Overview: The document provides a comprehensive description of the MINISET and MULTISET DC Inverter systems by Technibel, designed for energy-efficient heating and cooling in residential and service sectors. These systems utilize advanced DC Inverter technology and R410A refrigerant for high efficiency and environmental friendliness.
MINISET System:
  • Designed for residential and light commercial applications.
  • Supports 1 to 9 indoor units with a power range from 11.20 to 17.6 kW.
  • Features a single-phase power supply and compact outdoor units.
  • Allows for a maximum piping length of 150 meters.
  • Utilizes a LAN for interconnecting units, simplifying installation and setup.
  • Operates efficiently in a wide range of outdoor temperatures.
MULTISET System:
  • Targeted at service sector applications with 2-way and 3-way configurations.
  • Supports up to 40 indoor units with a power range from 22.4 to 50 kW.
  • Offers simultaneous heating and cooling with heat recovery in 3-way systems.
  • Features a maximum refrigerant line length of 300 meters.
  • Includes advanced features like automatic backup, silence mode, and optimized defrosting cycles.
Technical Specifications:
  • Both systems use R410A refrigerant, known for its efficiency and ecological benefits.
  • DC Inverter technology provides high COP values, enhancing energy savings.
  • Outdoor units are compact and designed for easy installation and maintenance.
  • Sound levels are minimized through advanced fan and air movement designs.
  • Systems are adaptable to various building configurations and can be expanded with additional units.
Control and Accessories:
  • Both systems offer a wide range of control options and accessories for customization.
  • Intelligent controllers facilitate easy setup and operation of the systems.
Conclusion: The MINISET and MULTISET DC Inverter systems provide flexible, efficient, and environmentally friendly solutions for heating and cooling in residential and service sectors. Their advanced technology and design features make them suitable for a wide range of applications and conditions.
Product Overview: The document details the Technibel air-conditioning systems, specifically focusing on the VE 68 outdoor units ranging from 22 to 68 kW and the 3-way outdoor units distribution joint kit M3DDVE 135, which supports capacities from 68 to 135 kW. It highlights the ease of installation and the flexibility of adding indoor units.
Specifications: The systems can achieve a maximum power of 48 HP with outdoor units, and pipe lengths can extend up to 300 meters. The document specifies different distribution joint kits for both indoor and outdoor units, with capacities ranging from 22.4 kW to 135 kW.
Installation Procedures: The document provides guidelines for the installation of MULTISET DC Inverter systems, emphasizing the importance of following precise engineering rules for the refrigerant circuit. It includes the necessity of using Technibel's engineering and design software, distribution joint kits, and solenoid valve kits for proper system implementation.
System Validation and Start-up: Technibel requires validation of MULTISET systems before installation. This involves checking unit wiring, refrigeration circuits, vacuum pulling, and refrigerant charges. A checklist must be completed and returned before start-up authorization.
Examples of Installations: The document lists various installations of Technibel VRF systems across different locations, including hospitals, administrative buildings, and hotels, with the number of indoor units ranging from 6 to 114.
Recommendations: For a successful implementation, it is recommended to consult the complete MULTISET DC Inverter technical documentation and ensure compliance with EN standard 378 for refrigerant density in category 1 buildings.
See more

Catalog excerpts

Miniset Multiset DCI-1

R 4 1 0 A 54 U N E A V A N C E D A N S L ’ A I R D U T E M P S MINISET - MULTISET DC INVERTER Energy saving + maximale efficiency + easy installation and easy maintenance MINISET for the residential and service sectors • 3 indoor units - Single phase • from 1 to 9 indoor units to be connected • from 11.20 to 17.6 kW • Great length of piping (up to 150 meters) • Very wide range of indoor units MULTISET for the service sector • 2-way from 8 to 48 HP 5 outdoor units from 22.4 to 50 kW 21 possible combinations High COP until 40 indoor units can be connected Heating and cooling working • 3-way from 8 to 48 HP until 40 indoor units Simultaneous working in heating and cooling • 6 indoor unit types : a choice among 37 models • Reduction of refrigerated pipe diameters - Cooling charge decrease - Compact outdoor units - Maximum length of refrigerant lines: 300 m. Balancing of working times - Backup function - Silence mode - Hight slots of working - Progressive start-up function - Optimization of defrosting operating cycle, etc… Excellence with Multiset VRF system RENEWABLE ENERGIES D U C T A B L E C A S S E T T E U N D E R - C E I L I N G F L O O R / C E I L I N G W A L L - M O U N T E D ATTENTION These products are not available in some countries. Please, consult us.

 Open the catalog to page 1
Miniset Multiset DCI-2

56 57 55 58 59 60 64 64 65 66 67 68 70 72 for your environment Description of the system Outdoor units / Air to Air heat pumps MINISET DC INVERTER Description of the system Configuration Outdoor units / Air to Air heat pumps Indoor units Miniset/Multiset Wall-mounted MPAFM/MAFM Floor/ceiling KPAFM Under-ceiling SPAFM Extra-slim ducted SDAFM Ductable DSAFM Cassette CAFM Control and accessories MULTISET DC INVERTER VRF SYSTEMS MINISET/MULTISET DC INVERTER DC Inverter D i r e c t e x p a n s i o n Systems with Air to Air heat pumps

 Open the catalog to page 2
Miniset Multiset DCI-3

56 R 4 1 0 A 2009 Technibel CATALOGUE Air to Water and Air to Air heating and air-conditioning systems Indoor units, remote controls (as accessories) and system accessories are the same than for the MULTISET system. • DC Inverter compressor highly efficient, DCI PAM (DCInverter Pulse Amplitude Modulation) circuit, with a maximum of 9 indoor units connected. DC Inverter fan motor. • Variable Refrigerant Flow ; continuous regulation of the refrigerant flow rate in the circuit of an air conditioning system able to give the best in term of comfort, with very high efficiency levels (COP up to 4,34)...

 Open the catalog to page 3
Miniset Multiset DCI-4

57 SPAFM SPAFM 255 R5I 365 R5I SPAFM 485 R5I CAFM 75 R5I CAFM 95 R5I CAFM 125 R5I CAFM 165 R5I CAFM 185 R5I CAFM 255 R5I CAFM 365 R5I CAFM 485 R5I MPAFM 78 R5I MPAFM 98 R5I MPAFM 128 R5I MAFM 185 R5I MAFM 255 R5I KPAFM 75 R5I KPAFM 95 R5I KPAFM 125 R5I KPAFM 165 R5I KPAFM 185 R5I KPAFM 225 R5I DSAFM 75 R5I DSAFM 95 R5I DSAFM 125 R5I DSAFM 165 R5I DSAFM 185 R5I DSAFM 225 R5I DSAFM 255 R5I DSAFM 365 R5I DSAFM 485 R5I SDAFM 76 R5I SDAFM 96 R5I SDAFM 126 R5I SDAFM 166 R5I SDAFM 186 R5I SDAFM 226 R5I 2009 Technibel CATALOGUE Air to Water and Air to Air heating and air-conditioning systems Temperature...

 Open the catalog to page 4
Miniset Multiset DCI-5

58 R 4 1 0 A SYSTEM DESCRIPTION MINISET DC INVERTER VRF SYSTEM Type 7 9 12 16 18 22 25 36 48 2.2 2.5 2.8 3.2 3.6 4.2 4.5 5.2 5.6 6.3 6.4 7.0 7.3 8.0 10.6 11.4 14.0 16.0 MAFM 255 R5I KPAFM 75 R5I KPAFM 95 R5I KPAFM 125 R5I KPAFM 165 R5I KPAFM 185 R5I KPAFM 225 R5I SPAFM 255 R5I SPAFM 365 R5I SPAFM 485 R5I CAFM 75 R5I CAFM 95 R5I CAFM 125 R5I CAFM 165 R5I CAFM 185 R5I CAFM 255 R5I CAFM 365 R5I CAFM 485 R5I DSAFM 75 R5I DSAFM 95 R5I DSAFM 125 R5I DSAFM 165 R5I DSAFM 185 R5I DSAFM 225 R5I DSAFM 255 R5I DSAFM 365 R5I DSAFM 485 R5I SDAFM 76 R5I SDAFM 96 R5I SDAFM 126 R5I SDAFM 166 R5I SDAFM 186 R5I...

 Open the catalog to page 5
Miniset Multiset DCI-7

60 R 4 1 0 A MINISET DC INVERTER VRF SYSTEM OUTDOOR UNITS 2-WAY SYSTEM • 5 Outdoor units caracterized by: - flexibility of installation - high efficiency (C.O.P.at the top of the range: 3.90 average cooling/heating for the 8 HP units) - reduced life cycle costs - accurate capacity control - compactness, making units easier to position - smaller pipeworks, making material costs lower - possibility to choose among a wide range of control options. • Maximum number of Outdoor units connectable: 3 Maximum total power of the system: 135 kW (48 HP) Maximum number of Indoor units connectable: 40 • Twin...

 Open the catalog to page 7
Miniset Multiset DCI-8

61 Model GRFMI 708 R7I GRFMI 908 R7I Cooling Heating 22.40 25.00 3.74 4.05 9 000 54.5/51.5 400/3N/50 5.99 6.17 9.20 9.50 Twin Rotary DC Inverter R410A 9.52(3/8") 19.05(3/4") 6.35 (1/4“) 13 50-130 % 300 12 50 40 245 1 887 x 890 x 890 (+60) Cooling Heating 28.00 31.50 3.54 4.06 9 600 55/52 400/3N/50 7.90 7.75 12.30 12.00 Twin Rotary DC Inverter + Scroll R410A 9.52(3/8") 22.22(7/8") 6.35 (1/4“) 16 50-130 % 300 12 50 40 295 1 887 x 890 x 890 (+60) Performance Cooling capacity kW EER / COP (kW/kW) Air flow (m3/h) HS Sound pressure (normal/silent mode) (dB(A)) Power supply V/Ph/Hz Input power (kW)...

 Open the catalog to page 8
Miniset Multiset DCI-9

R 4 1 0 A 62 MINISET DC INVERTER VRF SYSTEM OUTDOOR UNITS 3-WAY SYSTEM • DC Inverter outdoor units for three-way Multiset VRF systems • Automatic change-over between cooling and heating modes for each indoor unit; this feature, based on the three-way technology with heat recovery, allows a fully independent operation of each indoor unit • R410A HFC refrigerant • Twin Rotary DC Inverter compressor, highly efficient at low rotation frequencies, matching with a Scroll Constant-Speed compressor • Fan with direct current motor that allows a consumption reduction of about 50% and a speed modulation...

 Open the catalog to page 9
Miniset Multiset DCI-10

63 Electrovanne Example Model GRFMI3V 705 R7I (3-way) GRFMI3V 905 R7I (3-way) Cooling Heating 22.40 25.00 3.78 4.09 9 000 54.5/51.5 400/3N/50 5.93 6.11 9.50 9.80 Twin Rotary DC Inverter + Scroll CS R410A 9.52(3/8") 19.05(3/4") 15.88(5/8“) 6.35 (1/4“) 13 50-130 % 300 12.00 56 50 40 290 1 887 x 890 x 890 (+60) Cooling Heating 28.00 31.50 3.45 3.95 9 600 55/52 400/3N/50 8.12 7.97 13.00 12.8 Twin Rotary DC Inverter + Scroll CS R410A 9.52(3/8") 22.22(7/8") 19.05(3/4“) 6.35 (1/4“) 16 50-130 % 300 12.00 56 50 40 290 1 887 x 890 x 890 (+60) Performance Cooling capacity kW EER / COP (kW/kW) Air flow (m3/h)...

 Open the catalog to page 10