1. Catalogs
  2. Thorma Vyroba k.s.
  3. BORGHOLM keramik Top

BORGHOLM keramik Top

BORGHOLM keramik Top
1 / 19 PagesView full catalog

BORGHOLM keramik Top

Product catalog summary
Installation Instructions
The BORGHOLM II solid fuel heater requires connection to an existing chimney with a short, straight, and tight connecting piece. Compliance with construction and fire prevention standards is essential. Ensure adequate combustion air supply, especially in sealed rooms, and place the heater on a hearth with sufficient bearing capacity.
General Safety Instructions
The heater's surfaces become hot during use. Avoid touching without protection and keep children away.
Acceptable Fuel
Use only air-dried wood logs and lignite briquettes. Wood should be dried to a maximum humidity of 20%.
Firing
Initial firing may produce a smell from drying paint. Ensure ventilation and use appropriate materials for ignition. Avoid flammable liquids.
Operating More than One Fireplace
Ensure adequate air supply when using multiple fireplaces.
Transition Season Operation
Use smaller fuel quantities and adjust air supply to stabilize chimney draught during warmer seasons.
Cleaning and Checking
Annual cleaning of flue pipes and chimney sweeping is required. Yearly expert inspection is recommended.
Versions
Heaters with spring doors can connect to shared chimneys if compliant with standards. Keep doors closed during operation.
Combustion Air
Adequate air intake is crucial. Consider additional air supply installations if necessary.
Fire Protection
Maintain specified distances from flammable structures and use non-flammable hearth materials.
Spare Parts
Use only manufacturer-approved parts. No modifications allowed.
Warning in Case of Chimney Fire
Close air holes and call the fire brigade. Inspect chimney for damage afterward.
Nominal Heating Capacity and Combustion Air Adjustment
The heater's nominal capacity is 7.0 kW. Specific air slider settings and fuel quantities are provided.
Space Heating Capacity
Heating capacity varies with room insulation, with specific values for different scenarios.
Technical Data
The heater has a capacity of 7 kW, weighs 77-130 kg, and includes data for chimney calculations.
Guarantee
A 2-year warranty is provided against manufacturing defects, with conditions for proper operation.
Specifications
The stove is classified as a time-burning appliance with a nominal heat output of 7.0 kW.
Combustion Air
Stoves require adequate fresh air supply, with additional air supply installations recommended if necessary.
Fire Safety
Specified minimum distances from combustible materials and non-combustible floor protection are required.
Replacement Parts
Only use manufacturer-approved parts. Unauthorized modifications are prohibited.
Chimney Fire Warning
Incorrect or damp fuel can cause chimney fires. Close air openings and contact the fire department if needed.
Nominal Heat Output and Combustion Settings
The stove's nominal heat output is 7.0 kW, with specific air supply settings for different fuels.
Room Heating Capacity
The stove can heat rooms of varying insulation levels, with capacities from 98 m3 to 165 m3.
Technical Data
The stove weighs 77-130 kg and has a flue diameter of 150 mm.
Warranty
A 2-year warranty is provided, excluding parts exposed to direct fire.
See more

Catalog excerpts

BORGHOLM keramik Top-1

Installation and Operation Manual solid fuel heater BORGHOLM II, SANDERFORD II, BRUNSHOLM, TORINO, HÖRBY, ULSBORG, STOCKHOLM, LOHOLM, NANCY, COLMAR, AUGSBURG tested according to the standard EN 13240 1. Installation Instruction The heater has been designed to allow simple connection to an existing chimney by a single connecting piece. The connecting piece must be as short and straight as possible, in a horizontal position or slightly inclined. The piece must be tight. Be sure that all local regulations, including those concerning both national and European standards on construction and fire prevention, are respected during installation. Inform the competent inspector prior to installation. Be sure that combustion air supply is sufficient; particularly in rooms where windows and doors are closed tight. Chimney properties shall be calculated in accordance with STN 73 4201 and STN 73 4210 with the three values stated in this manual. The heater must stand on a hearth with adequate bearing capacity. If bearing capacity is too low, adequate measures must be taken (e.g. a board must be laid to split weight). 2. General Safety Instructions Fuel combustion emits calorific energy that heats the surface of the heater, combustion chamber door, door and control elements handles, safety glass, flue pipes, and eventually also the front of the heater. Do never touch those parts without adequate safety wear or elements (fireproof gloves etc.). Warn children of such danger and make sure they do not stay close to heater when in operation. 3. Acceptable Fuel Fuels acceptable for burning include wood logs of up to 25 cm in length and 30 cm in circumference, and lignite briquettes. Make sure that only air dried wood logs are used. Burning of waste, and plastics in particular, is forbidden by law on emissions. Besides, such fuel may cause damage to the fire place and chimney and subsequently may injure health and smell may annoy your neighbours. Air dried wood logs with 20% maximum humidity may be obtained after at least one year (soft wood) or two years (hard wood) of drying. Wood is not slow combustion fuel and thus, continuous heating throughout the night is not possible when burning wood. Liquid fuel is unacceptable. 4. Firing During the first firing bad smell due to drying of protection paint is inevitable but the smell shall fade quickly. Make sure the room with the heater is well aerated when firing. Quick firing is essential because incorrect procedure may cause increased emissions. Add more fuel as soon as firing fuel catches fire. Do never use alcohol, petrol or other flammable liquids for firing. Do always use some paper, wood chips, and a small amount of fuel for that. Make sure that primary and secondary air is supplied to heater when firing. Make sure that heater is under control during firing. 5. Operating More than One Fireplace Make sure that combustion air supply is sufficient when operating more than one fireplace in one room or within the same air system. 6. Transition Season Operation When exterior temperature rise during transition season draught can decrease at low burning capacity and flue gas may not be evacuated completely. In such case add only small quantities of fuel and open the slider of primary air supply so that loaded fuel burns more quickly (flame) and draught gets steady. Ash needs to be raked carefully more often to enhance air circulation below fireplace. 7. Cleaning and Checking Heater flue pipes need to be checked for deposit and eventually swept at least once a year or more often, e.g. while sweeping chimney. Make sure your chimney is swept regularly by a chimneysweep. The frequency of sweeping shall be defined by competent inspector. Heater should be checked by an expert every year. 8. Versions Heaters with spring fireplace door can be connected to a chimney with multiple taking for other heaters and fireplaces provided that dimensions of the chimney are in compliance with STN 73 4201 and STN 73 4210. The door of the heater with spring fireplace door must always be closed during operation, except for firing, fuel charging, and ash removing. Otherwise operation of other equipments connected to the chimney may be affected or flue gas may leak. 9. Combustion Air Since heaters are fireplaces depending on surrounding air and take combustion air from the room, adequate intake of combustion air is vital. In rooms with tight windows and doors (e.g. as energy-saving measure) fresh air intake may be low and thus affect draught of the heater. Also your well-being may be affected; even your safety may be threatened. It may sometimes be necessary to assure adequate intake of fresh air e.g. by installing air shutter close to heater or by combustion air pipe leading to exterior or to a well aerated room

 Open the catalog to page 1
BORGHOLM keramik Top-2

(except boiler room). In particular it is vital that combustion air pipes are open during operation of fireplace. Steam flues located in the same room with fireplace may affect heater’s operation (smoke may leak to inhabited room despite closed fireplace door) and therefore must never be operated parallelly with theatre. 10. Fire Protection Distance from flammable structures and furniture To assure adequate heat protection, a minimum distance of 20 cm in the back and on the sides is required between the heater and flammable structures and furniture. Fire protection within radiation perimeter Make...

 Open the catalog to page 2
BORGHOLM keramik Top-3

Capacity: Weight: Upper flue gas outlet: 15. Technical Data 7 kW 77 - 130 kg 150 mm Data for chimney properties calculation (at nominal heating capacity): Guarantee Shall any failure, malfunction, or surface defect occur on your heater within the guarantee period do never repair it by yourself. Aftersale service can be done only by the manufacturer or distributor. We guarantee the quality, function, and construction of the cooker for 2 years from the day of purchase: defects definitely occurred as a consequence of manufacturing defect will be remedied within short time at our cost under the condition...