FKRS-EU

Product catalog summary
Overview: The document outlines the technical specifications and installation guidelines for FKRS-EU fire dampers, which are designed to prevent the spread of fire and smoke through ductwork. These dampers are tested to EN 1366-2 standards and comply with EN 15650.
Specifications:
  • Fire dampers are tested for fire resistance according to EN 1366-2 and classified under EN 13501-3.
  • They can be installed in solid walls, ceiling slabs, lightweight partition walls, and shaft walls.
  • Trigger temperatures are set at 72°C or 95°C, suitable for warm air systems.
  • An accessible release mechanism is included for testing and inspection.
Installation Guidelines:
  • Approved for both horizontal and vertical ducts, with non-critical airflow direction.
  • Installation must comply with national guidelines and standards such as DIN 31051 and EN 13306.
  • Regular testing is required every six months, with potential extension to one year after two successful tests.
  • Fire dampers should be included in the regular cleaning schedule of the ventilation system.
Design Information:
  • Performance class depends on application and installation location.
  • Installation must not impose loads on the damper during a fire.
  • Flexible connectors are recommended for certain applications to accommodate duct expansion and wall deformation.
Construction Features:
  • Circular casing allows easy installation without additional drilling.
  • Spigot connections with lip seal are available for standard and non-standard duct sizes.
  • Available in galvanized or stainless steel with optional powder coating for enhanced corrosion protection.
Accessories:
  • Installation blocks and dry mortarless kits facilitate easy installation without mortar.
  • Wall face frames are available for dry mortarless installation on solid walls.
  • Cover grilles and flexible connectors prevent load imposition on dampers.
Additional Features:
  • Integration with central BMS via TROXNETCOM.
  • Limit switches indicate damper blade positions.
Specifications:
Fire dampers are equipped with fusible links and can have one or two limit switches. The protection level is IP 66, and the contact type is a changeover contact, gold-plated, with a maximum switching current of 0.5 A and voltage of 30 V DC or 250 V AC.
Procedures:
Fire dampers with spring return actuators allow remote control and release via smoke detectors. If the supply voltage fails, the damper closes automatically. The actuator includes two limit switches, and the connecting cables are designed for quick connection to the TROX AS-i bus system. A conversion kit is available for retrofitting actuators.
Standards and Recommendations:
Installation of fire dampers is approved for solid walls and ceiling slabs with specific requirements for material density and thickness. Mortar-based and dry mortarless installations are both approved methods. The installation must ensure a minimum distance from structural elements and between dampers.
Wiring and Connection:
Wiring examples are provided for both OPEN and CLOSED positions. The system uses a standard bus system (AS interface) for integration and control, ensuring compatibility across different manufacturers.
Performance Parameters:
Tables provide quick selection data for sound power levels, differential pressure, and airflow velocity based on nominal sizes. The maximum upstream velocity is specified for different constructions.
Installation Details:
Detailed instructions are provided for mortar-based and dry mortarless installations, including the use of extension pieces and specific requirements for wall and ceiling slab installations. The document outlines the necessary dimensions and materials for effective installation.
1. Installation Methods:
  • Mortar-Based Installation: Requires an installation opening with specific dimensions, using mortar or gypsum mortar to fill perimeter gaps. Suitable for lightweight partition walls with metal support structures.
  • Dry Mortarless Installation: Utilizes square installation blocks or kits (EQ or TQ) for easy installation without mortar. Requires specific opening dimensions and screw fixing to reinforcing sections.
2. Installation Details:
  • Lightweight Partition Walls: Both mortar-based and dry mortarless methods are applicable. Walls must have a metal support structure and cladding on both sides, with a minimum thickness of 100 mm.
  • Fire Walls: Installation can be mortar-based or dry. Walls must comply with EN 13501-2 standards, with a minimum thickness of 115 mm for cladding.
3. Requirements and Recommendations:
  • Minimum distances between fire dampers and structural elements are specified to ensure safety and compliance.
  • Use of extension pieces is recommended for walls exceeding certain thicknesses.
4. Specifications:
  • Fire dampers are available in various nominal sizes, tested for fire resistance according to EN 1366-2.
  • Complies with EN 15650 and EN 13501-3 standards, suitable for both mortar-based and dry installations.
5. Special Features:
  • Integration with central BMS via TROXNETCOM.
  • Low differential pressure due to large free cross-sectional area.
  • Materials include galvanized sheet steel casing and special insulating material for damper blades.
6. Order Details: Provides order codes and examples for different configurations, including options for fusible links and powder-coated casings.
See more

Catalog excerpts

FKRS-EU-1

Fire dampers Type FKRS-EU tested to EN 1366-2 according to Declaration of Performance DoP / FKRS-EU / DE / 2013 / 001

 Open the catalog to page 1
FKRS-EU-2

Contents · Description Description__________________________________ Correct use__________________________________ Construction · Dimensions_______________________ Accessories 1: Installation block_____________________________ Dry mortarless installation kit___________________ Wall face frame______________________________ Accessories 2: Cover grille · Flexible connectors________________ Attachments: Limit switches_______________________________ Spring return actuator_________________________ TROXNETCOM_____________________________ FKRS-EU with fusible link In case of a fire, fire dampers shut...

 Open the catalog to page 2
FKRS-EU-3

Correct use To ensure complete functioning of the fire damper it is essential to read the operating and installation manual and to comply with it. In addition, the national guidelines must be complied with. The general guidelines of DIN 31051 and EN 13306 are also applicable. The functional reliability of fire dampers must be tested at least every six months. If two consecutive tests are successful, the next test can be conducted one year later. In general, it is sufficient to release and re-open the fire damper; for a fire damper with spring return actuator this can be done by remote control....

 Open the catalog to page 3
FKRS-EU-4

Construction · Dimensions Characteristics Construction features – Classified according to EN 13501-3 – For classes of performance see the table on page 3 – Airflow in either direction – Large free cross sectional area, hence low differential pressure – Release temperature 72 °C or 95 °C (for use in warm air ventilation systems) – Approved installation orientation for horizontal ducts from 0° up to 360° – Circular casing suitable for push fitting into cut circular holes without additional drilling and chiseling being required – Spigot connections on both ends, with lip seal, suitable for ventilation...

 Open the catalog to page 4
FKRS-EU-5

Construction · Dimensions The construction variants with stainless steel or powder-coated casing meet even more critical requirements for corrosion protection. They are also available with a coated damper blade. Detailed listing on request. Construction variant 1 Casing Galvanised Powder-coated Stainless steel1 Galvanised Powder-coated Stainless steel1 Not for fire batt installation. Order code Damper blade Standard Standard Standard Coated Coated Coated – Casing in galvanised sheet steel, with powder coating RAL 7001 (1), or in stainless steel 1.4301 (2) – Damper blade made of special insulation...

 Open the catalog to page 5
FKRS-EU-6

Accessories 1 Installation block FKRS-EU fire dampers with installation block or dry mortarless installation kit are required for installation without perimeter mortar infill (dry mortarless installation). Installation block – Circular installation block ER for solid walls and ceiling slabs, the outer diameter of the installation block corresponds to standard core bits – Square installation block EQ for lightweight partition walls with metal support structure and cladding on one side or both sides, as well as for lightweight fire walls Fire damper and installation block are assembled at the factory...

 Open the catalog to page 6
FKRS-EU-7

Dry mortarless installation kit Dry mortarless installation kit – Square dry mortarless installation kit for lightweight partition walls with metal support structure and cladding on both sides, as well as for lightweight fire walls The fire damper and dry mortarless installation kit are assembled at the factory and form a unit. The unit is installed without a mortar-mix by simply inserting it into the prepared installation opening. In case of a fire the foaming seal closes the remaining gap. A plate covers any joints and is used for screw fixing. Square dry mortarless installation kit – Dry mortarless...

 Open the catalog to page 7
FKRS-EU-8

Accessories 1 Wall face frame Wall face frame FKRS-EU fire dampers with wall face frame are required for dry mortarless installation on the face of solid walls. Fire damper and wall face frame are assembled at the factory and form a unit. The unit is installed without a mortar-mix by simply inserting it into the prepared installation opening. The wall face frame is fixed with suitable screws and anchors (with suitability certificate). Instead of anchors, threaded rods can be used (push through installation). Wall face frame – Wall face frame made of calcium silicate FKRS-EU with wall face frame...

 Open the catalog to page 8
FKRS-EU-9

Cover grille · Flexible connectors Flexible connectors Ducting must be installed in such a manner that it does not impose any loads on the fire damper in case of a fire. For information on how to limit such loads please refer to the guideline regarding fire protection requirements on ventilation systems (Lüftungsanlagen-Richtlinie, LüAR). As ducts may expand and walls may become deformed in case of a fire, we recommend for the following applications using flexible connectors when connecting the fire damper to rigid ducts: – in lightweight partition walls – in lightweight shaft walls – when used...

 Open the catalog to page 9
FKRS-EU-10

Attachments Limit switch FKRS-EU with fusible link Order code Standard construction Limit switches with volt-free contacts enable the damper blade position indication. Relays or indicator lights for fire alarm systems can be used up to the maximum switch rating. One limit switch each is required for damper blade positions OPEN and CLOSED. Fire dampers with a fusible link can be supplied with one or two limit switches; the switches can also be fitted later. Standard construction with limit switch for damper blade position CLOSED Standard construction with limit switch for damper blade position...

 Open the catalog to page 10
FKRS-EU-11

Attachments Spring return actuator FKRS-EU with spring return actuator Order code Operation of the fire damper with a spring return actuator allows remote control and/or release by a suitable smoke detector. If the supply voltage fails, or with thermoelectric release, the damper closes (power off to close). Fire dampers with spring return actuator can be functionally checked OPEN/CLOSED/ OPEN. The actuator includes two limit switches. The connecting cables of the BLF24-T-ST TR are fitted with plugs. This ensures quick and easy connection to the TROX AS-i bus system. A conversion kit is available...

 Open the catalog to page 11

All TROX catalogs and technical brochures

  1. Retrofit kits

    6  Pages

  2. X-GRILLE Cover

    18  Pages

  3. ATVC-100

    8  Pages

  4. X-CUBE Compact

    12  Pages

  5. ARR

    2  Pages

  6. VMRK

    4  Pages

  7. VFR

    8  Pages

  8. Tunnel dampers

    20  Pages

  9. FKS-EU

    20  Pages

  10. CAK

    6  Pages

  11. Type ST · XT

    8  Pages

  12. Type NL

    8  Pages

  13. Type PKV

    7  Pages

  14. Type BID

    8  Pages

  15. Type QLI

    8  Pages

  16. LVC

    9  Pages

  17. RM-O-3-D

    7  Pages

  18. RM-O-VS-D

    7  Pages

  19. FK-EU

    56  Pages

  20. EK-01

    14  Pages

  21. XSA

    12  Pages

  22. MSA

    12  Pages

  23. SCHOOLAIR-V

    12  Pages

  24. SCHOOLAIR-B

    12  Pages

  25. FSL-B-SEK

    4  Pages

  26. DID632

    20  Pages

  27. DID300B

    12  Pages

  28. DID312

    16  Pages

  29. AGW

    24  Pages

  30. AGS

    24  Pages

  31. DLQ-1...4-AK

    13  Pages

  32. DQ/ADQ

    9  Pages

  33. DLQ/ADLQ

    10  Pages

  34. DLK-Fb

    4  Pages

  35. VD

    10  Pages

  36. QSH · ISH

    8  Pages

  37. DLQL

    12  Pages

  38. X-CUBE

    16  Pages

  39. FV-K90

    12  Pages

  40. AK-Ex

    5  Pages

  41. JZ-RS

    5  Pages

  42. Star Climate

    16  Pages

  43. SD

    10  Pages

  44. AIRNAMIC

    12  Pages

  45. XARTO

    12  Pages

  46. X-CUBE COMPACT

    10  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.