Catalog excerpts
Light Commercial & Residential MULTI-SPLIT Multi-split Overview Multi-split Outdoor Units Lineup 2-unit to 8-unit Multi-split Connectable Indoor Units Simultaneous Multi-split Connectable Indoor Units Feature Summary Refrigerant type R32 models Refrigerant type R410A models M-012 2-unit to 5-unit Multi-split M-018 Simultaneous Multi-split Twin/Triple ––––––––––––––––––––––––––––––––––––––––––––––– M-022 2-unit to 5-unit Multi-split Indoor Units Specifications ––––––––––––––––––––––––––––––––––––––––––––––– M-026 2-unit to 5-unit Multi-split Combination Table 6-unit to 8-unit Multi-split M-014 6-unit Multi-split M-016 8-unit Multi-split Simultaneous Multi-split M-020 Simultaneous Multi-split Twin/Triple/Double Twin ––––––––––––––––––––––––––––––––––––––––––––––– M-024 6-unit to 8-unit Multi-split Indoor Units Specifications ––––––––––––––––––––––––––––––––––––––––––––––– M-036 6-unit to 8-unit Multi-split Combination Table Control several indoor units wi
Open the catalog to page 1Multi-split Overview Space-saving Multi-split outdoor units can connect up to 8 indoor units in multiple rooms. New refrigerant R32 models are additionally added. Multi-split type can be introduced in various situations like in homes, in offices and stores to provide environment-friendly comfort. 2-unit to 8-unit Multi-split 2-unit to 8-unit Multi-split types units are recommended for situations that require air conditioning in multiple rooms such as in family house or offices. Between 2 to 8 indoor units can be connected and individually operated. A variation of individual and central...
Open the catalog to page 2Multi-split Outdoor Units Lineup FUJITSU GENERAL (Euro) GmbH participates in the ECP program for VRF. Check ongoing validity of certificate: www.eurovent-certification.com *Models so marked are not ECC certified. Class Cooling rated capacity(kW) AOYG45LBT8* Branch box Separation tube Simultaneous Multi-split Single phase Single phase Twin/Triple/ Double Twin 3 phase Note: 1. 2-unit Multi-split: Connectable indoor units are 2 units. AOYG14KBTA2: Total capacity of indoor units connected must be between 4.0 kW and 6.0 kW. AOYG18KBTA2: Total capacity of indoor units connected must be between...
Open the catalog to page 32-unit to 8-unit Multi-split Connectable Indoor Units Model name Model name Multi-split Type Outdoor Unit Multi-split Type Outdoor Unit Cooling Heating Indoor Unit Cooling Heating Indoor Unit
Open the catalog to page 4Simultaneous Multi-split Connectable Indoor Units Model name Model name Simultaneous Multi-split Outdoor Unit Cooling Heating Cooling Heating Double Twin Indoor Unit Indoor Unit Double Twin
Open the catalog to page 5Space-saving installation Multiple indoor units can be connected to 1 outdoor unit, and long piping connection is also possible. Compared with single type, the outdoor unit can be installed in various places to realize the space-saving installation. Compact design Easy evacuation Compared with single type, the outdoor unit can be installed in various places to realize the space-saving installation. All connected pipes and indoor units can be evacuated quickly via our centralized valve method. Requires evacuation only once. High energy saving All models achieve high energy efficiency rank of...
Open the catalog to page 6Front view Pitch of bolts for installation Front view Side view Total / Each Between Outdoor Unit m Max. Height Difference and Each Indoor Units. Between Indoor Units. Cooling Operating Range °CDB Heating Type (Global Warming Potential) Refrigerant Charge kg(CO2eq-T) Front view Side view Front view Bottom view Side view (Valve part) Bottom view Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling/Heating Side view (Valve part) Bottom view Side view (Valve part) Bottom view Total / Each Between Outdoor Unit m Max. Height Difference and Each Indoor Units. Between Indoor...
Open the catalog to page 7AOYG45LBLA6 Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling/Heating Rated Capacity (Min. - Max.) EER COP Sound Pressure Level (High) Sound Power Level (High) Net Dimensions H × W × D Weight Connection Pipe Diameter Max. Pipe Length Liquid Gas Total / Each Between Outdoor Unit m Max. Height Difference and Each Indoor Units. Between Indoor Units. Cooling Operating Range °CDB Heating Type (Global Warming Potential) Refrigerant Charge kg(CO2eq-T) Wide range of indoor units with various models 4 types / 16 models are lined up in the capacity range from 2.0 kW to...
Open the catalog to page 8Specifications (Outdoor unit/Branch box) Outdoor Unit Model Name Max. Pipe Length Max. Height Difference (O.U ~ I.U) Refrigerant Branch Box Model Name W A mm kg(Ibs) Liquid Gas Method Connection pipe diameter High seasonal efficiency EER Pipe length: 5 m (Outdoor unit - Branch box), 3 m (Branch box - Indoor unit) Height difference : 0 m Branch Box : UTP-PY03A (3 zones type) Decrease capacity Increase capacity Branch Box : UTP-PY02A (2 zones type) Decrease capacity Increase capacity Refrigerant control by branch box Every room meets the set point most quickly and comfortably by optimized...