Catalog excerpts

Passive Chilled Beams - 1

Chilled Beams TROX GmbH e-mail trox@trox.de

Open the catalog to page 1
Passive Chilled Beams - 2

Contents • Description Type PKV-R Passive chilled beams (without supply air) are used for dissipa- tion of high internal heat loads. The energy benefits by using water as a transport medium can in this product be fully utilised. In new buildings they offer low investment costs and high cooling capacity, and they are also the preferred option in refurbishment applications. Depending on the design brief for the room and its ceiling, the units can be installed flush in a false ceiling or can be freely They can be integrated with luminaires, speakers etc. We can offer an individual solution to...

Open the catalog to page 2
Passive Chilled Beams - 3

Constructions • Dimensions The type PKV passive chilled beam comprises a casing with optional frame, a cooling coil with connection flanges, and on request a perforated metal facing. Casing without frame has hanging brackets for use when When ordered with a frame (PKV-R), the unit can be supplied with nut serfs or on request with adjustable height hanging Casing and perforated metal facing are of galvanised steel sheet, frame (PKV-R) is of aluminium, cooling coil has copper tubes with formed aluminium fins and galvanised flanges. The standard surface finish of units without frames is black...

Open the catalog to page 3
Passive Chilled Beams - 4

It is essential for perfect convection that the air which has to be cooled down can flow unhindered into the coil. The best condition for this is when distance Z - lower edge of ceiling slab to upper edge of beam - is as large as possible The type PKV chilled beam is suspended with hanging brackets fixed on the sides of the casing. The type PKV-R chilled beam can be suspended either with height-adjustable hanging brackets or with fixed nut serfs. The chilled beam can be suspended from the ceiling slab with threaded rods or suspension wires. Type PKV • flush mounting Type PKV-R • freely...

Open the catalog to page 4
Passive Chilled Beams - 5

Reference values Water volume flow rate, cooling Water cooling capacity Specific cooling capacity per m Chilled water flow temperature Chilled water return temperature Chilled water mean temperature Temperature difference between water flow and return temperature Temperature difference between max. room air temperature and chilled water mean temperature Maximum time average air velocitiy measured approx. 1 m underneath the passive chilled beam Water-side pressure drop Free area of bottom perforated cover plate (100 % without perforated sheet metal) Correction factor for the relation Z to B...

Open the catalog to page 5
Passive Chilled Beams - 6

Technical data The exact match between the actual capacity and the required capacity can be achieved by adjusting the flow water temperature and / or the water flow rate. These will change the water-side Atw Water-side pressure drop All three chilled beams will be connected separately to the flow and return water Diagram VIII The air velocity 1 m below the passive chilled beam will be between 0.17 and Water-side cooling capacity QWK in W Water volume flow rate VWK in l/h measured approx. 1 m below the passive chilled beam. Water volume flow rate VWK in l/h Cooling capacity chilled beam in W/m

Open the catalog to page 6
Passive Chilled Beams - 7

Specification text Type PKV passive chilled beam is used to dissipate high internal heat loads. It comprises a casing, on request with aluminium frame for freely suspended installation, on request with perforated plate as front cover, and the cooling coil with flanges and aluminium Depending on the construction selected, suspension of the unit on site can be by hanging brackets, fixed nut serfs or height- adjustable brackets. Casing and perforated metal facing are of galvanised steel sheet, frame (PKV-R) is of aluminium, cooling coil has copper tubes with formed aluminium fins and...

Open the catalog to page 7

All TROX catalogs and technical brochures

  1. X-GRILLE Cover

    18 Pages

  2. ATVC-100

    8 Pages

  3. X-CUBE Compact

    12 Pages

  4. ARR

    2 Pages

  5. VMRK

    4 Pages

  6. VFR

    8 Pages

  7. Tunnel dampers

    20 Pages

  8. FKS-EU

    20 Pages

  9. CAK

    6 Pages

  10. Type NL

    8 Pages

  11. Type PKV

    7 Pages

  12. Type BID

    8 Pages

  13. Type QLI

    8 Pages

  14. LVC

    9 Pages

  15. RM-O-3-D

    7 Pages

  16. RM-O-VS-D

    7 Pages

  17. FK-EU

    56 Pages

  18. EK-01

    14 Pages

  19. XSA

    12 Pages

  20. MSA

    12 Pages

  21. SCHOOLAIR-V

    12 Pages

  22. SCHOOLAIR-B

    12 Pages

  23. FSL-B-SEK

    4 Pages

  24. DID632

    20 Pages

  25. DID300B

    12 Pages

  26. DID312

    16 Pages

  27. AGW

    24 Pages

  28. AGS

    24 Pages

  29. DLQ-1...4-AK

    13 Pages

  30. DQ/ADQ

    9 Pages

  31. DLQ/ADLQ

    10 Pages

  32. DLK-Fb

    4 Pages

  33. VD

    10 Pages

  34. QSH · ISH

    8 Pages

  35. DLQL

    12 Pages

  36. X-CUBE

    16 Pages

  37. FV-K90

    12 Pages

  38. AK-Ex

    5 Pages

  39. JZ-RS

    5 Pages

  40. FKRS-EU

    28 Pages

  41. Star Climate

    16 Pages

  42. SD

    10 Pages

  43. AIRNAMIC

    12 Pages

  44. XARTO

    12 Pages

  45. X-CUBE COMPACT

    10 Pages

Archived catalogs

  1. Slot Diffuser

    11 Pages