Dry system tchnoclima
12Pages

{{requestButtons}}

Catalog excerpts

Dry system tchnoclima - 1

P R O D U C T S CATALOGUE FOR AGRICULTURE AND POULTRY

Open the catalog to page 1
Dry system tchnoclima - 2

SUSPENDED AGRICULTURAL HEATERS CERTIFIED IN ACCORDANCE WITH: GAS DIRECTIVE 90/396/CEE LOW TENSION DIRECTIVE 73/23/CEE MACHINE DIRECTIVE 89/392/CEE ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 89/336/CEE Warm air heaters either for direct or tubing air distribution, working with light oil or gas burner. Stainless steel combustion chamber and heat exchanger completely in stainless steel AISI 430, either with high performance axial or centrifugal fans, electronic control and safety system Cabinet heater robustly constructed formed by galvanized pre-coated steel panels fitted with radiant sheet...

Open the catalog to page 2
Dry system tchnoclima - 3

OVERALL DIMENSIONS With axial fan Model AGRI-P AGRI-P AGRI-P AGRI-P AGRI-P AGRI-P/R AGRI-P/R AGRI-P/R AGRI-P/R 240 *Heaters equipped with burner and circular duct panel. TECHNICAL SPECIFICATIONS Unit Model Heating capacity input Heating capacity OUTPUT Air flow rate Electrical motor Electrical supply Thermic performance certified

Open the catalog to page 3
Dry system tchnoclima - 4

MOBILE AGRICULTURAL HEATERS CERTIFIED IN ACCORDANCE WITH: GAS DIRECTIVE 90/396/CEE LOW TENSION DIRECTIVE 73/23/CEE MACHINE DIRECTIVE 89/392/CEE ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 89/336/CEE Warm air heaters either for direct or tubing air distribution, working with light oil or gas burner stainless steel combustion chamber and heat exchanger completely in stainless steel AISI 430, either with high performance axial or centrifugal fans, electronic control and safety system. Cabinet heater robustly constructed with galvanized pre-coated steel panels fitted with radiant sheet insulation....

Open the catalog to page 4
Dry system tchnoclima - 5

OVERALL DIMENSIONS With axial fan Model AGRI-C AGRI-C AGRI-C AGRI-C AGRI-C AGRI-C/R AGRI-C/R AGRI-C/R AGRI-C/R 240 * Heaters equipped with burner and four ways plenum with fins TECHNICAL SPECIFICATIONS Unit Model Heating capacity input Heating capacity OUTPUT Air flow rate Electrical motor Electrical supply Thermic performance certified

Open the catalog to page 5
Dry system tchnoclima - 6

GROUND HEATING WARM AIR HEATERS CERTIFIED IN ACCORDANCE WITH: GAS DIRECTIVE 90/396/CEE LOW TENSION DIRECTIVE 73/23/CEE MACHINE DIRECTIVE 89/392/CEE ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 89/336/CEE High efficiency warm air heater TC Down Flow series vertical version with gas or diesel burner provides warm air to be supplied mainly to greenhouse structures, but also in all cases where diffusion through an air-to-ground distributing device is required. The equipment consist mainly of an isolated cabinet receiving the air flow produced by the ventilator group. The cabinet contains a...

Open the catalog to page 6
Dry system tchnoclima - 7

OVERALL DIMENSIONS TECHNICAL SPECIFICATIONS Model Heating capacity imput Heating capacity output Usefull static pressure Electric motor Circular outlet diameter On request Thermic performance certified

Open the catalog to page 7
Dry system tchnoclima - 8

GROUND HEATING WARM AIR HEATERS CERTIFIED IN ACCORDANCE WITH: GAS DIRECTIVE 90/396/CEE LOW TENSION DIRECTIVE 73/23/CEE MACHINE DIRECTIVE 89/392/CEE ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 89/336/CEE High efficiency warm air heater TCO Down Flow series horizontal version with gas or diesel burner provides warm air to be supplied mainly to greenhouse structures, but also in all cases where diffusion through an airto-ground distributing device is required. The equipment consist mainly of an isolated cabinet receiving the air flow produced by the ventilator group. The cabinet contains a...

Open the catalog to page 8
Dry system tchnoclima - 9

OVERALL DIMENSIONS TECHNICAL SPECIFICATIONS Modello Heating capacity imput Usefull static pressure Electric motor Circular outlet diameter Heating capacity output Air flow rate Thermic performance certified

Open the catalog to page 9
Dry system tchnoclima - 10

RE-CIRCULATING WARM AIR HEATER CERTIFIED IN ACCORDANCE WITH: GAS DIRECTIVE 90/396/CEE LOW TENSION DIRECTIVE 73/23/CEE MACHINE DIRECTIVE 89/392/CEE ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 89/336/CEE Direct fired air heaters with 100% thermal efficiency, special atmospheric gas burner anti-dust working either with methane, propane or butane gas, hot surface ignition and flame control by ionisation, combustion chamber aluminium steel plate preventing high temperature and oxidation, high pressure radial fan for the air diffusion, external casing made by pre-painted galvanized steel with IP44...

Open the catalog to page 10
Dry system tchnoclima - 11

OVERALL DIMENSIONS Overall dimensions mm Lenght Width 705 Air recirculation plenum with damper, for the total or partial environment air inlet, even in case of outside istallation of the unit. It permit fuel saving up to 30%! TECHNICAL SPECIFICATIONS Temperature deviation Model Heating capacity ouput Air flow rate (+15 °C) Monophase electric supply

Open the catalog to page 11
Dry system tchnoclima - 12

Unlike the traditional air heating via an intermediate fluid (WET) using water as vector fluid, the innovative direct exchange air heating technology (DRY), uses air as the vector fluid, producing a concrete reduction in operating costs, as well as tangibly lowering the system costs. The most important feature of this system is that the produced energy, is directly and immediately transferred to the room to be treated, thereby substantially improving and partially avoiding the inefficient transformation stages. Therefore, with the same power input - also thanks to the absence of thermal...