Catalog excerpts
TOSHIBA Leading Innovation » AIR CONDITIONING FOR LARGE BUILDINGS SuperModularMultiSystem
Open the catalog to page 1Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and cost-effective, Toshiba aims at the heart of growing global pollution. Such inspiration takes team spirit even more than competitive spirit. We lead initiatives with innovators in academia, industry and government to think bigger, act bolder and move faster toward more eco-friendly solutions. To sustain better qualities of life, we have to take better care of business and the environment in the long run. Change is in the air. Together, we can...
Open the catalog to page 2The Super Modular Multi System opens up a new dimension in air conditioning. World’s best class energy savings Greater installation flexibility Improved operation control 2
Open the catalog to page 35 Feature 5 World’s Best Class Energy Savings 9 Greater Installation Flexibility 11 Improved Operation Control 13 Model Line-up 13 Outdoor unit 18 Indoor unit 19 4-way Air Discharge Cassette Type 21 Compact 4-way Cassette (600 × 600) Type 23 2-way Air Discharge Cassette Type 25 1-way Air Discharge Cassette Type 27 Concealed Duct Type 29 Concealed Duct High Static Pressure Type 31 Slim Duct Type 33 Ceiling Type 35 High-wall Type (1 series) 36 High-wall Type (2 series) *European market only 37 Floor Standing Concealed Type 38 Floor Standing Cabinet Type 39 Floor Standing Type 40 Fresh Air...
Open the catalog to page 53.5 4.0 4.5 5.0 5.5 6.0 4.63 4.54 4.56 3.83 4.56 3.83 3.83 3.95 COP 10HP 20HP 30HP 40HP HP 100% 80% 50% Heating temperature condition: Outdoor 7ºCdb/6ºCwb, Indoor 20ºC 5.73 5.51 5.54 5.53 World’s Best Class Energy Savings time h 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 % Capacity load Capacity load 0 20 40 60 80 100 COP of 4.25* achieved by Toshiba’s unrivalled Super Modular Multi System (SMMS) technologies and newly developed components * 8HP CDU system, heating operation SMMS high performance COP Partial load performance is the most important value for a VRF with fluctuating...
Open the catalog to page 6World’s Best Class Energy Savings Greater Installation Flexibility Improved Operation Control New large-diameter propeller fan (flash wing fan) The concave leading edge of the fan blades reduces flow interference between adjacent blades. Enlarged fan diameter ö630¨ ö710 Concave leading edge Outdoor heat-transfer - Compact heat-transfer tube with intakes on four sides. - Heat-transfer tube with improved heat-transfer coefficient of the inner surface. Configuration of the finned heattransfer tube Twin-rotary DC compressor Two DC twin-rotary compressors (dual configuration) are equipped per...
Open the catalog to page 7Reliability With dual-rotation, the load is distributed more evenly — this means that the operating sequence of the outdoor units and the individual compressors is rotated to spread the operating hours more evenly. As the compressors are all inverter driven, power surges are eliminated. Over- or under-utilisation of power, typical for non-inverter compressors is eliminated, and there is no on/off power surge as the system adjusts to the demand required by the occupant or system. The use of inverter compressors reduces the risk of compressor failure, more common in standard non-inverter...
Open the catalog to page 8World’s Best Class Energy Savings Greater Installation Flexibility Improved Operation Control World’s Best Class Energy Saving Toshiba Carrier Commitment to the Environment - Reduced level of emission of CO2 Protects against global warming Response to energy problems Established and promoted goals for reducing the amount of energy used in all production activities 25% improvement per basic unit in total sales by 2010 taking 1990 as a reference - Reduced level of emission of chemical substances 30% reduction by 2005 taking 2000 as a reference - Zero emission of harmful substances Achieved...
Open the catalog to page 9Greater Installation Flexibility Farthest equivalent length: 175 m Maximum actual length: 150 m Maximum length from first branch: 65 m Maximum indoor difference: 30 m Maximum height difference - Outdoor unit is higher than indoor unit: 50 m Outdoor unit is lower than indoor unit: 40 m The pipe runs for the SMMS have been extended to offer greater application flexibility. Flexible branching The versatility of the SMMS means that virtually any imaginable configuration of the refrigerant Y-type branches and/ or header piping can be used in an application to give the shortest, most...
Open the catalog to page 10World’s Best Class Energy Savings Greater Installation Flexibility Improved Operation Control Up to 48 units can be connected at up to 135% outdoor unit capacity in a single cooling system. - Allows smooth response to floors with small rooms and tenants who change layouts often. Wide variety in our indoor unit line-up World-class line-up of 14 types of indoor units. Up to 48 indoor unit connections 30 m Height between indoor and outdoor units (Outdoor unit higher than indoor unit) World’s Top Class 10
Open the catalog to page 11Improved Operation Control Optimal refrigerant control – When a multiple number of indoor units are connected, an insufficient or excess amount of refrigerant may be supplied to indoor units depending on the difference in length of the connection pipe from the outdoor unit. – This is caused by pressure loss and heat leaks as the refrigerant travels through the pipes, resulting in incorrect amounts of refrigerant being supplied to the indoor units. – Optimal refrigerant control uses a multiple number of refrigerant sensors to detect the air conditioning status of each indoor unit and control...
Open the catalog to page 12World’s Best Class Energy Savings Greater Installation Flexibility Improved Operation Control Toshiba Original These controls realize stable oil supplies. 1) Oil balance control 2) Oil supply control 3) Oil supply control between outdoor units Oil level detection system 1) Oil balance control This control equalizes amount of oil between two compressors. 3) Oil supply control between outdoor units This control supplies oil accumulated in the oil tank of each outdoor unit to the outdoor unit with insufficient oil. 2) Oil supply control This control accumulates oil in the oil separator. When...
Open the catalog to page 13All TOSHIBA air conditioning catalogs and technical brochures
-
RAS Multi-Split Indoor Units
1 Pages
-
HM_UTP
2 Pages
-
HM_MUT
2 Pages
-
GM_UT
2 Pages
-
GV_AT(8)P
2 Pages
-
HWS-_XWH PRODUCT SHEET
2 Pages
-
MMD-VN(K) PRODUCT SHEET
2 Pages
-
MMC-AP_HP PRODUCT SHEET
1 Pages
-
MMU-AP_7MH PRODUCT SHEET
1 Pages
-
MMK-AP_H1 PRODUCT SHEET
1 Pages
-
BROCHURE MULTISPLIT SYSTEM
16 Pages
-
Toshiba R32 refrigerant
6 Pages
-
TOSHIBA ESTIA 2020
14 Pages
-
CATALOGUE VRF
80 Pages
-
SHORAI EDGE
5 Pages
-
MIRAI R32
2 Pages
-
Brochure SMMS-e
20 Pages
-
ESTIA brochure
8 Pages
-
RAS R32 Seiya Brochure
8 Pages
-
R32 Bi-flow Console Brochure
8 Pages
-
ciat-product-range-brochure
20 Pages
-
DAISEIKAI 9
8 Pages
-
MIRAI
8 Pages
-
R32 Refrigerant
6 Pages
-
Shorai R32
10 Pages
-
RAS Multi-split R32
16 Pages
-
New LC DX Air Curtain Range
3 Pages
-
SMMSe VRF outdoor units
12 Pages
-
General catalog for large buildings
106 Pages
-
SDI / DI series
23 Pages
-
Super DAISEIKAI
4 Pages