sheet steel cylinder, galvanised sheet steel spigot, air control disc and base plate. Galvanised surface finish is standard. The adjustment of the air discharge direction can optionally either be by means of manual adjustment with a chain (QSH/ISH) or Bowden cable...

 Open the catalog to page 4
QSH · ISH-5

The units are installed directly into the system ducting and fixed by screws or rivets provided by others. The entire system must be securely fixed and suspended by appropriate means. The units can be fitted to walls or columns using the wall brackets which can be supplied on request (W00). The wall mounting frame is fixed by using bolts, after which the air displacement unit is located on the mounting frame from above and fitted to it using two screws. In the case of the chain pull, the chain fixing bracket (K00) is plug fixed and the chain length altered to achieve the required position of...

 Open the catalog to page 5
QSH · ISH-6

Nomenclature · Technical Data Nomenclature Below the unit air velocities in the occupied zone may deviate from the values required by DIN 1946/2 for comfort. Therefore, for example, installation above aisles is recommended. Volume flow per unit Volume flow per unit Maximum horizontal throw Supply air temperature differential Max. vertical penetration depth of jet in heating mode ƒL in m/s: Time average air velocity of 0.3 m/s ͬ pt in Pa: Total pressure drop LWA in dB(A): A-weighted sound power level Type ISH Air volocities in the occupied zone correspond to the values required by DIN 1946/2 for...

 Open the catalog to page 6
QSH · ISH-7

Maximum temperature differential Heating mode (vertical): Atmax = +12K Cooling mode (horizontal): A tmax = - 8K Recommended installation height above floor 3.5 m. Sound power level and pressure drop, type QSH Correction for vertical discharge (heating mode), diagram 1 Sound power level and pressure drop, type ISH Correction for vertical discharge (heating mode), diagram 2 Data given: Supply air temperature differential Atz = + 12 K Acceptable air velocity vL = approx. 0.3 m/s Diagram 2: Sound power level and pressure drop in cooling mode (horizontal) LWA = 48 dB(A) in heating mode (vertical)...

 Open the catalog to page 7
QSH · ISH-8

Order Details These codes do not need to be completed for standard products QSH - E2 With manual adjustment TQSH E ZISH E (chain pull) U Electrical actuator 230 V, 50 Hz Thermal actuator Bowden cable State colour 0 Standard finish galvanised P0 Powder-coated RAL 9010 (GE 50 %)1) P1 Powder-coated RAL ... (GE 70 %)1) With wall frame With chain fixing2) With wall frame and chain fixing2) GE = Gloss level ! 2) for manual adjustment only 1) Design changes reserved · All rights reserved © TROX GmbH (8/2008) Specification Text Air displacement vent unit in circular construction suitable for suspending...

 Open the catalog to page 8

All TROX catalogs and technical brochures

  1. Retrofit kits

    6  Pages

  2. X-GRILLE Cover

    18  Pages

  3. ATVC-100

    8  Pages

  4. X-CUBE Compact

    12  Pages

  5. ARR

    2  Pages

  6. VMRK

    4  Pages

  7. VFR

    8  Pages

  8. Tunnel dampers

    20  Pages

  9. FKS-EU

    20  Pages

  10. CAK

    6  Pages

  11. Type ST · XT

    8  Pages

  12. Type NL

    8  Pages

  13. Type PKV

    7  Pages

  14. Type BID

    8  Pages

  15. Type QLI

    8  Pages

  16. LVC

    9  Pages

  17. RM-O-3-D

    7  Pages

  18. RM-O-VS-D

    7  Pages

  19. FK-EU

    56  Pages

  20. EK-01

    14  Pages

  21. XSA

    12  Pages

  22. MSA

    12  Pages

  23. SCHOOLAIR-V

    12  Pages

  24. SCHOOLAIR-B

    12  Pages

  25. FSL-B-SEK

    4  Pages

  26. DID632

    20  Pages

  27. DID300B

    12  Pages

  28. DID312

    16  Pages

  29. AGW

    24  Pages

  30. AGS

    24  Pages

  31. DLQ-1...4-AK

    13  Pages

  32. DQ/ADQ

    9  Pages

  33. DLQ/ADLQ

    10  Pages

  34. DLK-Fb

    4  Pages

  35. VD

    10  Pages

  36. DLQL

    12  Pages

  37. X-CUBE

    16  Pages

  38. FV-K90

    12  Pages

  39. AK-Ex

    5  Pages

  40. JZ-RS

    5  Pages

  41. FKRS-EU

    28  Pages

  42. Star Climate

    16  Pages

  43. SD

    10  Pages

  44. AIRNAMIC

    12  Pages

  45. XARTO

    12  Pages

  46. X-CUBE COMPACT

    10  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.