Fire-Rated Hose Stream Tested Positive Pressure Tested Impacted Rated UL Classified & Labeled FIRE-RATED, IMPACT SAFETY-RATED WIRED GLASS WITH SURFACE-APPLIED FILM WireLite® NT is a 17/64” (6.8 mm) thick glazing material composed of wired glass and a fire-rated surface-applied film. WireLite NT is listed for use in doors, sidelites, transoms and borrowed lites. ▲ FIRE RATING 20 - 90 MINUTES • Protects from fire and impact on both sides of the glass • Available as an insulated glass unit • Available in Diamond Clear, 3/4” pattern (19 mm) and Georgian Clear, 1/2” pattern (12.7 mm) • Fire-rated for up to 90 minutes with required hose stream test • Impact safety-rated-meets ANSI Z97.1 and CPSC 16 CFR1201 (Cat. I and II) • Fits in Fireframes® Designer Series from TGP, or standard fire-rated frames • Withstands thermal shock • May be lightly sandblasted or etched on the unfilmed side without affecting fire rating NOTE: This product is not a barrier to radiant heat, as it does not meet test standards ASTM E119 or UL 263. If your jurisdiction requires a “barrier to heat” product, please contact TGP regarding Pilkington Pyrostop®. Classified and labeled by Underwriters Laboratories, Inc. ® and Underwriters Laboratories of Canada. File number for labeled fire-rated assemblies is R13377. Tests performed in accordance with: TOP NFPA 80 NFPA 252 NFPA 257 TECHNICAL GLASS PRODUCTS*
Open the catalog to page 1WireLitei MAXIMUM EXPOSED AREA 45 min. DOORS (non-temp rise) OTHER THAN DOORS RATING ASSEMBLY MAX. EXPOSED AREA MAX W‘D™POSED SIZES WHEN GLAZED WITH PEMKO FG3000™ 45 min. WOOD DOOR (non-temp rise) Note: Individual lite sizes cannot exceed “Max. Exposed Area" shown above. SURFACE FINISH Diamond Georgian TECHNICAL CUSS PRODUCTS' ALLEGION fireglass.com
Open the catalog to page 2WireLitei general characteristics Detail based on use of Fireframes Designer Series narrow profile framing Glazing Thickness: APPROX. VISIBLE TRANSMISSION: 77% FIRE RATING: 20 to 90 minutes IMPACT SAFETY RATING: Meets ANSI Z97.1 and CPSC Each piece of WireLite NT shall be permanently labeled with the WireLite NT logo, UL logo and fire rating. WireLite NT shall be glazed into the appropriate fire-rated framing with an approved glazing compound (pure silicone, closed cell PVC tape, or DAP 33 putty) as supplied by the installer. For sizes larger than 1,296 in2 (.84 m2) or 54” (1.37 m) in one dimension...
Open the catalog to page 33 Pages
2 Pages
3 Pages
3 Pages
2 Pages
2 Pages
1 Page
1 Page
2 Pages
2 Pages
58 Pages
12 Pages