Catalog excerpts

DID300B-1

Active Chilled Beams Type DID300B TROX GmbH Heinrich-Trox-Platz D-47504 Neukirchen-Vluyn

 Open the catalog to page 1
DID300B-2

Contents · Description Contents · Description Construction Casing arrangements Dimensions Assembly DID300B-...-V Top entry air connection spigot Nomenclature Performance overview – cooling with 2-pipe and 4-pipe systems Performance overview – heating with 4-pipe systems Aerodynamic data Order details DID300B-...-H Side entry air connection spigot Description TROX Active Chilled Beams type DID300B use a combination of air and water systems. They combine the air flow characteristics of ceiling diffusers with the energy benefits of load dissipation using water (heating/cooling). The primary air...

 Open the catalog to page 2
DID300B-3

L1 = Total length (diffuser face) LN = Nominal length (for dimensions of unit see page 5) Construction with supply air spigot Construction with supply and extract air spigot L1 View A - A Construction with top entry supply air spigot View B - B Construction with side extract air spigot 10b only with 4-pipe system View A - A Construction with side entry supply air spigot View B - B Construction with top extract air spigot only with 4-pipe system Supply air top entry connecting spigot Supply air side entry connecting spigot Top of casing (plenum) Discharge nozzles Casing Coil (pipe-Ø 12 mm) Perforated...

 Open the catalog to page 3
DID300B-4

Casing arrangements Top entry supply air spigot Side entry supply air spigot Chilled water connection Side extract air spigot Warm water connection Casing arrangement with top entry supply air spigot V-S Casing arrangement with side entry supply air spigot H - SV Casing arrangement with top entry supply and extract air spigot V - L - AR Casing arrangement with side entry supply and extract air spigot H - LV - ARV

 Open the catalog to page 4
DID300B-5

For construction and casing arrangements see pages 3 and 4 Arrangement of the top active plenum Extends over total length (standard) LN Arrangement of the top active plenum (plenum shorter than L1) Arrangement of the top active plenum (plenum shorter than L1) Arrangement of the top active plenum (plenum shorter than L1) Arrangement of the top active plenum (plenum shorter than L1) Arrangement of the top active plenum (plenum shorter than L1) Arrangement of the top active plenum (plenum shorter than L1) All dimensions in mm with normal tolerances for sheet construction!

 Open the catalog to page 5
DID300B-6

Assembly Assembly The two long sides of the DID300B are each provided with two suspension holes or for L1 = 1500 4 holes are provided on each side. The assembly is installed on site using wire or metal hangers which must have the Building Authority certificate of approval. When the DID300B has been installed, 4 locking devices can be loosened with a screw driver (detail X) and the whole induction grille can be lowered down lengthways. The induction grille is supported by two safety cables. The coil is accessible when the induction grille is removed. The coil connections are on the outside of...

 Open the catalog to page 6
DID300B-7

Installation The DID300B unit is fitted with a border extrusion which is suitable for the usual range of ceiling constructions. This ensures the best possible ceiling design. Installation in T-bar ceilings or closed ceilings Installation into grid ceilings Weight relative to the stability of the construction must be taken off the ceiling. Suspension holes are provided for this. The same also applies to preventing the units themselves from sagging. The DID300B can be installed on site at the ends using the support angles which are available as an accessory. The support angles are supplied loose...

 Open the catalog to page 7
DID300B-8

Side entry connection LN tWRK tWVH tWRH tVWK Temp. diff. between room air tR and core tL at distance L = X + H1 Temp. diff. between room air tR and core tH1 at distance L = A/2 + H1 Temp. diff. between room air and primary air Temp. diff. between room air and supply air into space Water temperature difference Temp. diff. between room air and water flow temperature Primary air pressure drop Water pressure drop Room temperature Water flow temperature – cooling Water return temperature – cooling Water flow temperature – heating Water return temperature – heating Water cooling capacity Water heating...

 Open the catalog to page 8
DID300B-9

Performance overview – cooling with 2-pipe and 4-pipe system Reference values tWVK = tPr = 16°C ‡WK = 110 l/h (LN 900 up to 1800) ‡WK = 200 l/h (LN 2100 up to 3000) ∆tPr = tPr – tR = –10 K ∆tRWV = tWVK – tR = –10 K LN Correction factors LWA, entry from top side dB(A) dB(A)

 Open the catalog to page 9
DID300B-10

Performance overview – heating with 4-pipe system tR = tPr = 22°C (isothermal) ‡WH = 50 l/h (LN 900 up to 1800) ‡WH = 110 l/h (LN 2100 up to 3000) ∆tRWV = tWVH – tR = 28 K Type of nozzles Reference values LWA, entry from top side dB(A) dB(A)

 Open the catalog to page 10
DID300B-11

Aerodynamic data Correction factors for diagram values depending on length of unit L N LN in mm - vL, vH1, Xkrit. from diagram

 Open the catalog to page 11
DID300B-12

Order details Specification text Support angles and flexible hoses are available as accessories for the DID300B unit. The active chilled beam type DID300B is suitable for dealing with high internal heat loads using a combination of air and water. It consists of the top plenum which serves as primary air duct and a diaphragm plate with nozzles in two longitudinal rows (different nozzle sizes are available). A coil is fitted underneath the primary air plenum and diaphragm plate. The induction grille below the coil is a perforated plate. The coil can be used either for heating or cooling (2-pipe...

 Open the catalog to page 12

All TROX catalogs and technical brochures

  1. Retrofit kits

    6  Pages

  2. X-GRILLE Cover

    18  Pages

  3. ATVC-100

    8  Pages

  4. X-CUBE Compact

    12  Pages

  5. ARR

    2  Pages

  6. VMRK

    4  Pages

  7. VFR

    8  Pages

  8. Tunnel dampers

    20  Pages

  9. FKS-EU

    20  Pages

  10. CAK

    6  Pages

  11. Type ST · XT

    8  Pages

  12. Type NL

    8  Pages

  13. Type PKV

    7  Pages

  14. Type BID

    8  Pages

  15. Type QLI

    8  Pages

  16. LVC

    9  Pages

  17. RM-O-3-D

    7  Pages

  18. RM-O-VS-D

    7  Pages

  19. FK-EU

    56  Pages

  20. EK-01

    14  Pages

  21. XSA

    12  Pages

  22. MSA

    12  Pages

  23. SCHOOLAIR-V

    12  Pages

  24. SCHOOLAIR-B

    12  Pages

  25. FSL-B-SEK

    4  Pages

  26. DID632

    20  Pages

  27. DID312

    16  Pages

  28. AGW

    24  Pages

  29. AGS

    24  Pages

  30. DLQ-1...4-AK

    13  Pages

  31. DQ/ADQ

    9  Pages

  32. DLQ/ADLQ

    10  Pages

  33. DLK-Fb

    4  Pages

  34. VD

    10  Pages

  35. QSH · ISH

    8  Pages

  36. DLQL

    12  Pages

  37. X-CUBE

    16  Pages

  38. FV-K90

    12  Pages

  39. AK-Ex

    5  Pages

  40. JZ-RS

    5  Pages

  41. FKRS-EU

    28  Pages

  42. Star Climate

    16  Pages

  43. SD

    10  Pages

  44. AIRNAMIC

    12  Pages

  45. XARTO

    12  Pages

  46. X-CUBE COMPACT

    10  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.