Gebrüder Trox GmbH Product Information Ex Shut-Off Damper Heinrich Trox Platz 47504 Neukirchen-Vluyn Phone +49(0)2845-202-0 Fax +49(0)2845-202-265 http://www.trox.de e-mail: trox@trox.de
Open the catalog to page 1Gebrüder Trox GmbH Product Information Ex Shut-Off Damper Heinrich Trox Platz 47504 Neukirchen-Vluyn Phone +49(0)2845-202-0 Fax +49(0)2845-202-265 http://www.trox.de e-mail: trox@trox.de Shut-off damper With it’s plastic seal, the AK-Ex shut-off damper shuts off volume flow airtight in accordance with DIN/EN 1751, Class 4 and Class 3. The shut-off damper is supplied only with an electrical actuator. The actuator is also available as a spring return actuator (T0F) or equipped with limit switches. The AK-Ex shut-off damper including, the Ex actuator, is used for shutting off volume flow in...
Open the catalog to page 2Gebriider Trox GmbH Heinrich Trox Platz e-mail: trox@trox.de Product Information Design features: - Designed to be used as a volume flow shut-off element in potentially explosive atmosphere of zone 1 and - Airtight in compliance with DIN EN - Adjustment only via electrical actuator (also available as spring return actuator or with limit switches) - Maximum duct pressure 1500 Pa - Maintenance-free control damper mechanism of shut-off damper - Please refer to technical data Available dimensions - Suitable for air ducts conforming to with inlet bead for sealing system (sealing system included...
Open the catalog to page 3Gebruder Trox GmbH Heinrich Trox Platz e-mail: trox@trox.de Product Information Continuous control or 3-pos with spring return Self adjustment: To adjust the signal input/output to the Angle of rotaton of the damper/vah/e the button T must be pushed for minimum 3 sec. YmA YVDC IvDCJmA UmA UVDC Selection of running time for spring return: Standaid wiring - spring return in -10 5ek Additinal wiring terminal 5 - spring return in - 3 5ek -a closed, On (Off] - in ace. to lefNright mounting ot the actuator - b closed, Off [On) - in act to left/right mounting ct the actuator connection box. The...
Open the catalog to page 4Gebrüder Trox GmbH Product Information Ex Shut-Off Damper Heinrich Trox Platz 47504 Neukirchen-Vluyn Phone +49(0)2845-202-0 Fax +49(0)2845-202-265 http://www.trox.de e-mail: trox@trox.de Specification text Explosion-protected shut-off damper (AK-Ex) Circular shut-off damper with protective housing used for shutting off volume flows in ventilation and air conditioning systems. Consisting of galvanised sheet steel housing as well as tube and damper blade made from A2 stainless steel. Shut-off damper designed in compliance with ATEX requirements and ATEX certified. Includes factory-fitted Ex...
Open the catalog to page 5All TROX catalogs and technical brochures
-
Retrofit kits
6 Pages
-
X-GRILLE Cover
18 Pages
-
QUICK SELECTION GUIDE 2019 - 2
804 Pages
-
QUICK SELECTION GUIDE 2019 - 1
530 Pages
-
ATVC-100
8 Pages
-
X-CUBE Compact
12 Pages
-
X-CUBE RUN AROUND COIL SYSTEM
10 Pages
-
Air-water systems
307 Pages
-
ARR
2 Pages
-
WT · WL · EL
8 Pages
-
VMRK
4 Pages
-
VFR
8 Pages
-
Tunnel dampers
20 Pages
-
FKS-EU
20 Pages
-
CAK
6 Pages
-
Type ST · XT
8 Pages
-
Type ARK · ARK1
8 Pages
-
Type NL
8 Pages
-
Type JZ · JNE · JZ-L · JZD-G
20 Pages
-
Type FSL-B-ZAB
4 Pages
-
Type PKV
7 Pages
-
Type BID
8 Pages
-
Type QLI
8 Pages
-
TVJ-Easy/TVT-Easy
12 Pages
-
LVC
9 Pages
-
RM-O-3-D
7 Pages
-
RM-O-VS-D
7 Pages
-
FK-EU
56 Pages
-
EK-01
14 Pages
-
XSA
12 Pages
-
MSA
12 Pages
-
SCHOOLAIR-V
12 Pages
-
SCHOOLAIR-B
12 Pages
-
FSL-B-SEK
4 Pages
-
DID632
20 Pages
-
DID300B
12 Pages
-
DID312
16 Pages
-
AGW
24 Pages
-
AGS
24 Pages
-
DLQ-1...4-AK
13 Pages
-
DQ/ADQ
9 Pages
-
DLQ/ADLQ
10 Pages
-
DLK-Fb
4 Pages
-
VD
10 Pages
-
QSH · ISH
8 Pages
-
DLQL
12 Pages
-
X-CUBE
16 Pages
-
FV-K90
12 Pages
-
TVR-Ex _ TES/TEF
7 Pages
-
JZ-RS
5 Pages
-
FKRS-EU
28 Pages
-
Multileaf Dampers
8 Pages
-
Star Climate
16 Pages
-
X-GRILLE-Basic
4 Pages
-
X-GRILLE-Basic
3 Pages
-
Jet nozzles TJN
3 Pages
-
ARCHITECTURE NEEDS TO BREATHE
16 Pages
-
SD
10 Pages
-
AIRNAMIC
12 Pages
-
XARTO
12 Pages
-
X-CUBE COMPACT
10 Pages
Archived catalogs
-
Displacement Flow Diffusers
32 Pages
-
Product Summary
7 Pages
-
Quick selection guide
48 Pages
-
Air-water systems Design manual
60 Pages
-
Slot Diffuser
11 Pages
-
Passive Chilled Beams
7 Pages
-
Swirl Diffusers
17 Pages
-
Grilles/Linear Grilles
24 Pages
-
Swirl Diffusers Type FDE
6 Pages
-
Swirl Diffuser Type VDW
20 Pages
-
The art of handling air
80 Pages