Installation Instructions: The solid fuel heater must be connected to an existing chimney using a short, straight, and tight connector. Compliance with local, national, and European standards is required. Ensure adequate combustion air supply, especially in sealed rooms. Chimney properties should be calculated according to DIN 4705 standards.
General Safety Instructions: Heater surfaces can become extremely hot. Use protective gear and keep children away.
Acceptable Fuel: Only air-dried wood logs and lignite briquettes are acceptable. Wood logs should have a maximum humidity of 20%.
Firing: Initial firing may produce an odor. Ensure proper ventilation and avoid flammable liquids for ignition.
Operating Multiple Fireplaces: Ensure adequate combustion air supply when operating more than one fireplace in the same room.
Transition Season Operation: Use smaller fuel quantities and open the primary air supply slider during warmer temperatures to stabilize chimney draught.
Cleaning and Checking: Flue pipes should be checked and cleaned annually. Regular chimney sweeping is required.
Versions: Heaters with spring fireplace doors can be connected to shared chimneys if compliant with DIN 4705 part 3.
Combustion Air: Adequate combustion air intake is crucial, especially in rooms with tight windows and doors.
Fire Protection: Maintain specified distances from flammable structures and use non-flammable hearths.
Spare Parts: Only use manufacturer-approved spare parts. No modifications are allowed.
Warning in Case of Chimney Fire: Close all air holes immediately and contact the fire brigade.
Nominal Heating Capacity and Combustion Air Adjustment: The heater's nominal heating capacity is 8.0 kW.
Space Heating Capacity: Heating capacity varies based on room insulation and conditions.
Technical Data: Details on heater capacity, weight, and chimney properties are provided. The guarantee covers defects for two years.
Supplementary Clause: Instructions for disposing of packaging and the product at the end of its service life are provided.
Specifications and Procedures: Chimneys should be cleaned regularly, and stoves inspected annually. Stoves with self-closing doors can connect to shared chimneys if compliant with DIN EN 13384-2 standards.
Combustion Air Requirements: Adequate ventilation is necessary for combustion. Additional fresh air supply may be needed.
Fire Safety: Minimum distances from combustible materials are specified.
Replacement Parts and Warranty: Only manufacturer-approved parts should be used. The warranty is valid for two years.
Chimney Connection: Type 1 stoves can connect to shared chimneys.
Additional Notes: Emphasizes the importance of using dry wood and proper fuels.
Specifications and Installation Instructions: Detailed instructions for installation and operation of solid fuel stoves are provided.
Safety and Operational Guidelines: Safety precautions include maintaining a safe distance from flammable materials and ensuring adequate ventilation.
Fire Prevention and Maintenance: Fire prevention measures include using non-flammable materials and regular cleaning.
Performance and Technical Data: The nominal heat output is 8.0 kW, with specific instructions for regulating combustion air.
Warranty and Replacement Parts: The warranty covers defects for two years, and only manufacturer-approved parts should be used.
Environmental and Disposal Recommendations: Recycling packaging materials and responsible disposal of the stove are recommended.
See more

Catalog excerpts

FALUN II-1

FALUN, KIRUNA II, LANDSHUT Installation and Operation Manual solid fuel heater FALUN, LANDSHUT, LANDSHUT II, ALVESTA, ALVESTA II, KIRUNA II, GRAZ, CREMONA, GRENOBLE, ATOMIC, RIBE tested according to the standard EN 13240 1. Installation Instruction The heater has been designed to allow simple connection to an existing chimney by a single connecting piece. The connecting piece must be as short and straight as possible, in a horizontal position or slightly inclined. The piece must be tight. Be sure that all local regulations, including those concerning both national and European standards on construction and fire prevention, are respected during installation. Inform the competent inspector prior to installation. Be sure that combustion air supply is sufficient; particularly in rooms where windows and doors are closed tight. Chimney properties shall be calculated in accordance with DIN 4705 parts 1 and parts 2, eventually also part 3, with the three values stated in this manual. The heater must stand on a hearth with adequate bearing capacity. If bearing capacity is too low, adequate measures must be taken (e.g. a board must be laid to split weight). 2. General Safety Instructions Fuel combustion emits calorific energy that heats the surface of the heater, combustion chamber door, door and control elements handles, safety glass, flue pipes, and eventually also the front of the heater. Do never touch those parts without adequate safety wear or elements (fireproof gloves etc.). Warn children of such danger and make sure they do not stay close to heater when in operation. 3. Acceptable Fuel Fuels acceptable for burning include wood logs of up to 25 cm in length and 30 cm in circumference, and lignite briquettes. Make sure that only air dried wood logs are used. Burning of waste, and plastics in particular, is forbidden by law on emissions. Besides, such fuel may cause damage to the fire place and chimney and subsequently may injure health and smell may annoy your neighbours. Air dried wood logs with 20% maximum humidity may be obtained after at least one year (soft wood) or two years (hard wood) of drying. Wood is not slow combustion fuel and thus, continuous heating throughout the night is not possible when burning wood. Liquid fuel is unacceptable. 4. Firing During the first firing bad smell due to drying of protection paint is inevitable but the smell shall fade quickly. Make sure the room with the heater is well aerated when firing. Quick firing is essential because incorrect procedure may cause increased emissions. Add more fuel as soon as firing fuel catches fire. Do never use alcohol, petrol or other flammable liquids for firing. Do always use some paper, wood chips, and a small amount of fuel for that. Make sure that primary and secondary air is supplied to heater when firing. Make sure that heater is under control during firing. 5. Operating More than One Fireplace Make sure that combustion air supply is sufficient when operating more than one fireplace in one room or within the same air system. 6. Transition Season Operation When exterior temperature rise during transition season draught can decrease at low burning capacity and flue gas may not be evacuated completely. In such case add only small quantities of fuel and open the slider of primary air supply so that loaded fuel burns more quickly (flame) and draught gets steady. Ash needs to be raked carefully more often to enhance air circulation below fireplace. 7. Cleaning and Checking Heater flue pipes need to be checked for deposit and eventually swept at least once a year or more often, e.g. while sweeping chimney. Make sure your chimney is swept regularly by a chimneysweep. The frequency of sweeping shall be defined by competent inspector. Heater should be checked by an expert every year. 8. Versions Heaters with spring fireplace door can be connected to a chimney with multiple taking for other heaters and fireplaces provided that dimensions of the chimney are in compliance with DIN 4705 part 3. The door of the heater with spring fireplace door must always be closed during operation, except for firing, fuel charging, and ash removing. Otherwise operation of other equipments connected to the chimney may be affected or flue gas may leak. 9. Combustion Air Since heaters are fireplaces depending on surrounding air and take combustion air from the room, adequate intake of combustion air is vital. In rooms with tight windows and doors (e.g. as energy-saving measure) fresh air intake may be low and thus affect draught of the heater. Also your well-being may be affected; even your safety may be threatened. It may sometimes be necessary to assure adequate intake of fresh air e.g. by installing air shutter close to heater or by combustion air pipe leading to exterior or to a well aerated room

 Open the catalog to page 1
FALUN II-2

FALUN, KIRUNA II, LANDSHUT (except boiler room). In particular it is vital that combustion air pipes are open during operation of fireplace. Steam flues located in the same room with fireplace may affect heater’s operation (smoke may leak to inhabited room despite closed fireplace door) and therefore must never be operated parallelly with the heater. 10. Fire Protection Distance from flammable structures and furniture To assure adequate heat protection, a minimum distance of 15 cm in the back and 20 cm on the sides is required between the heater and flammable structures and furniture. Fire protection...

 Open the catalog to page 2
FALUN II-3

FALUN, KIRUNA II, LANDSHUT Data for chimney properties calculation (at nominal heating capacity): Guarantee Shall any failure, malfunction, or surface defect occur on your heater within the guarantee period do never repair it by yourself. Aftersale service can be done only by the manufacturer or distributor. We guarantee the quality, function, and construction of the cooker for 2 years from the day of purchase: defects definitely occurred as a consequence of manufacturing defect will be remedied within short time at our cost under the condition that the heater - has been operated in conformity...