Product Information on Smoke Protection Dampers Type JZ-RS PI/4/17/EN/5 Smoke protection dampers of the type JZ-RS with general building approval Z-78.4-51 Application Smoke protection dampers are utilised for prevention of smoke transmission in ventilation control centres of air supply systems operated with recirculation or only with external air and for fire-protection-restructuring of old plants. The damper installation is independent of the air flow direction. The actuation is realised by spring return actuators. Smoke protection dampers are not suitable for undertaking the functions of fire dampers. Smoke protection dampers may only be used in conjunction with smoke detectors whose qualification for this application has been proven by a general building approval, e.g. TROX smoke detectors of the type RM-O-VS-D according to leaflet No. 4/6.2/EN/... Permanence Regulations Smoke protection dampers are items which require an offical licence for use (general building approval). Therefore, the “General and Special Provisions” specified in the general building approval must be followed when using the smoke protection dampers. The operator of the ventilation system must keep smoke protection dampers and associated smoke detectors constantly ready for operation and in good condition. In particular, the general maintenance guidelines according to DIN 31051 must be observed for preservation and, if necessary, for retrieval of the nominal condition. This applies to all safety related products. Supervision by an external organisation as required by the German law is performed by FMPA, Baden-Württemberg. – Smoke protection dampers must be maintained at least once a year. – The maintenance is to be recorded; the documents are to be retained by the operator of the ventilation system. The smoke protection dampers must be installed so that inspection, cleaning and repair of the components can be carried out easily in the installed status. This also applies to the connected smoke detectors, if necessary therefore revision-openings must be provided in the connected air ducts. Design changes reserved · All rigths reserved ȯ TROX GmbH (3/2012) Maintenance Regulations Accessibility
Open the catalog to page 1Product Information on Smoke Protection Dampers Type JZ-RS PI/4/17/EN/5 Standard Sizes Spring return actuator External linkage Angle blade stop (arranged on the B-sides) – Casing and blades made of profiled, galvanised sheet steel, casing flanges punched in the corners on both sides Seal steel sheet (arranged on the H-sides) – Blade spindles and external linkage made of galvanised steel – Angle blade stops (arranged on the B-sides) made of galvanised steel – Seal steel sheets (arranged on the H-sides) made of stainless steel – Bearing bushes made of brass – Opposed blade action Available...
Open the catalog to page 2Product Information on Smoke Protection Dampers Type JZ-RS PI/4/17/EN/5 Circuit- and Wiring Diagram for Smoke Protection Damper and Smoke Detector L Description of Function Opening in case of coventional operation Close electric circuit to the smoke detector Pos. (2) via the switch Pos. (1). The alarm relay of the smoke detector picks up and closes via the contact Pos. (8) the electric circuit to the load relay Pos. (3). The load relay picks up and closes the electric circuit to the spring return actuator Pos. (5) and to the ventilator Pos. (4). The smoke protection damper opens, the...
Open the catalog to page 3Product Information on Smoke Protection Dampers Type JZ-RS PI/4/17/EN/5 Product Range Note: Connection 24 V via safety transformer Accessories Type or construction variant combined with Spring return actuator (power off to close) Damper “CLOSED”, if no current – without integrated limit switches U = AC 24 V, 50/60 Hz / DC 24 V, opening ≈ 5 W, in the open position ≈ 2,5 W, capacity 7,5 VA, protection class III safety extra-low voltage, degree of protection IP54, opening ≤ 75 s, closing ≤ 20 s, weight 2,1 kg – without integrated limit switches U = AC 24...240 V, 50/60 Hz / DC 24...125 V,...
Open the catalog to page 4Product Information on Smoke Protection Dampers Type JZ-RS PI/4/17/EN/5 Order Code JZ – RS – G – R / 1000×1005 / 22 / ZF06 Type JZ-RS Smoke Protection Damper Masonry subframe 0 without 22 with Construction variant no entry: basic version G Casing both flanges drilled Drive side R right L left (if this is not specified then "R" is supplied) Nominal size [mm] B x H (see page 2) Additionally we are able to offer TROXNETCOM communication-solutions for the drive of smoke protection dampers based on LON and AS-Interface. Information are available on the Internet under Products/Automation and...
Open the catalog to page 5All TROX catalogs and technical brochures
-
Retrofit kits
6 Pages
-
X-GRILLE Cover
18 Pages
-
QUICK SELECTION GUIDE 2019 - 2
804 Pages
-
QUICK SELECTION GUIDE 2019 - 1
530 Pages
-
ATVC-100
8 Pages
-
X-CUBE Compact
12 Pages
-
X-CUBE RUN AROUND COIL SYSTEM
10 Pages
-
Air-water systems
307 Pages
-
ARR
2 Pages
-
WT · WL · EL
8 Pages
-
VMRK
4 Pages
-
VFR
8 Pages
-
Tunnel dampers
20 Pages
-
FKS-EU
20 Pages
-
CAK
6 Pages
-
Type ST · XT
8 Pages
-
Type ARK · ARK1
8 Pages
-
Type NL
8 Pages
-
Type JZ · JNE · JZ-L · JZD-G
20 Pages
-
Type FSL-B-ZAB
4 Pages
-
Type PKV
7 Pages
-
Type BID
8 Pages
-
Type QLI
8 Pages
-
TVJ-Easy/TVT-Easy
12 Pages
-
LVC
9 Pages
-
RM-O-3-D
7 Pages
-
RM-O-VS-D
7 Pages
-
FK-EU
56 Pages
-
EK-01
14 Pages
-
XSA
12 Pages
-
MSA
12 Pages
-
SCHOOLAIR-V
12 Pages
-
SCHOOLAIR-B
12 Pages
-
FSL-B-SEK
4 Pages
-
DID632
20 Pages
-
DID300B
12 Pages
-
DID312
16 Pages
-
AGW
24 Pages
-
AGS
24 Pages
-
DLQ-1...4-AK
13 Pages
-
DQ/ADQ
9 Pages
-
DLQ/ADLQ
10 Pages
-
DLK-Fb
4 Pages
-
VD
10 Pages
-
QSH · ISH
8 Pages
-
DLQL
12 Pages
-
X-CUBE
16 Pages
-
FV-K90
12 Pages
-
TVR-Ex _ TES/TEF
7 Pages
-
AK-Ex
5 Pages
-
FKRS-EU
28 Pages
-
Multileaf Dampers
8 Pages
-
Star Climate
16 Pages
-
X-GRILLE-Basic
4 Pages
-
X-GRILLE-Basic
3 Pages
-
Jet nozzles TJN
3 Pages
-
ARCHITECTURE NEEDS TO BREATHE
16 Pages
-
SD
10 Pages
-
AIRNAMIC
12 Pages
-
XARTO
12 Pages
-
X-CUBE COMPACT
10 Pages
Archived catalogs
-
Displacement Flow Diffusers
32 Pages
-
Product Summary
7 Pages
-
Quick selection guide
48 Pages
-
Air-water systems Design manual
60 Pages
-
Slot Diffuser
11 Pages
-
Passive Chilled Beams
7 Pages
-
Swirl Diffusers
17 Pages
-
Grilles/Linear Grilles
24 Pages
-
Swirl Diffusers Type FDE
6 Pages
-
Swirl Diffuser Type VDW
20 Pages
-
The art of handling air
80 Pages