THEBEN LUXOR
20Pages

{{requestButtons}}

Catalog excerpts

THEBEN LUXOR - 1

english LUXOR Living comfort controller

Open the catalog to page 1
THEBEN LUXOR - 2

2 LUXOR SYSTEMS LUXOR LUXOR comfort control system with control, display and operation panel

Open the catalog to page 2
THEBEN LUXOR - 3

3 SYSTEMS LUXOR More comfort and safety thanks to 3 buttons at the front door: – Central OFF: Press one button and all lights are switch off, e. g. radio and windows as well. – Central ON: Press one button and hall, kitchen and living room lighting is switched on, e. g. if you are coming into the house during the winter half year. – Presence simulation: Protect your house from burglars by lighting your house as though you are there. SYSTEM Comfort system for heating, air conditioning and lighting in homes and small buildings with especially comfortable operation and room function display as...

Open the catalog to page 3
THEBEN LUXOR - 4

4 LUXOR SYSTEMS LUXOR Centrally control and monitor building functions – easy Date Time Display central functions Selection option screen page as well as manual/automatic Setting buttons

Open the catalog to page 4
THEBEN LUXOR - 5

5 SYSTEMS LUXOR SHUTTERS LUXOR 426 automatically controls shutters at dawn and dusk thanks to the astronomical program. The offset with ± 120 min is practical for individual adjustment as well as the "not before" function, which prevents shutters from opening at 5:00am in the summer. BLINDS As soon as the sun shines on the facade, the blinds automatically adjust to the desired lamella position. Light sensors on the facade follow the position of the sun. Manual control is central or possible at any time depending on the facade. AWNING The LUXOR weather station retracts the awning when there...

Open the catalog to page 5
THEBEN LUXOR - 6

6 LUXOR SYSTEMS LUXOR Manual control a Control shutters s Control awnings d Weather station for wind, light, temperature and rain (optional) Manual control, astronomical or weather-dependant control, weather data display LUXOR 426 Central South facade Single button e.g. for balcony door SOUTH WEST LUXOR 408 S LUXOR 411 Perfect automatic sun protection and shutter control

Open the catalog to page 6
THEBEN LUXOR - 7

7 SYSTEMS LUXOR a Switch/dim light s Time controlled staircase/hallway light 1–5 min/1 h d Panic button switches all outside lights and closes shutters and balcony doors f Regular program controlled ventilation g Individual room control with program controlled temperature reduction h Central OFF button j Central ON/lighting setting button k Presence simulation button, e.g. during holiday additional temperature controllers s d f g g a h j k Energy-saving control of lighting, heating and ventilation

Open the catalog to page 7
THEBEN LUXOR - 8

8 httpAdditional technical data at: www.theben.de/product/ Article number With display SYSTEMS LUXOR LUXOR 426 Description LUXOR 426 ¡ Central display and control unit for the LUXOR system ¡ Time, weekday, date as well as central and automatic functions are displayed ¡ Current weather conditions can be displayed as well as min/max values ¡ Display with back-lighting ¡ Favourite sites can be selected from 6 pages ¡ 8 channel time switch ¡ For control of any outputs in LUXOR system, e. g. shutters, blinds, awnings, ventilation, lighting control as well as pond or recircultaion pumps, ¡...

Open the catalog to page 8
THEBEN LUXOR - 9

9 httpAdditional technical data at: www.theben.de/product/ Article number SYSTEMS With display Scale drawings LUXOR 426 128 4 18,1 45,6 93,4 Connection example LUXOR 426 U COM + – – + (N) (L) C1 C2 C3 I4 I4 NLL C4 N L I1 I2 I3 LUXOR 400 LUXOR 405 P S C4 ** * ** G1 COM M + – L C1 C2 C2 C3 C3 N L I3 I4 N L M M I2 LUXOR 408 S I1 COM + – D1 D2 N L L L LS I1 I2 S1 S2 COM LUXOR 426 + – * L L C1 COM + – LUXOR 412 + – N L LUXOR 411 C2 C3 =

Open the catalog to page 9
THEBEN LUXOR - 10

10 httpAdditional technical data at: www.theben.de/product/ Article number Shutter control SYSTEMS LUXOR LUXOR shutter control LUXOR 408 S LUXOR 409 S Description Common functions ¡ For controlling shutters, awnings or blinds ¡ Separate control of 4 shutters with UP/ DOWN/STOP ¡ Manual switch on device ¡ LEDs to display ¡ Controllable via standard shutter sensor ¡ Upgradeable for up to 16 LUXOR modules ¡ LUXOR modules are connected via 2-wire bus cable (COM bus) ¡ Setting option for panic function (via LUXOR 400) ¡ Storable intermediate position and turn for shading and ventilation LUXOR...

Open the catalog to page 10
THEBEN LUXOR - 11

11 httpAdditional technical data at: www.theben.de/product/ Article number SYSTEMS Shutter control Technical data LUXOR 408 S LUXOR 409 S Operating voltage 230 V AC Frequency 50 Hz Width 4 modules Power consumption 4 VA Installation type DIN-rail Number of channels 4 Type of contact NO contact Connecting cable 230 V phase-independent supply cable, cable length max. 100 m Connection for COM Any cross-section/max. length 100 m Switching capacity 6 A (at 250 V AC, cos ö = 1) Function channels for shutter, blind and awning control Ambient temperature –10 °C … +50 °C Protection rating IP 20...

Open the catalog to page 11
THEBEN LUXOR - 12

12 httpAdditional technical data at: www.theben.de/product/ Article number Weather sensors SYSTEMS LUXOR LUXOR sensor technology LUXOR 411 LUXOR 412 LUXOR 413 Description LUXOR 411 ¡ Sensor module ¡ For controlling awnings, shutters and blinds in combination with LUXOR 412 and/or 413 and integrated light sensors ¡ Setting threshold values on device ¡ LEDs to display ¡ Max. input cable length of sensor line is 100 m ¡ LUXOR modules are connected via 2-wire bus cable (COM bus) LUXOR 412 ¡ Weather sensor ¡ For controlling awnings, shutters and blinds depending on rain, wind velocity,...

Open the catalog to page 12
THEBEN LUXOR - 13

13 httpAdditional technical data at: www.theben.de/product/ Article number SYSTEMS Weather sensors Technical data LUXOR 411 LUXOR 412 LUXOR 413 Operating voltage 230 V AC COM-Bus 24 V DC Frequency 50 Hz – Width 4 modules – Power consumption 5.5 VA – Installation type DIN-rail Wall or mast installation Connection for COM Any cross-section/max. length 100 m Setting range twilight value 1–100 lx – Setting range sun protection 1000–100000 lx – Measuring range wind velocity 2–20 m/s Measuring range temperature +0 °C … +60 °C – Ambient temperature –10 °C … +50 °C –20 °C … +55 °C Protection rating...

Open the catalog to page 13