SDI/DI
23Pages

{{requestButtons}}

Catalog excerpts

SDI/DI - 1

TOSHIBA Leading Innovation »

Open the catalog to page 1
SDI/DI - 3

03 Comfort Cost Saving An efficient use of time

Open the catalog to page 3
SDI/DI - 4

Super Digital Inverter Very efficient energy consumption = Keeps down operating costs Heater operation is possible starting from an outdoor temperature of -20°C :'-';;'^| I (RAV-SP1104AT-E, -SP1404AT-E) 1 9 I 1 = Creates a comfortable space even during cold winters Low-noise design. If the outdoor temperature is 30°C or less, operates at under 45 dB Pipes can be reused (RAV-SP1104AT-E, -SP1404AT-E) Compatible with pipes up to 75 meters long (RAV-SP1104AT-E, -SP1404AT-E) 1^B^> <^~- = Enables the outdoor unit to be installed out of sight Increases installation flexibility Operation in Power...

Open the catalog to page 4
SDI/DI - 5

Not only are operating costs minimised, but carbon emissions are cut, helping in the fight against global warming. 2 HP 3 HP 4 HP 5 HP 3.46 3.96 4.52 3.68 SDI / New 4-way cassette 5.0 (EER) 4.0 3.0 2.0 1.0 0.0 2 HP 3 HP 4 HP 5 HP 3.21 3.21 3.22 3.22 DI / New 4-way cassette 5.0 4.0 3.0 2.0 1.0 0.0 (EER) 05 Excellent Energy Efficiency Ratio

Open the catalog to page 5
SDI/DI - 6

I New SDI Sries 4 New Models with Enhanced Energy Efficiency (RAV-SP1104AT-E, -SP1404AT-E) Has excellent efficiency, not only under rated EER conditions, but also during partial load, which is the larger part of actual operating conditions. 100% LOAD partial LOAD In addition to achieving a top ranking during 100% load (rated) conditions... For most of the year, the air conditioner (cooler) operates while the outdoor temperature is less than 30°C. At this time, the air conditioner load is approximately 50%, and at this level the EER is significantly greater than during rated conditions. This...

Open the catalog to page 6
SDI/DI - 9

Available up to 3.5 m Drain-checking hole 09 Model RAV-SM562MUT-E Panel RBC-UM11PG(W)-E Compact 4-way Cassette Type Perfect for grid system ceiling 1. This compact unit (575x575) fits perfectly into ceilings and matches standard architectural modules, without the need to cut ceiling tiles. 2. The compact & stylish panel design is ideal for fashionable restaurants, shops and offices. 3. The flaps fold tightly against the ceiling when operation stops so that the ceiling is affected only slightly even if air-conditioning is installed. 1. The slim design is only 268 mm in height even when an...

Open the catalog to page 9
SDI/DI - 10

SDI Twin SDI Outdoor unit Indoor unit RAV-SP562AT-E RAV-SM562MUT-E RAV-SP1104AT-E RAV-SM562MUT-E Cooling capacity kW 5.0 10.0 Cooling capacity, min-max kW 2.2-5.6 2.6-12.0 Power input, cooling kW 1.53 2.67 EER W/W 3.27 3.75 Energy efficiency class, cooling A A Annual energy consumption kWh 765 1335 Heating capacity kW 5.6 11.2 Heating capacity, min-max kW 2.2-7.0 2.4-13.0 Power input, heating kW 1.54 2.67 COP W/W 3.64 4.19 Energy efficiency class, heating A A Power supply V-ph-Hz 220/240-1-50 220/240-1-50 DI Twin DI Outdoor unit Indoor unit RAV-SM563AT-E RAV-SM562MUT-E RAV-SM1103AT-E...

Open the catalog to page 10
SDI/DI - 11

Inverter Allows step-less regulation of the airconditioner’s power, which reduces energy consumption and improves comfort. Auto-turn Louvres Air outlet grilles move automatically to fill every corner of the room with warm or cool air. Automatic Air Volume Control Depending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low. Long-life Filter Built-in long-life filter makes maintenance easier. Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into...

Open the catalog to page 11
SDI/DI - 13

Wide range of applications High static pressure High-lift drain pump Inverter Allows step-less regulation of the airconditioner’s power, which reduces energy consumption and improves comfort. Automatic Air Volume Control Depending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low. Long-life Filter Built-in long-life filter makes maintenance easier. Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. Automatic Cooling/Heating...

Open the catalog to page 13
SDI/DI - 15

Comfortable ambience Installation efficiency Inverter Allows step-less regulation of the airconditioner’s power, which reduces energy consumption and improves comfort. Auto-turn Louvres Air outlet grilles move automatically to fill every corner of the room with warm or cool air. Automatic Air Volume Control Depending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low. Long-life Filter Built-in long-life filter makes maintenance easier. Hot Start When using the heater for preheating or defrosting, stops the indoor fan...

Open the catalog to page 15
SDI/DI - 17

Inverter Allows step-less regulation of the airconditioner’s power, which reduces energy consumption and improves comfort. Auto-turn Louvres Air outlet grilles move automatically to fill every corner of the room with warm or cool air. Automatic Air Volume Control Depending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low. Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. Automatic Cooling/Heating Automatically switches between...

Open the catalog to page 17
SDI/DI - 18

SDI Twin SDI Outdoor unit Indoor unit RAV-SP562AT-E RAV-SM562KRT-E RAV-SP802AT-E RAV-SM802KRT-E RAV-SP1104AT-E RAV-SM562KRT-E RAV-SP1404AT-E RAV-SM802KRT-E Cooling capacity kW 5.0 6.9 10.0 12.3 Cooling capacity, min-max kW 2.2-5.6 2.2-8.0 2.6-12.0 2.6-13.5 Power input, cooling kW 1.39 2.40 2.77 3.88 EER W/W 3.60 2.88 3.61 3.17 Energy efficiency class, cooling A C A B Annual energy consumption kWh 695 1200 1385 1940 Heating capacity kW 5.6 8.0 11.2 14.0 Heating capacity, min-max kW 2.2-7.0 2.2-9.5 2.4-13.0 2.4-16.5 Power input, heating kW 1.55 2.40 2.80 3.83 COP W/W 3.61 3.33 4.00 3.66...

Open the catalog to page 18
SDI/DI - 19

Toshiba Digital Inverters & Super Digital Inverters are operated with an easy-to-use remote controller. Wired remote controller Simple wired remote controller Appearance Model name RBC-AMT32E RBC-AS21E2 Wireless remote controller kits Appearance Remarks Model name RBC-AX31U(W)-E RBC-AX22CE2 TCB-AX21E2 For under ceiling type (Series 2) For 4-way cassette type (Series 4) Integral receiver Integral receiver Standalone receiver 19 Remote Controllers Combinations RBC-AMT32E RBC-AS21E2 RBC-AX31U(W)-E RBC-AX22CE2 TCB-AX21E2 Compact 4-way Series 2 RAV-SM562MUT-E OK OK OK 4-way Cassette Series 4...

Open the catalog to page 19

All TOSHIBA air conditioning catalogs and technical brochures

  1. HM_UTP

    2 Pages

  2. HM_MUT

    2 Pages

  3. GM_UT

    2 Pages

  4. GV_AT(8)P

    2 Pages

  5. CATALOGUE VRF

    80 Pages

  6. SHORAI EDGE

    5 Pages

  7. MIRAI R32

    2 Pages

  8. DAISEIKAI 9

    8 Pages

  9. MIRAI

    8 Pages

  10. Shorai R32

    10 Pages

Archived catalogs

  1. ESTIA

    8 Pages

  2. SMMS

    64 Pages

  3. SHRM

    16 Pages

  4. MiNi SMMS

    26 Pages

  5. daiseikai

    4 Pages