1. Catalogs
  2. TROX
  3. Multileaf Dampers
video corpo

Multileaf Dampers

Multileaf Dampers

Multileaf Dampers

Product catalog summary
Introduction
This document provides comprehensive information on multileaf dampers, including new product additions, specifications, and actuator options.
New Product Range
- Introduction of Type JNE-L, featuring stainless steel construction and air-tightness per DIN EN 1751.
- Expanded dimensions for Types JZ-G and JZD-G up to 1200 mm width.
- Availability of intermediate sizes within standard dimensions.
Specifications
- All types, except JZ-G and JZD-G, are available in both standard and intermediate sizes.
- Casing leakage for all types complies with DIN EN 1751, achieving classification C.
Actuator Options
- Various spring return actuators, plug-on actuators, and control drivers are available.
- Actuators have different power requirements, protection classes, and torque capacities.
- Options include actuators with and without integrated limit switches.
Technical Details
- Actuators operate on AC and DC voltages with varying power consumption and torque specifications.
- Protection classes range from II to III, with degrees of protection up to IP54.
- Running times for actuators vary, with some offering fast-running options.
Compliance and Standards
- Products comply with DIN EN 1751 for air-tightness and DIN 1946 for leakage standards.
- Minimum torque requirements are specified to ensure compliance with leakage standards.
Specifications
The document outlines specifications for various actuator types and multileaf dampers, specifying required actuators without considering aerodynamic influences. Types include JZ-A, JNE-A, JZ-B, JZD-B, JNE-B, JZ-G, JZD-G, JZ-L, and JNE-L. Actuators are categorized as size-independent or size-dependent, with specific torque requirements for electrical actuators.
Actuator Details
Electrical actuators for types JZ-L and JNE-L are detailed with torque specifications of 10 Nm, 20 Nm, and 30 Nm. A table provides height and width dimensions corresponding to different torque levels.
Order Codes and Variants
Order codes for multileaf dampers are provided, detailing construction variants, drive sides, nominal sizes, and additional features such as casing flanges, bearings, and surface finishes. Options for open or closed damper positions and powder-coated or anodized surfaces are specified.
Additional Information
The document mentions the availability of TROXNETCOM communication solutions for multileaf damper drives based on LON and AS-Interface. Further information and pricing details are available online and in specific leaflets.
See more

Catalog excerpts

Multileaf Dampers-1

Product Information on Multileaf Dampers • Type JNE-L (stainless steel construction, air tight to DIN EN 1751) • All types (except JZ-G · JZD-G) Within the standard sizes all intermediate sizes (width-dimension and/or height-dimension) deliverable. Multileaf dampers out of the standard sizes will be delivered subdivided on B- resp. H-dimension. • Types JZ-G · JZD-G Dimension range expanded up to width B = 1200 mm; all B-dimension-intermediale-sizes within the standard sizes are deliverable. Types JZ-B · JZD-B · JZ-L · JNE-B · JNE-L • Accessory spring return actuators, plug-on actuators and control drivers See table on page 2 to 6 • Accessory pneumatic actuators See product information PI/3/4/EN/2 • All types – Casing leakage (with multileaf damper opened) in accordance with DIN EN 1751 – Independent of size the classification C is fulfilled Design changes reserved · All rights reserved © TROX GmbH (3/2012)

 Open the catalog to page 1
Multileaf Dampers-2

Product Information on Multileaf Dampers PI/3/3/EN/2 Product range spring return actuators, plug-on actuators and control drives Type resp. construction variant … combined … Types Code Type resp. construction variant … combined … JZ-A JZ-B JZD-B JNE-A JNE-B Spring return actuator (power off to close), damper “CLOSED” when no current 4) – without integrated limit switches ZF02 U = AC 24...240 V, 50/60 Hz resp. DC 24...125 V, opening ≈ 6 W, in the open position ≈ 2.5 W, capacity 9.5 VA, protection class II totaly insulated, degree of protection IP54, opening ≤ 75 s, closing ≤ 20 s, torque min....

 Open the catalog to page 2
Multileaf Dampers-3

Product Information on Multileaf Dampers PI/3/3/EN/2 Product range spring return actuators, plug-on actuators and control drives OLD Type resp. construction variant … combined … Types JZ-A JZ-B JZD-B JNE-A JNE-B with integrated limit switches U = AC 24...240 V, 50/60 Hz resp. DC 24...125 V, opening ≈ 6 W, in the open position ≈ 2.5 W, capacity 9.5 VA, protection class II totaly insulated, degree of protection IP54, opening ≤ 75 s, closing ≤ 20 s, torque min. 10 Nm, Auxiliary switch: 2 x EPU, 1 mA...3 (0.5) A, AC 250 V, weight 2.2 kg with integrated limit switches U = AC 24...240 V, 50/60 Hz resp....

 Open the catalog to page 3
Multileaf Dampers-4

Product Information on Multileaf Dampers PI/3/3/EN/2 Product range spring return actuators, plug-on actuators and control drives OLD Type resp. construction variant … combined … NEW Type resp. construction variant … combined … without integrated limit switches ZF05 U = AC 24 V, 50/60 Hz resp. DC 24 V, opening ≈ 3.5 W, in the open position ≈ 2.5 W, capacity 5.5 VA, protection class III safety extra-low voltage, degree of protection IP54, opening ≤ 150 s, closing ≤ 20 s, torque min. 10 Nm, weight 1.8 kg without integrated limit switches ZS20 U = AC 24 V, 50/60 Hz resp. DC 24 V, opening ≈ 6 W, in...

 Open the catalog to page 4
Multileaf Dampers-5

Product Information on Multileaf Dampers PI/3/3/EN/2 Product range spring return actuators, plug-on actuators and control drives OLD Type resp. construction variant … combined … Types JZ-A JZ-B JZD-B JNE-A JNE-B U = AC 100…240 V, 50/60 Hz, P = 5 W, capacity 9 VA, protection class II, degree of protection IP54, running time approx. 150 s, torque min. 40 Nm U = AC 24 V, 50/60 Hz resp. DC 24 V, P = 1 W, capacity 2 VA, protection class III, degree of protection IP54, running time approx. 150 s, torque min. 5 Nm U = AC 24 V, 50/60 Hz resp. DC 24 V, P = 1.5 W, capacity 4 VA, protection class III, degree...

 Open the catalog to page 5
Multileaf Dampers-6

Product Information on Multileaf Dampers PI/3/3/EN/2 Product range spring return actuators, plug-on actuators and control drives Type resp. construction variant … combined … Types Code Type resp. construction variant … combined … JZ-A JZ-B JZD-B JNE-A JNE-B Plug-on actuator, open/close-reversible Z15 with auxiliary switch: 2 x EPU (single-pole double-throw switch), AC 250 V, 6 A (2.5 A), protection class II, degree of protection IP54 Z15 with auxiliary switch: 2 x EPU (single-pole double-throw switch), AC 250 V, 6 A (2.5 A), protection class II, degree of protection IP54 Plug-on actuator, open/close-reversible,...

 Open the catalog to page 6
Multileaf Dampers-7

Product Information on Multileaf Dampers PI/3/3/EN/2 Electrical actuators Required actuators (without taking account of aerodynamic influences) for types: – JZ-A · JNE-A · JZ-B · JZD-B · JNE-B · JZ-G · JZD-G one actuator (size-independent) – JZ-L · JNE-L one actuator (size-dependent) as per table Mode of drive Spring return actuator, plug-on actuator, open/close-reversible resp. control drive (torque min. 10 Nm), e. g. Z43 Spring return actuator, plug-on actuator, open/close-reversible resp. control drive (torque min. 20 Nm), e. g. Z14 Spring return actuator, plug-on actuator, open/close-reversible...

 Open the catalog to page 7
Multileaf Dampers-8

Product Information on Multileaf Dampers PI/3/3/EN/2 Order Code Types JZ-G · JZD-G JZ – G / 1000×1000 / 33 / Z64 / CLOSED / P1 / RAL ... Type Multileaf Damper JZ-G JZD-G Damper position OPEN pressureless/power-off open CLOSED pressureless/power-off closed (specification only required at spring return actuators, single-acting rotation cylinder resp. double-acting rotation cylinder with solenoid valve) Masonry subframe 0 without 33 with Surface P1 / RAL … powder-coated, specify the RAL CLASSIC shade S3 anodised to EURAS-standard E6-C-0 Additionally we are able to offer TROXNETCOM communication-solutions...

 Open the catalog to page 8

All TROX catalogs and technical brochures

  1. Retrofit kits

    6  Pages

  2. X-GRILLE Cover

    18  Pages

  3. ATVC-100

    8  Pages

  4. X-CUBE Compact

    12  Pages

  5. ARR

    2  Pages

  6. VMRK

    4  Pages

  7. VFR

    8  Pages

  8. Tunnel dampers

    20  Pages

  9. FKS-EU

    20  Pages

  10. CAK

    6  Pages

  11. Type ST · XT

    8  Pages

  12. Type NL

    8  Pages

  13. Type PKV

    7  Pages

  14. Type BID

    8  Pages

  15. Type QLI

    8  Pages

  16. LVC

    9  Pages

  17. RM-O-3-D

    7  Pages

  18. RM-O-VS-D

    7  Pages

  19. FK-EU

    56  Pages

  20. EK-01

    14  Pages

  21. XSA

    12  Pages

  22. MSA

    12  Pages

  23. SCHOOLAIR-V

    12  Pages

  24. SCHOOLAIR-B

    12  Pages

  25. FSL-B-SEK

    4  Pages

  26. DID632

    20  Pages

  27. DID300B

    12  Pages

  28. DID312

    16  Pages

  29. AGW

    24  Pages

  30. AGS

    24  Pages

  31. DLQ-1...4-AK

    13  Pages

  32. DQ/ADQ

    9  Pages

  33. DLQ/ADLQ

    10  Pages

  34. DLK-Fb

    4  Pages

  35. VD

    10  Pages

  36. QSH · ISH

    8  Pages

  37. DLQL

    12  Pages

  38. X-CUBE

    16  Pages

  39. FV-K90

    12  Pages

  40. AK-Ex

    5  Pages

  41. JZ-RS

    5  Pages

  42. FKRS-EU

    28  Pages

  43. Star Climate

    16  Pages

  44. SD

    10  Pages

  45. AIRNAMIC

    12  Pages

  46. XARTO

    12  Pages

  47. X-CUBE COMPACT

    10  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.