1. Catalogs
  2. TECHNIBEL
  3. Hydronic Catalogue 2013

Hydronic Catalogue 2013

Hydronic Catalogue 2013
1 / 68 PagesView full catalog

Hydronic Catalogue 2013

Product catalog summary
Overview: The document is a 2013 catalogue for Technibel's hydronic systems, focusing on renewable energy solutions, particularly air/water heat pumps. It highlights the company's commitment to quality, sustainable development, and innovation in heating and cooling technologies.
Certifications and Quality: Technibel's products are certified for heating capacity, coefficient of performance (COP), and sound power level. The company is ISO 9001:2008 certified, emphasizing customer satisfaction and high performance standards.
Company Background: Founded in 1958 in France, Technibel became part of the Argoclima group in 1992. The production facilities are located in Italy and France, covering 82,000 m2, with 50,000 m2 under cover. The company focuses on minimizing delivery times and ensuring product quality through rigorous testing.
Research and Development: Technibel's R&D centers in France and Italy collaborate to design environmentally friendly products. The focus is on reducing energy consumption and greenhouse gas emissions, using technologies like R410A or R407C refrigerants and DC Inverter technology.
Product Range: The catalogue details various residential solutions with air/water heat pumps, including:
  • Boiler integration and replacement options for existing installations.
  • New installations with different heating zones and configurations.
  • Split and single-unit inverter systems with high efficiency and low noise levels.
Technical Specifications: The document provides detailed specifications for different models, including heating capacities, COP values, electrical and physical specifications, and installation requirements. It also includes information on operating ranges and sound levels.
Installation and Applications: Installation clearances and guidelines are provided, along with circuit diagrams for various applications. The systems are designed for flexibility, allowing integration with different heating and cooling configurations.
Key Features: Technibel's heat pumps offer benefits such as high COP, exceptional power modulation, advanced inverter technology, and low running noise. They are equipped with full water circuit equipment and a range of accessories.
AQUASET Range: The document provides detailed specifications and operational guidelines for the AQUASET range of air/water heat pumps, focusing on residential solutions. It covers both single-unit inverter and ON/OFF models, highlighting their heating and cooling capacities, circuit specifications, and installation requirements.
Specifications: The AQUASET models are available in various configurations, including heating-only and reversible options. Key specifications include:
  • Heating capacities range from 1.65 kW to 25.4 kW, depending on the model and conditions.
  • Coefficient of Performance (COP) varies with temperature settings, with nominal values provided for different scenarios.
  • Cooling capacities for reversible models range from 5.64 kW to 24.50 kW.
  • Electrical specifications include power requirements, startup current, and maximum current draw.
  • Sound power and pressure levels are specified for different operating modes.
Operating Conditions: The heat pumps operate within specific temperature ranges:
  • Heating: Air temperature from -20°C to +35°C, water temperature from +25°C to +55°C.
  • Cooling: Air temperature from +10°C to +43°C, water temperature from +5°C to +25°C.
Installation and Components: The document outlines installation clearances and includes details on integrated hydronic modules, which feature components like circulation pumps, air vents, and hydraulic filters. Control systems offer functionalities such as anti-freeze protection, defrosting regulation, and external communication via Modbus protocol.
Additional Features: The AQUASET range includes high-efficiency components such as scroll compressors with sound insulation, high-efficiency air heat exchangers, and helicoidal fans. The systems are designed for easy access to components and include features for alarm management and event logging.
Applications: The document references circuit diagrams for specific applications, indicating versatility in residential heating and cooling solutions.
LIBERTY 300 Thermodynamic Water Heater: Designed for domestic hot water, it can be installed in rooms over 20 m² or ducted outdoors. It reduces electricity bills by up to 70% and is compatible with Technibel heat pumps. It complies with standard EN355-3.
AQUASET-T Range: Includes heat pumps and chillers for service sector and small commercial applications. Offers eco-friendly solutions with high energy efficiency and low noise. Operating range from -20°C to +43°C, suitable for extreme conditions. Models include integrated hydronics module with water circulation pump and expansion tank.
CHG Models: Cooling capacity ranges from 8.1 kW to 16.3 kW with low running noise. Features include dynamic temperature setpoint and remote control options. Operating air temperature range from -10°C to +43°C.
CHGF Models: Cooling capacity ranges from 20 kW to 76 kW with high energy efficiency. Equipped with dual pump options and capable of operating in ambient temperatures from +47°C to -10°C.
PHRF Models: Heating capacity ranges from 23 kW to 85 kW with low running noise. Features include integrated hydronic module and dual pump options. Operational air temperature range from +47°C to -10°C.
Installation and Accessories: Detailed installation clearances and accessory options are provided for each model. Accessories include remote controls, RS 485 communication interfaces, and battery protection grilles.
MPW, KPSW, CWX, and TWN Models: These systems are designed for climate control in different settings such as offices, warehouses, and hotels. The document details the dimensions, weight, and installation clearances for each model. It includes information on cooling and heating capacities, air and water flow rates, pressure drops, and sound levels. The systems conform to European standard EN 12102 for sound pressure levels.
Conclusion: The document serves as a comprehensive guide for selecting and installing hydronic systems, offering detailed technical data and accessory options to ensure efficient climate control solutions.
See more

Catalog excerpts

Hydronic Catalogue 2013-1

UNE AVANCE DANS L'AIR DU TEMPS HYDRONIC SYSTEMS

 Open the catalog to page 1
Hydronic Catalogue 2013-2

THE COMPANY Originally founded in 1958 near Lyon, France, in 1992 TECHNIBEL joined the Argoclima group (based near Milan), a leader in the air-conditioning, heating and air treatment industry. Production The products made by our group are manufactured in Italy, France. RENEWABLE ENERGIES Research and Development The Research Centre and Laboratories in France and Italy work in close partnership, using the most advanced technology to design new and environmentally-friendly products for personal comfort. The facilities at Gallarate (Italy) and Reyrieux (France) cover a total area of 82,000 m2, 50,000...

 Open the catalog to page 2
Hydronic Catalogue 2013-3

Hydronic Systems Residential solutions with air/water heat pumps pag. 5 Heat pump for domestic hot water pag. 31 Cooling units and heat pumps Terminal units

 Open the catalog to page 3
Hydronic Catalogue 2013-5

Residential solutions with air/water heat pumps

 Open the catalog to page 5
Hydronic Catalogue 2013-6

Residential solutions with air/water heat pumps ON/OFF SYSTEMS EXISTING INSTALLATIONS Boiler integration (1) 65°C 1 underfloor heating zone 65°C 2 mixed zones: underfloor heating + radiators 60°C 1 underfloor heating zone 60°C 2 mixed zones: underfloor heating + radiators 55°C 2 mixed zones: underfloor heating/cooling + radiators 55°C 2 underfloor heating/cooling zones 1 underfloor heating/cooling zone Boiler replacement NEW INSTALLATIONS 1 radiator zone 1 underfloor heating/cooling zone 40°C 2 underfloor heating/cooling zones 40°C Mixed: underfloor heating/cooling + terminal units 55°C Mixed:...

 Open the catalog to page 6
Hydronic Catalogue 2013-7

INVERTER systems EXISTING INSTALLATIONS

 Open the catalog to page 7
Hydronic Catalogue 2013-8

Residential solutions with air/water heat pumps New products Air/Water Heat Pumps Split INVERTER Heating (or reversible) AQUASET-S - PSHRI-iSERIES A TECHNIBEL exclusive : With a single outdoors unit you can hook up to the HK hydronic unit for air/water applications, and at the same time, to an air/air indoors unit. Refer to the circuit diagrams Example : underfloor heating/cooling in one zone and direct expansion indoors unit in a second zone. Benefits Split models with cooling connections Models 5 - 13 kW in heating Defrost without downtime Integration with 2-stage heating element Complete hydronic...

 Open the catalog to page 8
Hydronic Catalogue 2013-9

Residential solutions with air/water heat pumps AQUASET-S MODELS Inside Unit Outside Unit Heating capacity Heating +7°C/35°C floor (kW) (Min /Nom / Max) COP +7°C/+35°C floor Heating -7°C/35°C floor (kW) (Nom / Max) COP -7°C/+35°C floor Nominal Heating +7°C/45°C LT radiators Nom/Max (kW) COP +7°C/+45°C LT radiators Nominal Heating -7°C/45°C LT radiators (kW) Nom/Max COP -7°C/+45°C LT radiators Nominal OUTDOOR UNIT Cooling specifications Distance min / max UI/ UE (m) R410A refrigerant charge (kg) Additional gas per metre (gr) Number of fittings External gas-fluid fittings HK gas-fluid fittings...

 Open the catalog to page 9
Hydronic Catalogue 2013-10

► Residential solutions with air/water heat pumps Air/Water Heat AQUASET"S Medium temperature ^ '^J^^ Refer to the circuit diagrams on pages 30 to 34 generated in Heating mode: 50°C • Power varies from 32 to 130% of • Integrated electric module • Heating mode operation from • Cooling mode operation from > The best COP values on the market Twin rotary DC Inverter compressor with sound insulation - High-efficiency heat exchanger with fins for R 410 A - Helicoidal fan motor - Plate heat exchanger in AISI 316 stainless steel with heat insulation, ... 3-speed circulation pump - Expansion tank - Safety...

 Open the catalog to page 10
Hydronic Catalogue 2013-11

Residential solutions with air/water heat pumps HEATIING SYSTEM WITH 1 LOW TEMPERATURE RADIATOR ZONE WITH OR WITHOUT DOMESTIC HOT WATER GENERATION UNDERFLOOR HEATING/COOLING SYSTEM (1 ZONE OR 2 ZONES) MIXED UNDERFLOOR HEATING/COOLING AND TERMINAL UNIT SYSTEM MIXED UNDERFLOOR HEATING AND LOW TEMPERATURE RADIATOR SYSTEM SYSTEM WITH TERMINAL UNITS 369 R5/7 Indoor Units 230/1/50 (-400/3N/50) Outdoor Units 230/1/50 Outdoor Units 400/3N/50 Conditions: temperature of water at inlet/outlet 30/35°C and temperature of air at inlet 7/6°C (DB/WB); net values; NF PAC; ref. Tax credit Nominal min./max. heating...

 Open the catalog to page 11
Hydronic Catalogue 2013-12

► Residential solutions with air/water heat pumps Air/Water Heat Single-unit INVERTER Refer to the circuit diagrams on pages 30 to 34 • Heating with boiler integration • Terminal units

 Open the catalog to page 12
Hydronic Catalogue 2013-13

Residential solutions with air/water heat pumps AQUASET range Air/Water Heat Pumps Single-unit INVERTER Heating (or reversible) Benefits AQUASET models 6 - 11 heating only (cooling option) The largest inverter range on the market The highest COP on the market Exceptional power modulation, 30 to 140 % Advanced Digital Hybrid (ADH) inverter High performance at low temperatures: 55°C to -10°C outdoors temperature Class A water circulation pump Very low running noise, with super quiet mode 2 stage power heating elements included Full water circuit equipment Complete range of accessories Installation...

 Open the catalog to page 13
Hydronic Catalogue 2013-14

Residential solutions with air/water heat pumps Air/Water Heat Pumps Single-unit INVERTER Heating (or reversible) AQUASET range AQUASET MODELS Electrical specifications and connections Power 50 Hz Startup current (A) Max current draw with heating element (A) Thermal cutout rating (A) Power cord cross section (1) Running noise Sound power per EN12102 (dB(A)) Sound pressure level at 10 m (dB(A)) (3) Model codes, heating only Reversible model codes Heating capacity Heating +7°C/35°C floor Min/Nom/Max (kW) COP +7°C/+35°C floor Nominal Heating -7°C/35°C floor Nom/Max (kW) COP -7°C/+35°C floor Nominal...

 Open the catalog to page 14
Hydronic Catalogue 2013-15

Residential solutions with air/water heat pumps AQUASET range Air/Water Heat Pumps Single-unit INVERTER Heating (or reversible) AQUASET MODELS Reversible model codes Heating capacity Heating +7°C/35°C floor Min/Nom/Max (kW) COP +7°C/+35°C floor Nominal Heating -7°C/35°C floor Nom/Max (kW) COP -7°C/+35°C floor Nominal Heating +7°C/45°C LT radiators Nom/Max (kW) COP +7°C/+45°C LT radiators Nominal Heating -7°C/45°C LT radiators Max (kW) COP -7°C/+45°C LT radiators Nominal Heating +7°C/55°C radiators Nom/Max (kW) COP +7°C/+55°C radiators Nominal Heating -7°C/55°C radiators (kW) COP -7°C/+55°C radiators...

 Open the catalog to page 15
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.