Catalog excerpts
HOSE STREAM TESTED ENERGY EFFICIENT POSITIVE PRESSURE TESTED FIRE-RATED OR FIRE/IMPACT SAFETY-RATED INSULATED GLASS UNITS (IGU) FireLite® IGU is composed of FireLite products and tempered or annealed float glass. It is listed for use in fire-rated applications with ratings from 20 minutes to 3 hours (must be specified with either FireLite NT or FireLite Plus® for 3 hour rating). Trusted for over 20 years, the FireLite family of products now feature ultraHD® Technology for superior color and surface quality. Now with ultraHD® Technology for improved surface quality, clarity and color Available in two surface finishes for clear viewing, Standard Grade and Premium Grade Clear and wireless Fire-rated for up to 3 hours with required hose stream test Impact safety-rated version meets ANSI Z97.1 and CPSC 16CFR1201 (Cat. I and II) Large sizes available Typical 1" thickness fits in Fireframes® Designer Series or Fireframes Hardwood Series from TGP, or standard fire-rated frames (variable thicknesses available) • Available incorporating a variety of glass products, including (but not limited to): • Tinted • Low-E • Glass • Art Reflective • One-Way Mirror • Lead Glass (X-Ray) • May be lightly sandblasted or etched on one side without affecting fire rating • Passes positive pressure test standards UL 10C • 10-year limited warranty • Stainless steel spacers • Decorative films approved by TGP Note: This product is not a barrier to radiant heat, as it does not meet test standards ASTM E-119 or UL 263. If your jurisdiction requires a “barrier to heat” product, please contact Technical Glass Products regarding Pilkington Pyrostop®. LISTINGS Classified and labeled by Underwriters Laboratories, Inc.® and Underwriters Laboratories of Canada. File number for labeled fire-rated assemblies is R13377. Tests performed in accordance with UL 9, UL 10B, UL 10C, ASTM E2074, CSFM 43.7, NFPA 80, NFPA 252, NFPA 257, CAN4 S-104, and CAN4 S-106. Approved for use in Los Angeles: LARR 25798. GENERAL CHARACTERISTICS SEAL Dual-seal polysulfide units with breather tubes U-VALUE Similar to standard insulating units with a make-up of: 1/4" float glass - 1/2" air space - 1/4" float glass (6.4 mm float glass - 12.7 mm air space - 6.4 mm float glass) Summer U-Value: Approximately .55* Winter U-Value: Approximately .49* *U-values increase with use of high performance float glass products. STC RATING 3/16" (5 mm) FireLite 3/16" (5 mm) FireLite NT 5/16" (8 mm) FireLite Plus 9/16" (14.23 mm) air space 9/16" (14.23 mm) air space 9/16" (14.23 mm) air space 1/4" (6.4 mm) float glass 1/4" (6.4 mm) float glass 1/4" (6.4 mm) float glass ** Values were achieved with these s
Open the catalog to page 1DOORS (non-temp rise) MAX. WIDTH OF EXPOSED GLAZING MAX. HEIGHT OF EXPOSED GLAZING DOORS (non-temp rise) DOORS (temp rise) OTHER THAN DOORS OTHER THAN DOORS DOORS (temp rise) Check with frame manufacturer for maximum tested glass sizes and required stop height. Note: Individual lite sizes cannot exceed "Max. Exposed Area" shown above. SURFACE FINISH MAX. SHEET SIZE SPECIFICATIONS Due to the great variety of possible make-ups with FireLite IGU, please call Technical Glass Products at 800.426.0279 for assistance when preparing specifications. Additional specification information is available...
Open the catalog to page 2All TGP catalogs and technical brochures
-
Fireframes Aluminum Series
3 Pages
-
FireLite PLUS WS
2 Pages
-
FireLite NT
3 Pages
-
FireLite PLUS
3 Pages
-
FireLite
2 Pages
-
LX–57B
1 Pages
-
LX PREMIUM
1 Pages
-
Pilkington Pyrostop
2 Pages
-
Fireglass®20
2 Pages
-
Architectural Look Book
58 Pages
Archived catalogs
-
Handbook
12 Pages