Catalog excerpts
AIR-TO-AIR HEAT EXCHANGER MMD-VN(K) AIR-TO-AIR HEAT EXCHANGER WITH DX COIL MMD-VN(K) ventilation products are using exhaust air + DX coil to pre-condition the incoming air, thus reducing the cooling or heating load and the overall size of the required air conditioning system. CAPACITY LOCAL CONTROLS SOUND PRESSURE LEVEL OUTDOOR UNITS COMPATIBILITY Features Without humidifier Model name With humidifier Cooling Capacity Heating Capacity Power supply Temperature exchange efficiency Cooling Enthalpy exchange efficiency Heating Power input (Heat exchange mode) Running current Standard air flow Fan unit External static pressure Air flow limit Extra High High Low Extra High High Low Extra High High Low Extra High High Low Extra High High Low Extra High High Low Extra High High Low Lower limit Upper limit System Amount Feed water pressure Extra High High Low Sound pressure Sound power Zinc hot dipping steel plate Zinc hot dipping steel plate Heat exchanger Finned tube Heat-insulating material Flexible urethane foam Standard filter & High efficiency filter Controller Connecting piping Gas side Liquid side Drain port (Nominal dia.) Water supply connection (Port size) Around unit Outdoor Air (OA) Operating range Return Air (RA) Finned tube Flexible urethane foam Standard filter (Gravitational method 82%) & High efficiency filter (Colormetric method 65%) Remote controller (Separately sold parts) 3/8" 1/2" 1/2" 1/4" 1/4" 1/4" 25 (Polyvinyl chloride tube) R1/2 -10 - 40°C . RH ≤80% -15 - 43°C . RH ≤80% 5 - 40°C . RH ≤80% Cooling and heating capacities are based on the following conditions: cooling capacities are based on: indoor temperature: 27°CDB/19°C WB, Outdoor temperature: 35°C DB Heating capacities are based on: indoor temperature: 20°C DB, Outdoor temperature: 7 ° CDB/6°C WB. The figures in ( ) indicate the heat reclaimed from the heat recovery ventilator.
Open the catalog to page 1AIR-TO-AIR HEAT EXCHANGER WITH DX COIL Drawings Sound pressure levels 90 Extra High High Low Extra High High Low Octave band sound pressure level (dB) Extra High High Low Octave band sound pressure level (dB) Octave band sound pressure level (dB) Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) Accessories Type Model name Dedicated remote controller for air-to-air heat exchanger On/off optional PCB for air-to-air heat exchanger Integrated functions: fan speed, freecooling, air balance volume rate, temperature management and timer....
Open the catalog to page 2All TOSHIBA air conditioning catalogs and technical brochures
-
RAS Multi-Split Indoor Units
1 Pages
-
HM_UTP
2 Pages
-
HM_MUT
2 Pages
-
GM_UT
2 Pages
-
GV_AT(8)P
2 Pages
-
HWS-_XWH PRODUCT SHEET
2 Pages
-
MMC-AP_HP PRODUCT SHEET
1 Pages
-
MMU-AP_7MH PRODUCT SHEET
1 Pages
-
MMK-AP_H1 PRODUCT SHEET
1 Pages
-
BROCHURE MULTISPLIT SYSTEM
16 Pages
-
Toshiba R32 refrigerant
6 Pages
-
TOSHIBA ESTIA 2020
14 Pages
-
CATALOGUE VRF
80 Pages
-
SHORAI EDGE
5 Pages
-
MIRAI R32
2 Pages
-
Brochure SMMS-e
20 Pages
-
ESTIA brochure
8 Pages
-
RAS R32 Seiya Brochure
8 Pages
-
R32 Bi-flow Console Brochure
8 Pages
-
ciat-product-range-brochure
20 Pages
-
DAISEIKAI 9
8 Pages
-
MIRAI
8 Pages
-
R32 Refrigerant
6 Pages
-
Shorai R32
10 Pages
-
RAS Multi-split R32
16 Pages
-
New LC DX Air Curtain Range
3 Pages
-
SMMSe VRF outdoor units
12 Pages
-
General catalog for large buildings
106 Pages
-
SDI / DI series
23 Pages
-
Super DAISEIKAI
4 Pages