Firelite IGU - 1

HOSE STREAM TESTED ENERGY EFFICIENT POSITIVE PRESSURE TESTED FIRE-RATED OR FIRE/IMPACT SAFETY-RATED INSULATED GLASS UNITS (IGU) FireLite® IGU is composed of FireLite products and tempered or annealed float glass. It is listed for use in fire-rated applications with ratings from 20 minutes to 3 hours (must be specified with either FireLite NT or FireLite Plus® for 3 hour rating). Trusted for over 20 years, the FireLite family of products now feature ultraHD® Technology for superior color and surface quality. Now with ultraHD® Technology for improved surface quality, clarity and color Available in two surface finishes for clear viewing, Standard Grade and Premium Grade Clear and wireless Fire-rated for up to 3 hours with required hose stream test Impact safety-rated version meets ANSI Z97.1 and CPSC 16CFR1201 (Cat. I and II) Large sizes available Typical 1" thickness fits in Fireframes® Designer Series or Fireframes Hardwood Series from TGP, or standard fire-rated frames (variable thicknesses available) • Available incorporating a variety of glass products, including (but not limited to): • Tinted • Low-E • Glass • Art Reflective • One-Way Mirror • Lead Glass (X-Ray) • May be lightly sandblasted or etched on one side without affecting fire rating • Passes positive pressure test standards UL 10C • 10-year limited warranty • Stainless steel spacers • Decorative films approved by TGP Note: This product is not a barrier to radiant heat, as it does not meet test standards ASTM E-119 or UL 263. If your jurisdiction requires a “barrier to heat” product, please contact Technical Glass Products regarding Pilkington Pyrostop®. LISTINGS Classified and labeled by Underwriters Laboratories, Inc.® and Underwriters Laboratories of Canada. File number for labeled fire-rated assemblies is R13377. Tests performed in accordance with UL 9, UL 10B, UL 10C, ASTM E2074, CSFM 43.7, NFPA 80, NFPA 252, NFPA 257, CAN4 S-104, and CAN4 S-106. Approved for use in Los Angeles: LARR 25798. GENERAL CHARACTERISTICS SEAL Dual-seal polysulfide units with breather tubes U-VALUE Similar to standard insulating units with a make-up of: 1/4" float glass - 1/2" air space - 1/4" float glass (6.4 mm float glass - 12.7 mm air space - 6.4 mm float glass) Summer U-Value: Approximately .55* Winter U-Value: Approximately .49* *U-values increase with use of high performance float glass products. STC RATING 3/16" (5 mm) FireLite 3/16" (5 mm) FireLite NT 5/16" (8 mm) FireLite Plus 9/16" (14.23 mm) air space 9/16" (14.23 mm) air space 9/16" (14.23 mm) air space 1/4" (6.4 mm) float glass 1/4" (6.4 mm) float glass 1/4" (6.4 mm) float glass ** Values were achieved with these s

Open the catalog to page 1
Firelite IGU - 2

DOORS (non-temp rise) MAX. WIDTH OF EXPOSED GLAZING MAX. HEIGHT OF EXPOSED GLAZING DOORS (non-temp rise) DOORS (temp rise) OTHER THAN DOORS OTHER THAN DOORS DOORS (temp rise) Check with frame manufacturer for maximum tested glass sizes and required stop height. Note: Individual lite sizes cannot exceed "Max. Exposed Area" shown above. SURFACE FINISH MAX. SHEET SIZE SPECIFICATIONS Due to the great variety of possible make-ups with FireLite IGU, please call Technical Glass Products at 800.426.0279 for assistance when preparing specifications. Additional specification information is available...

Open the catalog to page 2

All TGP catalogs and technical brochures

  1. FireLite NT

    3 Pages

  2. FireLite

    2 Pages

  3. LX–57B

    1 Pages

  4. LX PREMIUM

    1 Pages

Archived catalogs

  1. Handbook

    12 Pages