Displacement Flow Diffusers-1

TROX HESCO Schweiz AG Walderstrasse 125 Postfach 455 CH - 8630 Rüti ZH Tel. +41 (0)55 250 71 11 Fax +41 (0)55 250 73 10 www.troxhesco.ch [email protected] Displacement flow diffusers L-08-1-04e

 Open the catalog to page 1
Displacement Flow Diffusers-2

2 0 1000 2000 3000 4000 5000 ‡ [m³/h] 368 102.2 382 106.1 578 160.5 <15 32 44 20 40 54 Lw [dB(A)] Lw [dB(A)] 0 200 400 600 800 1000 1200 ‡ [l/s] 600×1500×600-1×400 600×2000×600-1×400 700×2000×700-1×500 C1 m³/h C2 l/s <15 32 44 54 65 Lw [dB(A)] 54 Construction TROX HESCO displacement flow diffusers in standard construction are made of galvanised sheet steel. The face plate is perforated with 3 mm holes. The visible areas are painted white (RAL 9010). Other RAL colours are available on request. They are maintenance-free because they do not use filter material. Customised versions are available....

 Open the catalog to page 2
Displacement Flow Diffusers-3

3 T a b B-30 | H-30 B T ½ B ½ B B-30 / H-30 ½ B T B B-30 / H-30 T a b B + 2 T = B + 2 = F1 / F2 øD E E T T C ød D B ½B a T H h ød B a ød T a H 2000 1500 h Äh B ød H h B B T ½ B ød H h B B b T d b a H h B B ød B ½B H h B B ød B ½B H h B ød B B ½B T d b b H h a B B ...-EO/ ...-EO-3/ ...-EO-2L ...-EO-2R Page 19-21 Type QL-WQT-RO-2/ Type QL-WQT-RO-3/ Type QL-WQT-RO-4/ General technical information__________________________ 22 Temperature conditions – Nomenclature ________________ 23 Temperature conditions : Comfort conditioning __________ 24 Temperature conditions : Industrial applications__________...

 Open the catalog to page 3
Displacement Flow Diffusers-9

9 600×600 600 600 500 500 30-40 1) 20 600×600-1×200 600 600 500 500 30-40 1) 26 65 18.1 65 18.1 C1 m³/h C2 l/s øD H E B T C 8mm 50 100 150 200 250 300 350 ‡ [m³/h] 10 20 30 40 50 60 70 80 90 ‡ [l/s] Lw [dB(A)] <15 36 Lw [dB(A)] 600×600 600×600-1×200 <15 25 36 25 Technical Data Quick selection Dimensions Type QL-BE-O/ and B H F1 F2 E Weight Type QL-BE-RO/ [mm] [mm] [mm] [mm] [mm] [kg] Type QL-BE-O/ and Type QL-BE-RO for installation into a false floor Type QL-BE-O/ and Type QL-BE-RO/ Other dimensions on request. 1) Variable, depending on thickness of floor tile Not available in stainless steel....

 Open the catalog to page 9
Displacement Flow Diffusers-17

17 600×1200×350-1×250 600 1200 350 248 50-70 22 600×2000×350-1×315 600 2000 350 313 50-70 28 0 200 400 600 800 1000 1200 1400 1600 1800 ‡ [m³/h] 111 30.9 190 52.8 0 50 100 150 200 250 300 350 400 450 500 ‡ [l/s] <15 33 45 <15 33 45 Lw [dB(A)] Lw [dB(A)] 600×1200×350-1×250 600×2000×350-1×315 C1 m³/h C2 l/s H h B B T ½ B ød 55 55 Technical Data Type QL-WFT-RO/ for installation on a wall surface with trapezoidal face, circular connecting spigot, without base Dimensions Type QL-WFT-RO/ B H T Ød h Weight [mm] [mm] [mm] [mm] [mm] [kg] Type QL-WFT-RO/ Quick selection Other dimensions on request.

 Open the catalog to page 17
Displacement Flow Diffusers-18

18 1200×2000×220-800×170 1200 2000 220 798 168 100 110 55 1200×2000×350-800×300 1200 2000 350 798 298 100 150 66 0 1000 2000 3000 4000 5000 ‡ [m³/h] 347 96.5 516 143.2 16 36 48 <15 30 42 Lw [dB(A)] Lw [dB(A)] 0 200 400 600 800 1000 1200 ‡ [l/s] 1200×2000×220-800×170 1200×2000×350-800×300 C1 m³/h C2 l/s H h B B b T d b a 59 52 Type QL-WFT-E/ for installation on a wall surface with trapezoidal face, rectangular connecting spigot, one way discharge, without base Dimensions Type QL-WFT-E/ B H T b a h d Weight [mm] [mm] [mm] [mm] [mm] [mm] [mm] [kg] Type QL-WFT-E/ Quick selection Technical Data Other...

 Open the catalog to page 18
Displacement Flow Diffusers-19

19 800×2000× 800-1×630 800 2000 628 100 100 1200×2000×1200-1×800 1200 2000 798 100 157 0 1000 2000 3000 4000 5000 6000 7000 8000 ‡ [m³/h] 675 187.4 1063 295.2 800×2000× 800-1×630 1200×2000×1200-1×800 C1 m³/h C2 l/s Lw [dB(A)] 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 ‡ [l/s] <15 31 44 <15 30 42 Lw [dB(A)] H h B B ød B ½B 54 52 Technical Data Dimensions Type QL-WQT-RO-2/ B H Ød h Weight [mm] [mm] [mm] [mm] [kg] Type QL-WQT-RO-2/ Quick selection Type QL-WQT-RO-2/ for installation on a wall surface with trapezoidal face, circular connecting spigot, two way discharge, without base Other...

 Open the catalog to page 19
Displacement Flow Diffusers-20

20 800×2000× 800-1×630 800 2000 628 100 108 1200×2000×1200-1×800 1200 2000 798 100 167 0 2000 4000 6000 8000 10000 12000 14000 ‡ [m³/h] 792 220.1 1241 344.7 800×2000× 800-1×630 1200×2000×1200-1×800 C1 m³/h C2 l/s <15 33 46 Lw [dB(A)] <15 32 44 Lw [dB(A)] 0 500 1000 1500 2000 2500 3000 3500 ‡ [l/s] H h B B ød B ½B 56 54 Type QL-WQT-RO-3/ for installation on a wall surface with trapezoidal face, circular connecting spigot, three way discharge, without base Dimensions Type QL-WQT-RO-3/ B H Ød h Weight [mm] [mm] [mm] [mm] [kg] Type QL-WQT-RO-3/ Quick selection Technical Data Other dimensions on request....

 Open the catalog to page 20
Displacement Flow Diffusers-21

21 800×2000× 800-1×630 800 2000 628 100 116 1200×2000×1200-1×800 1200 2000 798 100 184 0 2000 4000 6000 8000 10000 12000 14000 ‡ [m³/h] 851 236.4 1329 369.0 800×2000× 800-1×630 1200×2000×1200-1×800 C1 m³/h C2 l/s 18 38 51 Lw [dB(A)] Lw [dB(A)] 17 37 50 0 500 1000 1500 2000 2500 3000 3500 ‡ [l/s] H h B ød B B ½B 62 60 Type QL-WQT-RO-4/ for free standing installation with trapezoidal face, circular connecting spigot, four way discharge, without base Technical Data Dimensions Type QL-WQT-RO-4/ B H Ød h Weight [mm] [mm] [mm] [mm] [kg] Type QL-WQT-RO-4/ Quick selection Other dimensions on request.

 Open the catalog to page 21
Displacement Flow Diffusers-22

22 General technical information for the selection of TROX HESCO displacement flow diffusers Displacement flow is different from mixed flow not only in that the discharge point is no longer in or near the ceiling area but also in that the air movement is driven by the thermal convection generated by users of the space, machines, computers etc. Because the outlets for displacement flow are normally in the occupied zone, the discharge velocities are very low compared to mixed flow. 0,1 to 0,2 m/s in comfort conditioning and up to a maximum of 0,5 m/s in industrial applications or situations where...

 Open the catalog to page 22

All TROX catalogs and technical brochures

  1. Retrofit kits

    6  Pages

  2. X-GRILLE Cover

    18  Pages

  3. ATVC-100

    8  Pages

  4. X-CUBE Compact

    12  Pages

  5. ARR

    2  Pages

  6. VMRK

    4  Pages

  7. VFR

    8  Pages

  8. Tunnel dampers

    20  Pages

  9. FKS-EU

    20  Pages

  10. CAK

    6  Pages

  11. Type ST · XT

    8  Pages

  12. Type NL

    8  Pages

  13. Type PKV

    7  Pages

  14. Type BID

    8  Pages

  15. Type QLI

    8  Pages

  16. LVC

    9  Pages

  17. RM-O-3-D

    7  Pages

  18. RM-O-VS-D

    7  Pages

  19. FK-EU

    56  Pages

  20. EK-01

    14  Pages

  21. XSA

    12  Pages

  22. MSA

    12  Pages

  23. SCHOOLAIR-V

    12  Pages

  24. SCHOOLAIR-B

    12  Pages

  25. FSL-B-SEK

    4  Pages

  26. DID632

    20  Pages

  27. DID300B

    12  Pages

  28. DID312

    16  Pages

  29. AGW

    24  Pages

  30. AGS

    24  Pages

  31. DLQ-1...4-AK

    13  Pages

  32. DQ/ADQ

    9  Pages

  33. DLQ/ADLQ

    10  Pages

  34. DLK-Fb

    4  Pages

  35. VD

    10  Pages

  36. QSH · ISH

    8  Pages

  37. DLQL

    12  Pages

  38. X-CUBE

    16  Pages

  39. FV-K90

    12  Pages

  40. AK-Ex

    5  Pages

  41. JZ-RS

    5  Pages

  42. FKRS-EU

    28  Pages

  43. Star Climate

    16  Pages

  44. SD

    10  Pages

  45. AIRNAMIC

    12  Pages

  46. XARTO

    12  Pages

  47. X-CUBE COMPACT

    10  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.