Active Chilled Beams Type DID300B TROX GmbH Heinrich-Trox-Platz D-47504 Neukirchen-Vluyn
Open the catalog to page 1Contents · Description Contents · Description Construction Casing arrangements Dimensions Assembly DID300B-...-V Top entry air connection spigot Nomenclature Performance overview – cooling with 2-pipe and 4-pipe systems Performance overview – heating with 4-pipe systems Aerodynamic data Order details DID300B-...-H Side entry air connection spigot Description TROX Active Chilled Beams type DID300B use a combination of air and water systems. They combine the air flow characteristics of ceiling diffusers with the energy benefits of load dissipation using water (heating/cooling). The primary...
Open the catalog to page 2L1 = Total length (diffuser face) LN = Nominal length (for dimensions of unit see page 5) Construction with supply air spigot Construction with supply and extract air spigot L1 View A - A Construction with top entry supply air spigot View B - B Construction with side extract air spigot 10b only with 4-pipe system View A - A Construction with side entry supply air spigot View B - B Construction with top extract air spigot only with 4-pipe system Supply air top entry connecting spigot Supply air side entry connecting spigot Top of casing (plenum) Discharge nozzles Casing Coil (pipe-Ø 12 mm)...
Open the catalog to page 3Casing arrangements Top entry supply air spigot Side entry supply air spigot Chilled water connection Side extract air spigot Warm water connection Casing arrangement with top entry supply air spigot V-S Casing arrangement with side entry supply air spigot H - SV Casing arrangement with top entry supply and extract air spigot V - L - AR Casing arrangement with side entry supply and extract air spigot H - LV - ARV
Open the catalog to page 4For construction and casing arrangements see pages 3 and 4 Arrangement of the top active plenum Extends over total length (standard) LN Arrangement of the top active plenum (plenum shorter than L1) Arrangement of the top active plenum (plenum shorter than L1) Arrangement of the top active plenum (plenum shorter than L1) Arrangement of the top active plenum (plenum shorter than L1) Arrangement of the top active plenum (plenum shorter than L1) Arrangement of the top active plenum (plenum shorter than L1) All dimensions in mm with normal tolerances for sheet construction!
Open the catalog to page 5Assembly Assembly The two long sides of the DID300B are each provided with two suspension holes or for L1 = 1500 4 holes are provided on each side. The assembly is installed on site using wire or metal hangers which must have the Building Authority certificate of approval. When the DID300B has been installed, 4 locking devices can be loosened with a screw driver (detail X) and the whole induction grille can be lowered down lengthways. The induction grille is supported by two safety cables. The coil is accessible when the induction grille is removed. The coil connections are on the outside...
Open the catalog to page 6Installation The DID300B unit is fitted with a border extrusion which is suitable for the usual range of ceiling constructions. This ensures the best possible ceiling design. Installation in T-bar ceilings or closed ceilings Installation into grid ceilings Weight relative to the stability of the construction must be taken off the ceiling. Suspension holes are provided for this. The same also applies to preventing the units themselves from sagging. The DID300B can be installed on site at the ends using the support angles which are available as an accessory. The support angles are supplied...
Open the catalog to page 7Side entry connection LN tWRK tWVH tWRH tVWK Temp. diff. between room air tR and core tL at distance L = X + H1 Temp. diff. between room air tR and core tH1 at distance L = A/2 + H1 Temp. diff. between room air and primary air Temp. diff. between room air and supply air into space Water temperature difference Temp. diff. between room air and water flow temperature Primary air pressure drop Water pressure drop Room temperature Water flow temperature – cooling Water return temperature – cooling Water flow temperature – heating Water return temperature – heating Water cooling capacity Water...
Open the catalog to page 8Performance overview – cooling with 2-pipe and 4-pipe system Reference values tWVK = tPr = 16°C ‡WK = 110 l/h (LN 900 up to 1800) ‡WK = 200 l/h (LN 2100 up to 3000) ∆tPr = tPr – tR = –10 K ∆tRWV = tWVK – tR = –10 K LN Correction factors LWA, entry from top side dB(A) dB(A)
Open the catalog to page 9Performance overview – heating with 4-pipe system tR = tPr = 22°C (isothermal) ‡WH = 50 l/h (LN 900 up to 1800) ‡WH = 110 l/h (LN 2100 up to 3000) ∆tRWV = tWVH – tR = 28 K Type of nozzles Reference values LWA, entry from top side dB(A) dB(A)
Open the catalog to page 10Aerodynamic data Correction factors for diagram values depending on length of unit L N LN in mm - vL, vH1, Xkrit. from diagram
Open the catalog to page 11Order details Specification text Support angles and flexible hoses are available as accessories for the DID300B unit. The active chilled beam type DID300B is suitable for dealing with high internal heat loads using a combination of air and water. It consists of the top plenum which serves as primary air duct and a diaphragm plate with nozzles in two longitudinal rows (different nozzle sizes are available). A coil is fitted underneath the primary air plenum and diaphragm plate. The induction grille below the coil is a perforated plate. The coil can be used either for heating or cooling...
Open the catalog to page 12All TROX catalogs and technical brochures
-
Retrofit kits
6 Pages
-
X-GRILLE Cover
18 Pages
-
QUICK SELECTION GUIDE 2019 - 2
804 Pages
-
QUICK SELECTION GUIDE 2019 - 1
530 Pages
-
ATVC-100
8 Pages
-
X-CUBE Compact
12 Pages
-
X-CUBE RUN AROUND COIL SYSTEM
10 Pages
-
Air-water systems
307 Pages
-
ARR
2 Pages
-
WT · WL · EL
8 Pages
-
VMRK
4 Pages
-
VFR
8 Pages
-
Tunnel dampers
20 Pages
-
FKS-EU
20 Pages
-
CAK
6 Pages
-
Type ST · XT
8 Pages
-
Type ARK · ARK1
8 Pages
-
Type NL
8 Pages
-
Type JZ · JNE · JZ-L · JZD-G
20 Pages
-
Type FSL-B-ZAB
4 Pages
-
Type PKV
7 Pages
-
Type BID
8 Pages
-
Type QLI
8 Pages
-
TVJ-Easy/TVT-Easy
12 Pages
-
LVC
9 Pages
-
RM-O-3-D
7 Pages
-
RM-O-VS-D
7 Pages
-
FK-EU
56 Pages
-
EK-01
14 Pages
-
XSA
12 Pages
-
MSA
12 Pages
-
SCHOOLAIR-V
12 Pages
-
SCHOOLAIR-B
12 Pages
-
FSL-B-SEK
4 Pages
-
DID632
20 Pages
-
DID312
16 Pages
-
AGW
24 Pages
-
AGS
24 Pages
-
DLQ-1...4-AK
13 Pages
-
DQ/ADQ
9 Pages
-
DLQ/ADLQ
10 Pages
-
DLK-Fb
4 Pages
-
VD
10 Pages
-
QSH · ISH
8 Pages
-
DLQL
12 Pages
-
X-CUBE
16 Pages
-
FV-K90
12 Pages
-
TVR-Ex _ TES/TEF
7 Pages
-
AK-Ex
5 Pages
-
JZ-RS
5 Pages
-
FKRS-EU
28 Pages
-
Multileaf Dampers
8 Pages
-
Star Climate
16 Pages
-
X-GRILLE-Basic
4 Pages
-
X-GRILLE-Basic
3 Pages
-
Jet nozzles TJN
3 Pages
-
ARCHITECTURE NEEDS TO BREATHE
16 Pages
-
SD
10 Pages
-
AIRNAMIC
12 Pages
-
XARTO
12 Pages
-
X-CUBE COMPACT
10 Pages
Archived catalogs
-
Displacement Flow Diffusers
32 Pages
-
Product Summary
7 Pages
-
Quick selection guide
48 Pages
-
Air-water systems Design manual
60 Pages
-
Slot Diffuser
11 Pages
-
Passive Chilled Beams
7 Pages
-
Swirl Diffusers
17 Pages
-
Grilles/Linear Grilles
24 Pages
-
Swirl Diffusers Type FDE
6 Pages
-
Swirl Diffuser Type VDW
20 Pages
-
The art of handling air
80 Pages