INSTALLATION Notes on installation NOTES ON INSTALLATION The SISTEM-AIR piping is made up of antistatic, self-extinguishing PVC, built to guarantee a perfect combination between piping and connections. In parti-cular, the piping is: Self-extinguishing, antistatic, calibrated, with thickness of between 2.2 mm for 0 50 mm diameter and 3 mm for 0 63/80/100 mm dia-meter. Ail connections of the piping network are glued together with spcial self-adhesive cold glue. Its particular technical characteristics ensure that the glued parts stick perfectly. The correct setting and installation of the piping network ensures that the System works properly and this is why it is undoubtedly considered the most im魭portant stage for obtaining optimum running of the centralised vacuum System. We advise ail operators to stick rigidly to the advice provided in order to simplify the oprations for compiling the piping network and ensure optimum running of the System, thus keeping a steady performance over time. Cut of the piping and proper joining of connectors In order to cut the pipes properly, use ONLY cylindrical pipe cutting tool. The pipes should ALWAYS be placed correctly: they should al-ways be inserted till it reaches the ledge. PROPER equipment RIGHT cut and RIGHT positioning Examples of WRONG pipe cutting UNSUITABLE tool for cutting. Example ofcut made with an unsuitabletool. www.sistemair.it rif. 01-2008 ENG
Open the catalog to page 1Notes on installation INSTALLATION central vacuum Systems Gluing the piping to the connectors The stage of gluing the piping to the connectors is without a doubt the most dlicate stage of the central vacuum System because if it is not carried out properly, there could be a loss in flow of the System. Overtime, this would cause s魩dimentation of the vacuumed product inside the piping located into chase. The opration is carried out properly by spreading the glue only on the piping or on the maie part of the connecter. This ensures that when the piping is fitted to the connecter, any excess...
Open the catalog to page 2INSTALLATION Notes on installation Direction of suction For the branching of more inlet valve points, use the female female 45° drivation connectors, or maie female 45° drivation. This connector is used both for the d驩rivation of a socket pipe line on the same floor and for the stable implementation of upright pipes on several floors. It is essential that the dͩrivation is always installed correctly in relation to the system's direction of suction (see figure). The incorrect installation of the drivation will inevitably blockthe System. Direction of suction o the central vacuum unit CORRECT...
Open the catalog to page 3Notes on installation INSTALLATION ^ central vacuum Systems Standard mounting plate with straight connector Standard mounting plate with elbow connector The standard mounting plate with elbow connector, only 7 cm thick, can be installe! in any kind of wall. The mounting plate is fitted with an elbow connector that rottes at 360° in order to position itself to the connec颭tor, wherever it may be. IMPORTANT: the mounting plate should always be installͩe! flat into the wall. The standard mounting plate with straight connector should be regarded as a suitable part for ail those unusual jobs...
Open the catalog to page 4INSTALLATION Notes on installation EXAMPLE OF BASE CONNECTIONS Example of base connection to install the inlet valve. ARTICLE PRODUCT DESCRIPTION 1 0 50 mm thick PVC pipe 2,2 2 0 50 mm 45° F.F. PVC drivation 3 0 50 mm 45° MF PVC elbow connecter 4 Standard mounting plate, straight connecter with cover 5 2x1 25 m pre-wired conduit 5 2x1 50 m pre-wired conduit 2x1 100 m pre-wired conduit EXAMPLE OF CONNECTION TO INLET VALVES Example of connection to inlet valves. Rectangular mounting plate Clamps on the wail Dcorative plaque (not providedj 100 B www.sistemair.it rif. 01-2008 ENG
Open the catalog to page 5Notes on installation INSTALLATION central vacuum Systems EXAMPLE OF DOMESTIC SYSTEM ONTHREE FLOORS Example of sized System to be used by only one operator at the most on each floor (NB: ail the Systems in the domestic range can only have one operator at a time). The System in question is created in a domestic structure on three floors. The piping will be exclusively 0 50 mm both as regards the upright pipe and the distribution on each floor. The position of the vacuum openings should take into considration the fact that the hose used for cleaning is 7 mtres: it is therefore important when...
Open the catalog to page 6Installation area The SISTEM-AIR installation material in PVC is suitable for ail kinds of central va-cuum Systems and can be divided into four product catgories: - Grey 0 50 mm, 2.2 mm thick. 0 63 - 0 80 - 0100mm, 3.0 mm thick piping - Grey 0 50 mm, 2.2 mm thick. 0 63 - 0 80 - 0100mm, 3.0 mm thick connec-tors - Grey conduit with 2,1 mm2 conductors inserted. - Spcial self-adhesive glue to join the piping to the connectors. Particular characteristics of the product Quality, sturdy system products that meet with the strictest safety and quality homologations and certifications that satisfy...
Open the catalog to page 7Installation materials INSTALLATION central vacuum Systems SISTEM CASE Sistem Case is a new case to build in Sistem Air central units, especially developed to save space and to aesthetically integrate the vacuum unit in the wall. It is realized in strong zinc-coated steel and thanks to its telescopic structure it fits any MINI and MEDIA Sistem Air vacuum unit. With a single codeyou can match diffrent installation needs. The cover, made of plastic material in aluminium colour, has a futuristic and at the same time simple design. It is available in two diffrent versions, depending on the kind...
Open the catalog to page 8INSTALLATION Installation materials INSTALLATION MATERIAL Rigid PVC piping and connectors especially designed for central vacuum Systems with a view to create a perfect fit between the piping and connectors; only 45° connectors are provided to allowfor the best air flow possible without creating the possibility of the System blocking. NB: It is extremely important that the rigid PVC piping is eut using the appropriate tool (pipe cutter) and that the hold between the joints is guaranteed by using the spͩcial SISTEM-AIR glue in abundance, spreading it on the maie and never on the female...