evolution plan GD
8Pages

{{requestButtons}}

Catalog excerpts

evolution plan GD - 1

Planning Guide Limited Use/Limited Application Elevator ASME A17.1 Part 5.2 August 2008 National Wheel-O-Vator A Division of ThyssenKrupp Access ThyssenKrupp Evolution Limited Use/Limited Application Elevator

Open the catalog to page 1
evolution plan GD - 3

Page 3 The Evolution elevator is designed to meet the requirements of ASME A17.1 Part 5.2, when properly equipped and installed. Mechanical Equipment: • 1:2 roped hydraulic single stage cylinder with line rupture valve • 5 hp submersible motor with two speed valve assembly • 208/230V, 60 Hz, 30 amp single phase power supply • 8 lb. T-rail system • Two 3/8" diameter wire rope cables • Sling assembly • Forged rope sockets • Buffer springs and stands Car and Appointments: • Car sized to your application • Autumn white interior metal panels • Matching ceiling panel • Unfinished fire rated wood...

Open the catalog to page 3
evolution plan GD - 4

Page 4 Evolution LU/LA The drawings shown below illustrate the standard car size of 42"x 54" with 36" doors. Car sizes for Types 3 and 4 are 51' x 51". (All dimensions are shown in inches.) Optional car sizes of 42" x 60" and 48" x 54" are also available. Consult National Wheel-O-Vator for hoistway details. Note: To comply with ICC/ANSI A117, the minimum car size for new construction is 42" x 54". HOISTWAY REQUIREMENTS TYPE 1 Left hand car shown, right hand opposite. 73 1/4" Depth TYPE 2 40 1/2" 66" Width TYPES 3 and 4 Car Type 3 shown, Car Type 4 opposite. 73 3/4" Depth 79 3/4" Width 48...

Open the catalog to page 4
evolution plan GD - 5

Page 5 Hoistway Notes: • A load bearing wall is required to sustain rail reactions. See page 6 for rail reactions. • The hoistway pit floor must resist a dynamic force of 5800 lbs. • 132" overhead clearance is required above the top landing floor. • 14" minimum pit. (A Pit Clearance Device is required to attain required refuge space). • Hoistway sizes reflect running and access clearances only. Consult your local authority to assure compliance with state and local codes. • The hoistway is required to be free of all pipes, wiring, and obstructions not related to the operation of the...

Open the catalog to page 5
evolution plan GD - 6

Page 6 Evolution LU/LA Power Unit 1400 lb. Capacity 1:2 Roped Hydraulic Drive 132" Min. Overhead Fully Automatic, Side Opening, Sliding Doors Pit Depth - 38" standard (14" optional minimum) Notes: 1. All dimensions are shown in inches. 2. See hoistway requirements for the location of the door centerline. 3. Door panels and frame are primer gray. 4. Elevator must be installed before rough opening is finished. Fuly Automatic , SIDE Opening, Sliding CAR AND HOISTWAY DOOR ROUGH OPENING 92" ±1/4" Hoistway width ±1/4" (see pg 4) 4" min. - 8" max. Measured from top of finished floor RAIL REACTIONS...

Open the catalog to page 6
evolution plan GD - 7

Page 7 PART 1 GENERAL 1.01 SECTION INCLUDES: A. Limited Use / Limited Application (LU/LA) commercial elevator with 1:2 roped hydraulic lift system. 1.02 WORK INCLUDED: A. Furnish all labor and materials, equipment and incidentals necessary to assemble and erect the commercial elevator, complete with a remote power unit and all hoses, rails, brackets, connections and controls essential for proper operation. 1.03 WORK BY OTHERS: A. Hoistway: Construct a hoistway of the size required by the manufacturer, complete with all demolition, additional framing, headers and framing components necessary...

Open the catalog to page 7
evolution plan GD - 8

Page 8 Evolution LU/LA ANSI A117.1 requirements. 9. Visual feedback: Provide digital floor position indicator in control panel, indicator lights acknowledging call for car, and arrow lights indicating car’s next travel direction. 10. Standard Color: Autumn White 11. Audible feedback: Provide audible signal indicating car arrival and direction of travel. 12. Tactile feedback: Provide tactile/Braille characters on all car and hall call push buttons, and hoistway door jambs 13. Interior lighting: Provide overhead light fixtures that automatically turn on when the car is in operation and turn...