Miniset Multiset DCI
24Pages

{{requestButtons}}

Catalog excerpts

Miniset Multiset DCI - 1

R 4 1 0 A 54 U N E A V A N C E D A N S L ’ A I R D U T E M P S MINISET - MULTISET DC INVERTER Energy saving + maximale efficiency + easy installation and easy maintenance MINISET for the residential and service sectors • 3 indoor units - Single phase • from 1 to 9 indoor units to be connected • from 11.20 to 17.6 kW • Great length of piping (up to 150 meters) • Very wide range of indoor units MULTISET for the service sector • 2-way from 8 to 48 HP 5 outdoor units from 22.4 to 50 kW 21 possible combinations High COP until 40 indoor units can be connected Heating and cooling working • 3-way from 8 to 48 HP until 40 indoor units Simultaneous working in heating and cooling • 6 indoor unit types : a choice among 37 models • Reduction of refrigerated pipe diameters - Cooling charge decrease - Compact outdoor units - Maximum length of refrigerant lines: 300 m. Balancing of working times - Backup function - Silence mode - Hight slots of working - Progressive start-up function - Optimization of defrosting operating cycle, etc… Excellence with Multiset VRF system RENEWABLE ENERGIES D U C T A B L E C A S S E T T E U N D E R - C E I L I N G F L O O R / C E I L I N G W A L L - M O U N T E D ATTENTION These products are not available in some countries. Please, consult us.

Open the catalog to page 1
Miniset Multiset DCI - 2

56 57 55 58 59 60 64 64 65 66 67 68 70 72 for your environment Description of the system Outdoor units / Air to Air heat pumps MINISET DC INVERTER Description of the system Configuration Outdoor units / Air to Air heat pumps Indoor units Miniset/Multiset Wall-mounted MPAFM/MAFM Floor/ceiling KPAFM Under-ceiling SPAFM Extra-slim ducted SDAFM Ductable DSAFM Cassette CAFM Control and accessories MULTISET DC INVERTER VRF SYSTEMS MINISET/MULTISET DC INVERTER DC Inverter D i r e c t e x p a n s i o n Systems with Air to Air heat pumps

Open the catalog to page 2
Miniset Multiset DCI - 3

56 R 4 1 0 A 2009 Technibel CATALOGUE Air to Water and Air to Air heating and air-conditioning systems Indoor units, remote controls (as accessories) and system accessories are the same than for the MULTISET system. • DC Inverter compressor highly efficient, DCI PAM (DCInverter Pulse Amplitude Modulation) circuit, with a maximum of 9 indoor units connected. DC Inverter fan motor. • Variable Refrigerant Flow ; continuous regulation of the refrigerant flow rate in the circuit of an air conditioning system able to give the best in term of comfort, with very high efficiency levels (COP up to...

Open the catalog to page 3
Miniset Multiset DCI - 4

57 SPAFM SPAFM 255 R5I 365 R5I SPAFM 485 R5I CAFM 75 R5I CAFM 95 R5I CAFM 125 R5I CAFM 165 R5I CAFM 185 R5I CAFM 255 R5I CAFM 365 R5I CAFM 485 R5I MPAFM 78 R5I MPAFM 98 R5I MPAFM 128 R5I MAFM 185 R5I MAFM 255 R5I KPAFM 75 R5I KPAFM 95 R5I KPAFM 125 R5I KPAFM 165 R5I KPAFM 185 R5I KPAFM 225 R5I DSAFM 75 R5I DSAFM 95 R5I DSAFM 125 R5I DSAFM 165 R5I DSAFM 185 R5I DSAFM 225 R5I DSAFM 255 R5I DSAFM 365 R5I DSAFM 485 R5I SDAFM 76 R5I SDAFM 96 R5I SDAFM 126 R5I SDAFM 166 R5I SDAFM 186 R5I SDAFM 226 R5I 2009 Technibel CATALOGUE Air to Water and Air to Air heating and air-conditioning systems...

Open the catalog to page 4
Miniset Multiset DCI - 5

58 R 4 1 0 A SYSTEM DESCRIPTION MINISET DC INVERTER VRF SYSTEM Type 7 9 12 16 18 22 25 36 48 2.2 2.5 2.8 3.2 3.6 4.2 4.5 5.2 5.6 6.3 6.4 7.0 7.3 8.0 10.6 11.4 14.0 16.0 MAFM 255 R5I KPAFM 75 R5I KPAFM 95 R5I KPAFM 125 R5I KPAFM 165 R5I KPAFM 185 R5I KPAFM 225 R5I SPAFM 255 R5I SPAFM 365 R5I SPAFM 485 R5I CAFM 75 R5I CAFM 95 R5I CAFM 125 R5I CAFM 165 R5I CAFM 185 R5I CAFM 255 R5I CAFM 365 R5I CAFM 485 R5I DSAFM 75 R5I DSAFM 95 R5I DSAFM 125 R5I DSAFM 165 R5I DSAFM 185 R5I DSAFM 225 R5I DSAFM 255 R5I DSAFM 365 R5I DSAFM 485 R5I SDAFM 76 R5I SDAFM 96 R5I SDAFM 126 R5I SDAFM 166 R5I SDAFM 186...

Open the catalog to page 5
Miniset Multiset DCI - 7

60 R 4 1 0 A MINISET DC INVERTER VRF SYSTEM OUTDOOR UNITS 2-WAY SYSTEM • 5 Outdoor units caracterized by: - flexibility of installation - high efficiency (C.O.P.at the top of the range: 3.90 average cooling/heating for the 8 HP units) - reduced life cycle costs - accurate capacity control - compactness, making units easier to position - smaller pipeworks, making material costs lower - possibility to choose among a wide range of control options. • Maximum number of Outdoor units connectable: 3 Maximum total power of the system: 135 kW (48 HP) Maximum number of Indoor units connectable: 40 •...

Open the catalog to page 7
Miniset Multiset DCI - 8

61 Model GRFMI 708 R7I GRFMI 908 R7I Cooling Heating 22.40 25.00 3.74 4.05 9 000 54.5/51.5 400/3N/50 5.99 6.17 9.20 9.50 Twin Rotary DC Inverter R410A 9.52(3/8") 19.05(3/4") 6.35 (1/4“) 13 50-130 % 300 12 50 40 245 1 887 x 890 x 890 (+60) Cooling Heating 28.00 31.50 3.54 4.06 9 600 55/52 400/3N/50 7.90 7.75 12.30 12.00 Twin Rotary DC Inverter + Scroll R410A 9.52(3/8") 22.22(7/8") 6.35 (1/4“) 16 50-130 % 300 12 50 40 295 1 887 x 890 x 890 (+60) Performance Cooling capacity kW EER / COP (kW/kW) Air flow (m3/h) HS Sound pressure (normal/silent mode) (dB(A)) Power supply V/Ph/Hz Input power...

Open the catalog to page 8
Miniset Multiset DCI - 9

R 4 1 0 A 62 MINISET DC INVERTER VRF SYSTEM OUTDOOR UNITS 3-WAY SYSTEM • DC Inverter outdoor units for three-way Multiset VRF systems • Automatic change-over between cooling and heating modes for each indoor unit; this feature, based on the three-way technology with heat recovery, allows a fully independent operation of each indoor unit • R410A HFC refrigerant • Twin Rotary DC Inverter compressor, highly efficient at low rotation frequencies, matching with a Scroll Constant-Speed compressor • Fan with direct current motor that allows a consumption reduction of about 50% and a speed...

Open the catalog to page 9
Miniset Multiset DCI - 10

63 Electrovanne Example Model GRFMI3V 705 R7I (3-way) GRFMI3V 905 R7I (3-way) Cooling Heating 22.40 25.00 3.78 4.09 9 000 54.5/51.5 400/3N/50 5.93 6.11 9.50 9.80 Twin Rotary DC Inverter + Scroll CS R410A 9.52(3/8") 19.05(3/4") 15.88(5/8“) 6.35 (1/4“) 13 50-130 % 300 12.00 56 50 40 290 1 887 x 890 x 890 (+60) Cooling Heating 28.00 31.50 3.45 3.95 9 600 55/52 400/3N/50 8.12 7.97 13.00 12.8 Twin Rotary DC Inverter + Scroll CS R410A 9.52(3/8") 22.22(7/8") 19.05(3/4“) 6.35 (1/4“) 16 50-130 % 300 12.00 56 50 40 290 1 887 x 890 x 890 (+60) Performance Cooling capacity kW EER / COP (kW/kW) Air flow...