ISOLMANT SPECIAL UNDERSCREED INSULATION Essential product specific for underscreed impact sound in double layer solutions with finishing value ranging between 4 and 7 cm. WHAT IS ISOLMANT SPECIAL? SPECIFIC APPLICATIONS Resilient layer in second-generation Isolmant polyethylene with embossed and screen-printed upper side, featured by a better and calibrated quality of the polyethylene cellulation. Thanks to its intrinsic quality and physical properties, this product ensures long-term performance. It provides excellent impact sound and airborne insulation for horizontal partitions. 3 mm, 5 mm, 10 mm and 15 mm thickness available. Isolmant Special is specific for floating screeds as provided by UNI 11516:2013 standards with any type of slab. This product is recommended for applications under a finishing screed (double layer solution), it requires a finishing screed at least 4 cm thick (for 3- 5 mm Isolmant Special) and at least 7 cm thick (for 10 -15 mm Special). In case of disjointing a floating screed from perimeter walls, it is recommended not to turn Isolmant Special upside down but to use Isolmant Fascia Perimetrale. Install Isolmant Special with the embossed and screenprinted side facing upwards. Thicknesses available: MINIMUM ENVIRONMENTAL CRITERIA All our products with the “Guaranteed Green Planet” logo are compliant with the sustainability criteria of the most important environmental protocols and certified according to the major national and international standards. Technical Data Sheet > ISOLMANT SPECIAL Impact sound | Underscreed insulation
Open the catalog to page 1ISOLMANT SPECIAL > GREEN PLANET GREEN FEATURES OF ISOLMANT SPECIAL • Volatile Organic Compounds free(VOC A+). • German Eco-label certification Blue Angel. • Manufactured with low environmental impact. • Contributes to achieve credits for the environmental certification of a building according to LEED or ITACA standards. Complies with the requirements defined by the Italian CAM Edilizia for acoustic and thermal insulation materials regarding the request for high acoustic insulation performance, the percentage of recycled material and the absence of hazardous substances. Green Planet is our sustainable...
Open the catalog to page 2ISOLMANT SPECIAL > ADVANTAGES • Excellent acoustic impact sound and airborne insulation. • Suitable for use in both renovation and new construction. • For special building needs where increased strength is required, it is available on request with a special anti-tearing protective fabric. • Product with overlaps (10 mm and 15 mm only). • Easy to trim: can be easily cut with a utility knife or box cutter. • Low thermal conductivity. • Unalterable over time. • Unlimited durability. • Contact with water does not affect performance or characteristics. • Impervious to mould or insects. Technical Data...
Open the catalog to page 3ISOLMANT SPECIAL > TECHNICAL SPECIFICATIONS > To be installed with the Isolmant embossed and screen-printed side facing upwards. NOMINAL THICKNESS: DYNAMIC STIFFNESS: IMPACT SOUND INSULATION: "IN SITU" IMPACT SOUND INSULATION: COMPRESSION CLASS: CONDUCTIVITY: THERMAL RESISTANCE: SPECIFIC HEAT CAPACITY: VAPOUR RESISTANCE: VOC A+ (7) Etichetta ecologica Blue Angel (8) EMISSION OF VOLATILE ORGANIC COMPOUNDS: Harmonised standards for CE marking are NOT currently available for acoustic insulation products. This means that Isolmant products are currently NOT subject to CE marking, nor to the drawing...
Open the catalog to page 4ISOLMANT SPECIAL > INSTALLATION TESTS RESIDENTIAL UNITS IN MODENA (MO) Supporting screed Resilient material Isolmant SPECIAL Levelling Screed Lightweight concrete Structural slab Total thickness Measured curve Curva sperimentale Impact sound | Underscreed insulation Technical Data Sheet > ISOLMANT SPECIAL
Open the catalog to page 5ISOLMANT SPECIAL > INSTALLATION INSTALLING FASCIA TAGLIAMURO Before installing all the partitions, Isolmant Fascia Tagliamuro must be laid. This high density,reticulated polyethylene foam accessory is specifically designed to disjoint partitions and slabs, thereby helping to reduce the structural sound transmission from the walls to the slab. This product is available in different thicknesses and densities depending on the weight of the partitions (Fig.A) DISJOINTING OF REINFORCED CONCRETE STRUCTURES In the presence of stairwells, elevator compartments and pillars (even if contained within the...
Open the catalog to page 6ISOLMANT SPECIAL > INSTALLATION INSTALLING FASCIA PERIMETRALE To avoid acoustic bridges, the use of Isolmant Fascia Perimetrale is recommended, to be laid along the entire perimeter of the room without interruption. The height of Isolmant Fascia Perimetrale must be chosen by the designer/contractor, taking into account the actual height at each site, in order to guarantee that the strip is about 2/3 cm higher than the flooring level. This excess must be trimmed after laying the floor (Fig. E). The continuity of the installation must also be ensured along the thresholds of entrance doors and French...
Open the catalog to page 7ISOLMANT SPECIAL > INSTALLATION SCREED CONSTRUCTION The finishing screed must guarantee adequate mechanical resistance according to the actual laying and loading conditions. Appropriate safety measures must be taken, such as assessing the adequate consistency of the mix, the curing time, the possible need to use collaborating elements (wire mesh or fibres), the sufficient compactness of the surface and the possible surface treatment with consolidating products (as indicated by the manufacturer of the screed and the reference standards). With reference to the thickness of the finishing screed,...
Open the catalog to page 8ISOLMANT SPECIAL WARNINGS: * This data sheet does not constitute a specification and, if it consists of several pages, please ensure that you have consulted the complete document. Although, these instructions are the result of our best expertise they are indicative. The user should establish whether the product is suitable for its intended application. The user will be also in charge of all the responsibility for the use of the product itself. **The sound insulation values given in this technical data sheet are the result of laboratory tests or tests carried out on site: they cannot be considered...