Catalog excerpts
2/16/EN/7 Ceiling Diffuser Type ADLR with circular face Type ADLR-Q with square face
Open the catalog to page 1Description 2Quick Selection 6Nomenclature 3Determination of volume flow rate 7Acoustic Data 3Construction Dimensions 8Aerodynamic Data 4Installation Assembly Material 11Order Information 5Spectral Data 14 ADLRADLR-Q > Diffusers Type ADLR and ADLQ are recommended for flushinstallation in ceilings. In this way a coander effectђ with a radial discharge is guaranteed. Typical supply air volume flows for each size are given in the tables and diagrams. Flush mounting is not absolutely necessary for extract air applications.Typical supply air temperature differentials lie within the range of...
Open the catalog to page 2eff In the quick-selection table below the maximum supply air is setat The effective discharge velocity v > eff is measured using a pitottube, Measurements should be taken evenly and distributed over the diffuser face, the average taken then the flow rate can be calculated from the equation below. ׇ > max , such that a sound power level L > WA max of 40 dB(A) is notexceeded. At the minimum volume flow given, the discharge velocity will not fall below v > eff of 2 m/s. This ensures that the CoandaeffectӔ necessary for a ceiling installation will be achieved.In commissioning the volume flows...
Open the catalog to page 3All constructions and sizes are designed for installation in falsesuspended ceilings. If plenum boxes are used the unit is suspended on wires or slotted strip using the drillings provided, or on straps from the slab. The diffuser face is fixed by the central screw and the subframe provided. A snap-on cap is provided to cover the screw head. If a vertical rigid duct is provided on site the diffuser can be fixed by means of a cross bridge and central screw or directly to the neck of the diffuser, e.g. by self tapping screws. For these types of fixings the ...-AR mounting ring can be used.The...
Open the catalog to page 5Acoustic Data Example Data given: Type ADLR; size 2 Volume flow per diffuser V = 80 l/s octave centre frequency in hz L in dB(A) 63 125 250 500 1000 2000 4000 8000 25 25 25 25 25 25 25 25 A L in dB + 15 + 4 + 4 - 2 - 9 - 14 - 19 - 25 inLdWB 40 29 29 23 16 11 6 0 Required: Octave sound power level of air regenerated noise LW Diagram 4: Lwa = 25 dB(A) A pt = 17 Pa Sound power level and Pressure drop Effective jet velocity veff: V 80 = 5.1 m/s veff Aeff- 1000 0.0157 1000 1 Sound power level and pressure drop Type ADLR-ZH Օ ADLR-Q-ZH Size 1 2 3 4 5 6 correction to diagram 1: air flow control...
Open the catalog to page 8in Pa t in Pa p t p Pressure drop Pressure drop > in Pa t in Pa p t p Pressure drop Pressure drop >
Open the catalog to page 9Size Size in Pa t in Pa p t p Pressure drop Pressure drop
Open the catalog to page 10Diagram 10:Temperature quotientBetween the diffusers at 1.70 m height above the floor, withL = A/2 + H t > 1 = 2.0/2 + 1.30 = 2.30 mthe remaining supply air temperature differential is > H1 = 0.16 m/s.At 1.70 m above the floor, at the distance to the wallL = X + H > L = 0.08 x (8) = ֖ 0.64 KAt 1.70 m height above the floor, at the distance to the wallL = X + H > 1 = 1.5 + 1.3 = 2.80 mthe air velocity v- t > 1 = 1.5 + 1.3 = 2.80 mthe remaining temperature differential is > L = 0.14 m/s.At the other distance to the wallL = X + H > L = 0.065 x (8) = ֖ 0.52 KAt L = X + H t > 1 = 2.0 + 1.3 =...
Open the catalog to page 11Aerodynamic Data Result: On the basis of the calculations above, both the acoustic and air distribution requirements can be met, the use of 2 x ADLR-C size 2 installed as in diagram below is recommended. H = 3.0 For a square arrangement of say 4 diffusers please multiply the air velocities from the diagrams by 1.4. 2.0 5.0 1.5 - Dimensions in m 12
Open the catalog to page 12Order Information Spcification Text Ceiling diffusers type ADLR (circular construction), type ADLR-Q (square construction) for flush installation in cei-lings to provide a radial horizontal discharge for supply air application. The diffuser face comprises concentrically arranged circular rings and a circular or square border with peripheral sealing strip centre cone. The diffuser face can be supplied with a rear connecting ring or flow rate control in the form of a butterfly damper adjustable from the diffuser face. Plenum box with special internal air control elements and side or top entry...
Open the catalog to page 14All TROX catalogs and technical brochures
-
Retrofit kits
6 Pages
-
X-GRILLE Cover
18 Pages
-
QUICK SELECTION GUIDE 2019 - 2
804 Pages
-
QUICK SELECTION GUIDE 2019 - 1
530 Pages
-
ATVC-100
8 Pages
-
X-CUBE Compact
12 Pages
-
X-CUBE RUN AROUND COIL SYSTEM
10 Pages
-
Air-water systems
307 Pages
-
ARR
2 Pages
-
WT · WL · EL
8 Pages
-
VMRK
4 Pages
-
VFR
8 Pages
-
Tunnel dampers
20 Pages
-
FKS-EU
20 Pages
-
CAK
6 Pages
-
Type ST · XT
8 Pages
-
Type ARK · ARK1
8 Pages
-
Type NL
8 Pages
-
Type JZ · JNE · JZ-L · JZD-G
20 Pages
-
Type FSL-B-ZAB
4 Pages
-
Type PKV
7 Pages
-
Type BID
8 Pages
-
Type QLI
8 Pages
-
TVJ-Easy/TVT-Easy
12 Pages
-
LVC
9 Pages
-
RM-O-3-D
7 Pages
-
RM-O-VS-D
7 Pages
-
FK-EU
56 Pages
-
EK-01
14 Pages
-
XSA
12 Pages
-
MSA
12 Pages
-
SCHOOLAIR-V
12 Pages
-
SCHOOLAIR-B
12 Pages
-
FSL-B-SEK
4 Pages
-
DID632
20 Pages
-
DID300B
12 Pages
-
DID312
16 Pages
-
AGW
24 Pages
-
AGS
24 Pages
-
DLQ-1...4-AK
13 Pages
-
DQ/ADQ
9 Pages
-
DLQ/ADLQ
10 Pages
-
DLK-Fb
4 Pages
-
VD
10 Pages
-
QSH · ISH
8 Pages
-
DLQL
12 Pages
-
X-CUBE
16 Pages
-
FV-K90
12 Pages
-
TVR-Ex _ TES/TEF
7 Pages
-
AK-Ex
5 Pages
-
JZ-RS
5 Pages
-
FKRS-EU
28 Pages
-
Multileaf Dampers
8 Pages
-
Star Climate
16 Pages
-
X-GRILLE-Basic
4 Pages
-
X-GRILLE-Basic
3 Pages
-
Jet nozzles TJN
3 Pages
-
ARCHITECTURE NEEDS TO BREATHE
16 Pages
-
SD
10 Pages
-
AIRNAMIC
12 Pages
-
XARTO
12 Pages
-
X-CUBE COMPACT
10 Pages
Archived catalogs
-
Displacement Flow Diffusers
32 Pages
-
Product Summary
7 Pages
-
Quick selection guide
48 Pages
-
Air-water systems Design manual
60 Pages
-
Slot Diffuser
11 Pages
-
Passive Chilled Beams
7 Pages
-
Swirl Diffusers
17 Pages
-
Grilles/Linear Grilles
24 Pages
-
Swirl Diffusers Type FDE
6 Pages
-
Swirl Diffuser Type VDW
20 Pages
-
The art of handling air
80 Pages