Catalog excerpts
T 1.1/1/EN/2 Grilles Linear Grilles for Walls, Floors, Doors, Rectangular and Circular Ducts
Open the catalog to page 1Description 2Aluminium Grilles Nomenclature Quick Selection 12Acoustic Data 3Aluminium Grilles/Linear Grilles 13Aerodynamic Data for Supply Air 4Steel Grilles/Linear Grilles 14Aerodynamic Data for Return Air 5Grilles for Circular and Rectangular Duct Installation 18Technical Data AGS 6Plastic Grilles 19Standard Sizes 7Grilles with Filter 20Fixing Methods Options 7Rear Assemblies ֖ Flow Rate Control Dampers 20Specification Text 8Rear Assemblies Component Adjustment 21Order Details 9Installation and Fixing Details 22 10 > Grilles and linear grilles can be used as air terminal devices for...
Open the catalog to page 2Type KS grilles suitable for supply and extract use. The grillehas an injection moulded border with holes ( For wall installation, the standard ...-A construction in thetypes AT, VAT, AH, SL, TR and TRS grilles are available with the ...A- EF special border with filter pad or, alternatively, with an additional special hit and miss damper, type ...-AS-EF (see page 9).The grille and special frame with filter pad are connected byspring clip fixing. The special frame with filter pad is available with H = 125 mm to H = 525 mm.Spare E-EF filter media is available on request. 4.5 mm) for...
Open the catalog to page 7ASLAT/ VAT AH-0 / AH-15 AF-0 / AF-15 AWT SL TR / TRS TRS-K / TRS-R AH-0 / AH-15 AF-0 / AF-15 SL Grille face only-A -AG > 1) -D Grille face with rear assemblies-DG > 1) -KS/RS/AS > 1) -AS > 1) -K5/R5 > 2) Grille face with filter-A-EF > 2) Grille face with rear assembly and filter-AS-EF > 2) 1) For duct installation with angle border (type AGW DGW) supplied loose! (see page 8)2) Not available with concealed fixing! >
Open the catalog to page 9Installation Dtails Fixing D镩tails Installation Subframe ER The installation subframes are supplied as individual components, tied together with different coloured banding, using the tongue and spigot connection. Brown banding - Types AT, VAT, AH with 23 mm or 20 mm wide front (ER 5) Installation Subframe for Grilles (ER) frame parts Red banding Transparent banding Type SL (ER 12.5/5) All other types (ER 12.5) j 12.5 ^ - (5) If necessary, the preformed builder's cleat can be bent, e. g. for wall installation. For grilles or linear grilles with secret fixing, an installation subframe is...
Open the catalog to page 10Nomenclature Quick Sթlection Nomenclature A Ageo in m2: Geometric outlet area (AGS) heff in m: Effective outlet height (Aeff= heff x U/1000) a in °: Airstream discharge angle P in °: Blade angle in the case of divergent setting A tZ in K: Temperature difference between supply and room air A tL in K: Difference between core and room temperature at distance LS L in mm: Grille nominal length H in mm: Grille nominal height L1 in m: Grille core size (length) H1 in m: Grille core size (height) A pt in Pa: Total pressure drop LWA in dB(A): A-weighted sound power level LWNC NC rating of sound power...
Open the catalog to page 12q duct total pressure drop ap, in pa Pressure drop a pt in Pa ta o o =: 5" = (5"<S a. » 3 S' S 3?s c gi i.a -, (0 m m -h = tu o q-"■ co il co o co o 3 5" E o S m co = Ta ~ 3 ci r- 1 r- o > p Grille face Pattern control blad i x o o o + x ° + x 1.2 ° o + x 1.1 en en + x 1.5 cd cd o o cd m-s <層 m 3 cd s q. c <■ cd cB ct §S)o ® cd °-" o 3 5" 3 o o o o o ii o 3 eu cd o Pressure drop a pt in Pa -----» Pressure drop a pt in Pa 00 cd m- s <q m 3 3" o o o p o o o cd ro ro ll ll b b b ol o ol o ol co 5' o o o o ol o o 3 n> + + + + + i i o -si en co ro o o o ni + + + + + + i 01 co -si -pi ro o (d o _...
Open the catalog to page 13Data given: Type AT-A, with ceiling effectDistance from the grilleL > 2 S =10 mMaximum jet velocity > eff עɈ 0.043 m > L =0.5 m/sTotal volume flow Ç > t =150 l/sTemperature differential betweensupply and room air t > Z =-4 KDiagram 5 (page 15):A > eff =0.041 m > 2 v > eff =3.8 m/sb > 0,2 =1.2 mi=15 t > L / t > Z =0.13 Correction factors for installation without ceiling effect(free stream) t > L =-4 x 0.13 = -0.52 KThe diagram values are valid for B 1.5 m (0.15 x L If the distance to the ceiling is 0.8 m, the diagram values > S )If the spacing between 2 grilles is smaller, multiply à and ∆ t...
Open the catalog to page 14Volume Flow Measurement Correction Factors (where L = const.) The volume flow can be determined by measuring the airvelocity with zero blade divergence using either a pitot tube or a rotating vane anemometer.Pitot tube (Figure 1):Measurements of air velocity should be made between the blades at a number of positions to determine an arithmetic mean value v > Figure1Figure2 109 eff.mean .The volume flow is then calculated as follows:V. > t [l/s]= v > eff.mean [m/s] x A > eff [m > 2 ] x 1000V. > t [m > 3 /h]= v > eff.mean [m/s] x A > eff [m > 2 ] x 3600Rotating Vane Anemometer (Figure 2):The...
Open the catalog to page 16Aerodynamic Data for Supply Air Linear Grilles with Ceiling Effect Air Stream Deflection Effective outlet height H heff in m H heff in m in mm SL AH Օ AF in mm SL AH AF 75 - 0.030 225 0.150 0.115 125 0.075 0.057 325 0.225 0.170 17
Open the catalog to page 17Rear assemblies/volume flow adjustment components To optimise the air distribution, rear assemblies are fitted. These can be adjusted from the grille face without its removal. -D :Set of adjustable rear air pattern control bladeswhich are installed at 90to the front blades. -AG :Opposed blade action flow rate controller with screwdriver adjustment. -DG :as in -D in combination with -AG . -AS :Hit and miss control with air flow straightener forflow volume regulation. Adjustment via two screws and sliding the lower slotted plate. -R5/K5 :Angled hit and miss control with air flow straightener...
Open the catalog to page 21Order Dtails Grilles Aluminium and Steel These codes need not be completed for standard products SL - AG / 1025 x 125 / M1 / 0 / P1 / RAL 9016 Aluminium Grilles (see pages 3 ■ 4) Type ASL AT VAT AH-0 AH-15 AF-0 AF-15 AWT State colour L x H (see page 20) 0 P1 Standard finish E6-C-0 Powder coated to RAL 9006 (GE 30 %)2) other colours to RAL ... (GE 70 %)2) Without installation subframe 0 With installation subframe .. (see page 20) For standard construction (without fixing variant) With fixing variant (see page 20) 0 Steel Grilles (see pages 5) SL TR TRS P1 Standard finish Powder coated to RAL...
Open the catalog to page 22All TROX catalogs and technical brochures
-
Retrofit kits
6 Pages
-
X-GRILLE Cover
18 Pages
-
QUICK SELECTION GUIDE 2019 - 2
804 Pages
-
QUICK SELECTION GUIDE 2019 - 1
530 Pages
-
ATVC-100
8 Pages
-
X-CUBE Compact
12 Pages
-
X-CUBE RUN AROUND COIL SYSTEM
10 Pages
-
Air-water systems
307 Pages
-
ARR
2 Pages
-
WT · WL · EL
8 Pages
-
VMRK
4 Pages
-
VFR
8 Pages
-
Tunnel dampers
20 Pages
-
FKS-EU
20 Pages
-
CAK
6 Pages
-
Type ST · XT
8 Pages
-
Type ARK · ARK1
8 Pages
-
Type NL
8 Pages
-
Type JZ · JNE · JZ-L · JZD-G
20 Pages
-
Type FSL-B-ZAB
4 Pages
-
Type PKV
7 Pages
-
Type BID
8 Pages
-
Type QLI
8 Pages
-
TVJ-Easy/TVT-Easy
12 Pages
-
LVC
9 Pages
-
RM-O-3-D
7 Pages
-
RM-O-VS-D
7 Pages
-
FK-EU
56 Pages
-
EK-01
14 Pages
-
XSA
12 Pages
-
MSA
12 Pages
-
SCHOOLAIR-V
12 Pages
-
SCHOOLAIR-B
12 Pages
-
FSL-B-SEK
4 Pages
-
DID632
20 Pages
-
DID300B
12 Pages
-
DID312
16 Pages
-
AGW
24 Pages
-
AGS
24 Pages
-
DLQ-1...4-AK
13 Pages
-
DQ/ADQ
9 Pages
-
DLQ/ADLQ
10 Pages
-
DLK-Fb
4 Pages
-
VD
10 Pages
-
QSH · ISH
8 Pages
-
DLQL
12 Pages
-
X-CUBE
16 Pages
-
FV-K90
12 Pages
-
TVR-Ex _ TES/TEF
7 Pages
-
AK-Ex
5 Pages
-
JZ-RS
5 Pages
-
FKRS-EU
28 Pages
-
Multileaf Dampers
8 Pages
-
Star Climate
16 Pages
-
X-GRILLE-Basic
4 Pages
-
X-GRILLE-Basic
3 Pages
-
Jet nozzles TJN
3 Pages
-
ARCHITECTURE NEEDS TO BREATHE
16 Pages
-
SD
10 Pages
-
AIRNAMIC
12 Pages
-
XARTO
12 Pages
-
X-CUBE COMPACT
10 Pages
Archived catalogs
-
Displacement Flow Diffusers
32 Pages
-
Product Summary
7 Pages
-
Quick selection guide
48 Pages
-
Air-water systems Design manual
60 Pages
-
Slot Diffuser
11 Pages
-
Passive Chilled Beams
7 Pages
-
Swirl Diffusers
17 Pages
-
Swirl Diffusers Type FDE
6 Pages
-
Swirl Diffuser Type VDW
20 Pages
-
The art of handling air
80 Pages