Ceiling Diffuser Type ADLR/ADLR-Q-1

2/16/EN/7 Ceiling Diffuser Type ADLR with circular face Type ADLR-Q with square face

 Open the catalog to page 1
Ceiling Diffuser Type ADLR/ADLR-Q-2

Description 2Quick Selection 6Nomenclature 3Determination of volume flow rate 7Acoustic Data 3Construction ׷ Dimensions 8Aerodynamic Data 4Installation Assembly ׷ Material 11Order Information 5Spectral Data 14 ADLRADLR-Q > Diffusers Type ADLR and ADLQ are recommended for flushinstallation in ceilings. In this way a coander effectђ with a radial discharge is guaranteed. Typical supply air volume flows for each size are given in the tables and diagrams. Flush mounting is not absolutely necessary for extract air applications.Typical supply air temperature differentials lie within the range of +10K...

 Open the catalog to page 2
Ceiling Diffuser Type ADLR/ADLR-Q-3

eff In the quick-selection table below the maximum supply air is setat The effective discharge velocity v > eff is measured using a pitottube, Measurements should be taken evenly and distributed over the diffuser face, the average taken then the flow rate can be calculated from the equation below. ׇ > max , such that a sound power level L > WA max of 40 dB(A) is notexceeded. At the minimum volume flow given, the discharge velocity will not fall below v > eff of 2 m/s. This ensures that the CoandaeffectӔ necessary for a ceiling installation will be achieved.In commissioning the volume flows per...

 Open the catalog to page 3
Ceiling Diffuser Type ADLR/ADLR-Q-5

All constructions and sizes are designed for installation in falsesuspended ceilings. If plenum boxes are used the unit is suspended on wires or slotted strip using the drillings provided, or on straps from the slab. The diffuser face is fixed by the central screw and the subframe provided. A snap-on cap is provided to cover the screw head. If a vertical rigid duct is provided on site the diffuser can be fixed by means of a cross bridge and central screw or directly to the neck of the diffuser, e.g. by self tapping screws. For these types of fixings the ...-AR mounting ring can be used.The following...

 Open the catalog to page 5
Ceiling Diffuser Type ADLR/ADLR-Q-8

Acoustic Data Example Data given: Type ADLR; size 2 Volume flow per diffuser V = 80 l/s octave centre frequency in hz L in dB(A) 63 125 250 500 1000 2000 4000 8000 25 25 25 25 25 25 25 25 A L in dB + 15 + 4 + 4 - 2 - 9 - 14 - 19 - 25 inLdWB 40 29 29 23 16 11 6 0 Required: Octave sound power level of air regenerated noise LW Diagram 4: Lwa = 25 dB(A) A pt = 17 Pa Sound power level and Pressure drop Effective jet velocity veff: V 80 = 5.1 m/s veff Aeff- 1000 0.0157 1000 1 Sound power level and pressure drop Type ADLR-ZH Օ ADLR-Q-ZH Size 1 2 3 4 5 6 correction to diagram 1: air flow control damper...

 Open the catalog to page 8
Ceiling Diffuser Type ADLR/ADLR-Q-9

in Pa t in Pa p t p Pressure drop Pressure drop > in Pa t in Pa p t p Pressure drop Pressure drop >

 Open the catalog to page 9
Ceiling Diffuser Type ADLR/ADLR-Q-10

Size Size in Pa t in Pa p t p Pressure drop Pressure drop

 Open the catalog to page 10
Ceiling Diffuser Type ADLR/ADLR-Q-11

Diagram 10:Temperature quotientBetween the diffusers at 1.70 m height above the floor, withL = A/2 + H t > 1 = 2.0/2 + 1.30 = 2.30 mthe remaining supply air temperature differential is > H1 = 0.16 m/s.At 1.70 m above the floor, at the distance to the wallL = X + H > L = 0.08 x (8) = ֖ 0.64 KAt 1.70 m height above the floor, at the distance to the wallL = X + H > 1 = 1.5 + 1.3 = 2.80 mthe air velocity v- t > 1 = 1.5 + 1.3 = 2.80 mthe remaining temperature differential is > L = 0.14 m/s.At the other distance to the wallL = X + H > L = 0.065 x (8) = ֖ 0.52 KAt L = X + H t > 1 = 2.0 + 1.3 = 3.30...

 Open the catalog to page 11
Ceiling Diffuser Type ADLR/ADLR-Q-12

Aerodynamic Data Result: On the basis of the calculations above, both the acoustic and air distribution requirements can be met, the use of 2 x ADLR-C size 2 installed as in diagram below is recommended. H = 3.0 For a square arrangement of say 4 diffusers please multiply the air velocities from the diagrams by 1.4. 2.0 5.0 1.5 - Dimensions in m 12

 Open the catalog to page 12
Ceiling Diffuser Type ADLR/ADLR-Q-14

Order Information Spcification Text Ceiling diffusers type ADLR (circular construction), type ADLR-Q (square construction) for flush installation in cei-lings to provide a radial horizontal discharge for supply air application. The diffuser face comprises concentrically arranged circular rings and a circular or square border with peripheral sealing strip centre cone. The diffuser face can be supplied with a rear connecting ring or flow rate control in the form of a butterfly damper adjustable from the diffuser face. Plenum box with special internal air control elements and side or top entry circular...

 Open the catalog to page 14

All TROX catalogs and technical brochures

  1. Retrofit kits

    6  Pages

  2. X-GRILLE Cover

    18  Pages

  3. ATVC-100

    8  Pages

  4. X-CUBE Compact

    12  Pages

  5. ARR

    2  Pages

  6. VMRK

    4  Pages

  7. VFR

    8  Pages

  8. Tunnel dampers

    20  Pages

  9. FKS-EU

    20  Pages

  10. CAK

    6  Pages

  11. Type ST · XT

    8  Pages

  12. Type NL

    8  Pages

  13. Type PKV

    7  Pages

  14. Type BID

    8  Pages

  15. Type QLI

    8  Pages

  16. LVC

    9  Pages

  17. RM-O-3-D

    7  Pages

  18. RM-O-VS-D

    7  Pages

  19. FK-EU

    56  Pages

  20. EK-01

    14  Pages

  21. XSA

    12  Pages

  22. MSA

    12  Pages

  23. SCHOOLAIR-V

    12  Pages

  24. SCHOOLAIR-B

    12  Pages

  25. FSL-B-SEK

    4  Pages

  26. DID632

    20  Pages

  27. DID300B

    12  Pages

  28. DID312

    16  Pages

  29. AGW

    24  Pages

  30. AGS

    24  Pages

  31. DLQ-1...4-AK

    13  Pages

  32. DQ/ADQ

    9  Pages

  33. DLQ/ADLQ

    10  Pages

  34. DLK-Fb

    4  Pages

  35. VD

    10  Pages

  36. QSH · ISH

    8  Pages

  37. DLQL

    12  Pages

  38. X-CUBE

    16  Pages

  39. FV-K90

    12  Pages

  40. AK-Ex

    5  Pages

  41. JZ-RS

    5  Pages

  42. FKRS-EU

    28  Pages

  43. Star Climate

    16  Pages

  44. SD

    10  Pages

  45. AIRNAMIC

    12  Pages

  46. XARTO

    12  Pages

  47. X-CUBE COMPACT

    10  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.