Definition of Unit Price
The document defines the unit price for plastic floating floor pedestals, encompassing all costs such as materials, labor, transportation, and insurance. These pedestals are designed to achieve the desired floor elevation and comply with the TS 13776 standard.
Overall Purpose
The specification details the use of plastic floating floor pedestals for both indoor and outdoor applications. It highlights the prime contractor's responsibility for ensuring material quality and manufacturing, irrespective of project manager approvals.
Documents Related to Product
Products must adhere to TS 13776 standards and possess a TSE certificate. Any discrepancies between standards and specifications require approval from the project owner.
Deliveries
Manufacturing drawings need approval before delivery. Samples and model applications must be approved prior to project use.
Quality Assurance
Materials should be sourced from experienced manufacturers, with on-site assembly conducted by skilled teams.
Delivery, Storage, and Handling
The prime contractor is responsible for material handling and storage, ensuring no damage occurs. Materials should be stored in a dry, protected environment.
Warranty
The warranty covers five years for materials and one year for workmanship. The prime contractor will repair or replace defects within the warranty period.
Materials
Materials must meet specified quality and dimensions, be weather-resistant, and recyclable. The pedestals should support a minimum of 900 kg and be adjustable in height.
Inspection and Preparation
The contractor must assess and prepare areas before application, considering weather conditions and protecting finished work.
Assembly
Assembly must adhere to specifications and approved drawings. Calibration shims and joint structures ensure proper alignment and stability.
Lath Application
Threshold elevations are marked, and a modulation plan is approved before starting. Slope apparatus manage high slopes, and final coatings are secured with screws.
Teak Oil Application Procedure
  • Avoid application on rainy or very hot days.
  • Clean the floor with a damp cloth to remove dust before application.
  • Apply teak oil twice using a flat brush and a clean, dry cloth.
  • Spread the oil evenly, avoiding thick application (70 gr/m2).
  • Wait at least 16 hours between applications.
  • Maintenance should be done once or twice a year depending on exposure conditions.
Tile Application Procedure
  • Mark and complete threshold elevations on all side parapets.
  • Determine modulation to minimize edge cuts and ensure visual satisfaction, subject to PRIME CONTRACTOR approval.
  • Start application from any corner using multiple slope apparatus to manage high slopes.
  • Use TOKOZs for positioning, ensuring each paving stone corner is supported.
  • Use calibration adjusting shims to address coating material differences and for noise isolation if needed.
  • Select TOKOZs with variable adjustment height for precise millimetric measurement according to final elevation.
See more

Catalog excerpts

TECHNICAL SPECIFICATIONS PREMIUM & CLEVER-1

TECHNICAL SPECIFICATIONS PREMIUM & CLEVER PLASTIC RAISED FLOATING FLOOR PEDESTALS (USED FOR INDOORS AND OUTDOORS) TOKOZ PLASTIC & BUILDING MATERIALS INTERNATIONAL

 Open the catalog to page 1
TECHNICAL SPECIFICATIONS PREMIUM & CLEVER-2

TOKOZ PLASTIC & BUILDING MATERIALS INTERNATIONAL 1. DEFINITION OF UNIT PRICE 1.1. FLOATING FLOOR PEDESTALS CALLED AS PLASTIC ADJUSTING WEDGE It is a turnkey price per square meter, including expenses such as any material and losses/damages, workmanship, vehicle, machine, equipment rent and expenses, correction of defective manufacturing and / or removing and re-paving, transportation, vertical and horizontal handling, storage costs and insurance that are required to perform pavement process by using TOKOZ and complementary products in order to attain intended final elevation and eliminate the...

 Open the catalog to page 2
TECHNICAL SPECIFICATIONS PREMIUM & CLEVER-3

TOKOZ PLASTIC & BUILDING MATERIALS INTERNATIONAL 2.4 QUALITY ASSURANCE 2.4.1. All coating materials should be provided from a manufacturer or dealer with at least 5 years successful experience of materials. 2.4.2. Manufacturing projects must be approved before the implementation starts. 2.4.3. It should be a certificate which assert that all materials to be used are provided from responsible sources. 2.4.4. On-site montage should be performed by experienced teams, who have experience in similar projects or will be recommended by the manufacturer. 2.5 DELIVERY, STORAGE AND HANDLING 2.5.1. All...

 Open the catalog to page 3
TECHNICAL SPECIFICATIONS PREMIUM & CLEVER-4

TOKOZ PLASTIC & BUILDING MATERIALS INTERNATIONAL 3. MATERIALS 3.1 MAIN ELEMENTS All materials will have the quality and dimensions specified in the project. Unless otherwise indicated, technical specifications presented in the following tables and types of material shown in the details will use in the material selection. All products to be used in the system must be resistant to adverse weather conditions, corrosion and chemicals and be recyclable. The required bearing capacity per each pedestal should be a minimum of 900 kg. Foot system and ancillary products must be polypropylene-based and...

 Open the catalog to page 4
TECHNICAL SPECIFICATIONS PREMIUM & CLEVER-5

TOKOZ PLASTIC & BUILDING MATERIALS INTERNATIONAL 3.1.1 HEAD Top basement with top place and cylinder body is a gear system in which a height adjustment can be made, connecting to lower base or elevator through threads. There must be holes that positioning (joint) bars will be mounted on the top surface of topping base in order to use in the applications of coating plates with triangular, pentagonal and hexagonal, as well as rectangular, surfaces. A crack must be in the lowest gear housing to ensure that it does not disjoint from bottom base or coupler. 3.1.2 BASE Bottom basement must be designed...

 Open the catalog to page 5
TECHNICAL SPECIFICATIONS PREMIUM & CLEVER-6

TOKOZ PLASTIC & BUILDING MATERIALS INTERNATIONAL 3.1.4 JOINT STRUCTURES Thickness should be four alternatives in the form of = 2-4-6-8 mm. It will be used in the areas to be paved. Bars should be able to fasten mechanically in a way that top base, bottom base and coupler will remain together without using another junction piece. Apart from these products, an alternative should also have to a single part of joint apparatus with crosshair and 4 mm-thick. 3.1.5 CARCASS FIXING ELEMENTS It will be used in the areas to be laid wood deck (linear). Carcass fixing elements should be designed in a way...

 Open the catalog to page 6
TECHNICAL SPECIFICATIONS PREMIUM & CLEVER-7

TOKOZ PLASTIC & BUILDING MATERIALS INTERNATIONAL 3.2 AUXILIARY COMPONENTS FOR APPLICATIONS 3.2.1 AUXILIARY COMPONENTS FOR WOOD APPLICATIONS 3.2.1.1 Stainless, galvanized or plastic (polypropylene) hidden screwing apparatus 3.2.1.2 Stainless screws 3.2.1.3 Teak oil or protective paint 3.2.1.4 Tile removal apparatus (for tile deck applications) 3.2.1.5 Other hand tools necessary for completing the application 3.2.2 AUXILIARY COMPONENTS FOR STONE APPLICATIONS 3.2.2.1 Stone removal apparatus 3.2.2.2 Other hand tools necessary for completing the application 4. INSPECTION AND PREPARATION 4.1. CONTRACTOR...

 Open the catalog to page 7
TECHNICAL SPECIFICATIONS PREMIUM & CLEVER-8

TOKOZ PLASTIC & BUILDING MATERIALS INTERNATIONAL 5.1.11 Defective products should not be used and even if the laying completes, these products detected should be replaced with new ones. 5.1.12 After the laying, application areas should be cleaned and should be put under protection if necessary. 5.1.13 Final elevation of raised flooring should be established with approval of the project architect, and surface slope should be controlled with rope and gauge throughout the entire application. 5.2 LATH APPLICATION Threshold elevations on areas prepared for the application will be marked and completed...

 Open the catalog to page 8
TECHNICAL SPECIFICATIONS PREMIUM & CLEVER-9

TOKOZ PLASTIC & BUILDING MATERIALS INTERNATIONAL 5.3 TILE APPLICATION Threshold elevations on areas prepared for the application will be marked and completed on all side parapets. A modulation will be determined in a way that can minimize the edge cut and provide a visually saturation by studying on the project, and will submit for PRIME CONTRACTOR’ approval. Application can start from any corner. More than one slope apparatus will be placed and used on the top of each other in line with slope ratio. In this way, it will also allow high slopes to eliminate or reduce. Slope apparatus with different...

 Open the catalog to page 9
TECHNICAL SPECIFICATIONS PREMIUM & CLEVER-10

TOKOZ PLASTIC & BUILDING MATERIALS INTERNATIONAL