Introduction
The Thermo Scientific Orion AQUAfast AQ3010 Turbidity Meter is a portable device designed for field measurements of turbidity in aqueous samples, adhering to ISO 7027 and DIN 27027 standards. It is suitable for applications such as water treatment and wastewater testing.

General Information
The AQ3010 package includes the turbidity meter, user guide, carrying case, calibration set, empty vials, silicone oil, a lint-free cloth, and a vial cleaning brush. Proper handling of vials is crucial to avoid measurement errors.

Meter Overview
The AQ3010 features a sample well, display, and keypad. The display shows turbidity readings and error messages, while the keypad includes keys for power, calibration, and measurement functions.

Battery Installation
Instructions for installing four AAA batteries are provided, emphasizing correct polarity and proper disposal of used batteries.

Turbidity Calibration
The meter comes pre-calibrated but includes primary standards for verification and recalibration. Calibration involves using a light shield cover and aligning vials for accurate measurements. The calibration standards include CAL 1 (800 NTU), CAL 2 (100 NTU), CAL 3 (20.0 NTU), and CAL 4 (0.02 NTU).

Turbidity Measurement
Procedures for preparing sample vials and conducting measurements are outlined, including single-shot and continuous measurement options. Proper technique involves using clean vials, aligning them correctly, and applying silicone oil to mask imperfections.

Routine Maintenance
Guidance on handling, cleaning, and caring for vials is provided to maintain measurement accuracy. Vials should be free of marks and scratches, cleaned with detergent, rinsed with distilled water, and can be coated with silicone oil.

Troubleshooting and Customer Service
The device performs self-diagnostics and displays error messages for issues like calibration errors or excessive stray light. Corrective actions include using fresh calibration standards and ensuring proper vial placement. The AQ3010 comes with a 3-year warranty against manufacturing defects, excluding improper maintenance or unauthorized modifications.

Specifications
The AQ3010 uses a nephelometric method with an infrared-emitting diode as the light source. It has a measurement range of 0 to 1000 NTU, with automatic range selection and a resolution varying from 0.01 NTU to 1 NTU depending on the range. The device is powered by four AAA batteries, providing over 1200 readings, and is housed in an IP67-rated waterproof enclosure.

Compliance and Certification
The AQ3010 is CE and cTUVus certified, complying with various safety and electromagnetic compatibility standards. It adheres to the European Union's WEEE Directive for electronic waste disposal.

Ordering Information
The AQ3010 package includes calibration standards, sample vials, a cleaning brush, silicone oil, and a carrying case. Replacement parts and accessories are available for order.

Conclusion
The AQ3010 turbidity meter is a reliable tool for measuring water clarity, essential for ensuring water quality in various applications. Proper use and maintenance are key to obtaining accurate and consistent results.
See more

Catalog excerpts

AQUAfast AQ3010 Turbidity Meter-1

Thermo Scientific Orion AQUAfast AQ3010 Turbidity Meter User Guide

 Open the catalog to page 1
AQUAfast AQ3010 Turbidity Meter-2

ROSS and the COIL trade dress are trademarks of Thermo Fisher Scientific Inc. US patent 6,793,787. AQUAfast, Cahn, ionplus, KNIpHE, No Cal, ORION, perpHect, PerpHecT, PerpHecTion, pHISA, pHuture, Pure Water, Sage, Sensing the Future, SensorLink, ROSS, ROSS Ultra, Sure-Flow, Titrator PLUS and TURBO2 are registered trademarks of Thermo Fisher. 1-888-pHAX-ION, A+, All in One, Aplus, AQUAsnap, AssuredAccuracy, AUTO-BAR, AUTO-CAL, AUTO DISPENSER, Auto-ID, AUTO-LOG, AUTO-READ, AUTO-STIR, Auto-Test, BOD AutoEZ, Cable-Free, CERTI-CAL, CISA, DataCOLLECT, DataPLUS, digital LogR, DirectCal, DuraProbe, Environmental...

 Open the catalog to page 2
AQUAfast AQ3010 Turbidity Meter-3

Table of Content Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 AQ3010 Meter Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Unpacking the Meter and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . 2 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Keys and Functions . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 3
AQUAfast AQ3010 Turbidity Meter-4

Turbidity Theory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Why Is It Important . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Measurement Principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Nephelometric Turbidity Units (NTU) . . . . . . . . . . . . . . . . . . . . . . . . 30 Indexing a Vial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 4
AQUAfast AQ3010 Turbidity Meter-5

General Information This user guide contains information on the preparation, operation and maintenance of the Thermo Scientific Orion AQUAfast® AQ3010 turbidity meter. This user guide provides both a step by step guide to help you operate the waterproof AQ3010 turbidity meter and serves as a handy reference guide. Follow the basic instructions contained in this user guide during the operation, care and maintenance of the meter. The safety protections provided by this equipment may be impaired if it is used in a manner not described in this user guide. It is recommended that all operators should...

 Open the catalog to page 5
AQUAfast AQ3010 Turbidity Meter-6

Unpacking the Meter and Accessories The list below indicates the items that you should find in your AQ3010 turbidity meter shipment. Item AQ3010 portable turbidity meter with 4 AAA batteries User guide Instrument carrying case Light shield cover Calibration set with 0.02, 20.0,100 and 800 NTU standards Empty calibration vials Empty sample vials Lint free cloth Vial cleaning brush Remove the AQ3010 turbidity meter from the carrying case. Carefully inspect all items to ensure that no visible damage has occurred during shipment. If the items you received do not match your order, please contact your...

 Open the catalog to page 6
AQUAfast AQ3010 Turbidity Meter-7

Figure 1 AQ3010 Turbidity Meter Components Sample Vial Alignment Mark Sample Well Liquid Crystal Display Thermo Scientific Orion AQUAfast AQ3010 Turbidity Meter User Guide

 Open the catalog to page 7
AQUAfast AQ3010 Turbidity Meter-8

Figure 2 Customized LCD with All Annunciators All the LCD segments and annunciators that can appear on the display are shown in Figure 2. The display is used for reporting the turbidity reading and to provide guidance for the operation of the instrument. In addition, the display has several other annunciators that are used to communicate error messages and provide user guidance. Calibration Standards Battery Indicator 14-segment Liquid Crystal Display Thermo Scientific Orion AQUAfast AQ3010 Turbidity Meter User Guide

 Open the catalog to page 8
AQUAfast AQ3010 Turbidity Meter-9

The keypad has five keys: ON/OFF, CAL, ▲, ▼ and READ/ENTER. Key Functions Powers on and off the meter. The meter automatically CAL shuts off 20 minutes after last key press to conserve the battery life. READ ENTER READ ENTER Initiates the calibration mode of the meter. When pressed, the meter is set to accept the first calibration standard. It is also used to exit the calibration mode if the user does not want to follow the complete calibration procedure. When in measurement mode, the READ/ENTER key is used to perform a measurement. CAL Single-shot measurements: When the key is pressed and released...

 Open the catalog to page 9
AQUAfast AQ3010 Turbidity Meter-10

Battery Installation Four AAA batteries are included in the carrying case. Note: Use caution when loosening the screws, as some of the screws may be tightly seated. 1. Use a Phillips screwdriver to loosen the four screws holding the battery cover. See Figure 4. These captive screws will remain attached to the battery cover. 2. Remove the battery cover. 3. Insert the batteries. Follow the diagram inside the cover for correct polarity. 4. Replace the battery cover in its original position and tighten the four screws removed earlier to secure the battery cover to the meter. 5. The meter is now ready...

 Open the catalog to page 10
AQUAfast AQ3010 Turbidity Meter-11

Calibration Overview Turbidity Calibration The AQ3010 turbidity meter was calibrated and tested prior to leaving the factory. The meter kit includes a set of prepared primary standards that can be used to verify the meter calibration daily and to recalibrate the meter, if required. Before measuring samples for the first time, verify the meter calibration with the prepared primary standards. The SDVB primary standards in the meter kit are in plastic bottles for improved precision and shelf life. Four vials are included and labeled for each standard level. The instrument includes a light shield...

 Open the catalog to page 11
AQUAfast AQ3010 Turbidity Meter-12

The four bottles of calibration standards supplied with your meter are more stable than Formazin, do not need to be shaken and have a shelf life of 12 months. If you use the supplied calibration standards to calibrate the instrument, review the expiration date (indicated on the bottle label) to ensure that the standards have not expired. Note: It is important that the calibration standards are not violently shaken or agitated because air entrapment in the fluid introduces an error factor during calibration which subsequently will lead to an inaccurate measurement. Also, do not store in freezing...

 Open the catalog to page 12

All Thermo Scientific catalogs and technical brochures

  1. Orion AQ3700

    4  Pages

  2. Orion AQ3070

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.