UNE AVANCE DANS L'AIR DU TEMPS HYDRONIC SYSTEMS

Open the catalog to page 1
Hydronic Catalogue 2013 - 2

THE COMPANY Originally founded in 1958 near Lyon, France, in 1992 TECHNIBEL joined the Argoclima group (based near Milan), a leader in the air-conditioning, heating and air treatment industry. Production The products made by our group are manufactured in Italy, France. RENEWABLE ENERGIES Research and Development The Research Centre and Laboratories in France and Italy work in close partnership, using the most advanced technology to design new and environmentally-friendly products for personal comfort. The facilities at Gallarate (Italy) and Reyrieux (France) cover a total area of 82,000 m2,...

Open the catalog to page 2
Hydronic Catalogue 2013 - 3

Hydronic Systems Residential solutions with air/water heat pumps pag. 5 Heat pump for domestic hot water pag. 31 Cooling units and heat pumps Terminal units

Open the catalog to page 3
Hydronic Catalogue 2013 - 5

Residential solutions with air/water heat pumps

Open the catalog to page 5
Hydronic Catalogue 2013 - 6

Residential solutions with air/water heat pumps ON/OFF SYSTEMS EXISTING INSTALLATIONS Boiler integration (1) 65°C 1 underfloor heating zone 65°C 2 mixed zones: underfloor heating + radiators 60°C 1 underfloor heating zone 60°C 2 mixed zones: underfloor heating + radiators 55°C 2 mixed zones: underfloor heating/cooling + radiators 55°C 2 underfloor heating/cooling zones 1 underfloor heating/cooling zone Boiler replacement NEW INSTALLATIONS 1 radiator zone 1 underfloor heating/cooling zone 40°C 2 underfloor heating/cooling zones 40°C Mixed: underfloor heating/cooling + terminal units 55°C...

Open the catalog to page 6
Hydronic Catalogue 2013 - 7

INVERTER systems EXISTING INSTALLATIONS

Open the catalog to page 7
Hydronic Catalogue 2013 - 8

Residential solutions with air/water heat pumps New products Air/Water Heat Pumps Split INVERTER Heating (or reversible) AQUASET-S - PSHRI-iSERIES A TECHNIBEL exclusive : With a single outdoors unit you can hook up to the HK hydronic unit for air/water applications, and at the same time, to an air/air indoors unit. Refer to the circuit diagrams Example : underfloor heating/cooling in one zone and direct expansion indoors unit in a second zone. Benefits Split models with cooling connections Models 5 - 13 kW in heating Defrost without downtime Integration with 2-stage heating element Complete...

Open the catalog to page 8
Hydronic Catalogue 2013 - 9

Residential solutions with air/water heat pumps AQUASET-S MODELS Inside Unit Outside Unit Heating capacity Heating +7°C/35°C floor (kW) (Min /Nom / Max) COP +7°C/+35°C floor Heating -7°C/35°C floor (kW) (Nom / Max) COP -7°C/+35°C floor Nominal Heating +7°C/45°C LT radiators Nom/Max (kW) COP +7°C/+45°C LT radiators Nominal Heating -7°C/45°C LT radiators (kW) Nom/Max COP -7°C/+45°C LT radiators Nominal OUTDOOR UNIT Cooling specifications Distance min / max UI/ UE (m) R410A refrigerant charge (kg) Additional gas per metre (gr) Number of fittings External gas-fluid fittings HK gas-fluid...

Open the catalog to page 9
Hydronic Catalogue 2013 - 10

► Residential solutions with air/water heat pumps Air/Water Heat AQUASET"S Medium temperature ^ '^J^^ Refer to the circuit diagrams on pages 30 to 34 generated in Heating mode: 50°C • Power varies from 32 to 130% of • Integrated electric module • Heating mode operation from • Cooling mode operation from > The best COP values on the market Twin rotary DC Inverter compressor with sound insulation - High-efficiency heat exchanger with fins for R 410 A - Helicoidal fan motor - Plate heat exchanger in AISI 316 stainless steel with heat insulation, ... 3-speed circulation pump - Expansion tank -...

Open the catalog to page 10
Hydronic Catalogue 2013 - 11

Residential solutions with air/water heat pumps HEATIING SYSTEM WITH 1 LOW TEMPERATURE RADIATOR ZONE WITH OR WITHOUT DOMESTIC HOT WATER GENERATION UNDERFLOOR HEATING/COOLING SYSTEM (1 ZONE OR 2 ZONES) MIXED UNDERFLOOR HEATING/COOLING AND TERMINAL UNIT SYSTEM MIXED UNDERFLOOR HEATING AND LOW TEMPERATURE RADIATOR SYSTEM SYSTEM WITH TERMINAL UNITS 369 R5/7 Indoor Units 230/1/50 (-400/3N/50) Outdoor Units 230/1/50 Outdoor Units 400/3N/50 Conditions: temperature of water at inlet/outlet 30/35°C and temperature of air at inlet 7/6°C (DB/WB); net values; NF PAC; ref. Tax credit Nominal min./max....

Open the catalog to page 11
Hydronic Catalogue 2013 - 12

► Residential solutions with air/water heat pumps Air/Water Heat Single-unit INVERTER Refer to the circuit diagrams on pages 30 to 34 • Heating with boiler integration • Terminal units

Open the catalog to page 12
Hydronic Catalogue 2013 - 13

Residential solutions with air/water heat pumps AQUASET range Air/Water Heat Pumps Single-unit INVERTER Heating (or reversible) Benefits AQUASET models 6 - 11 heating only (cooling option) The largest inverter range on the market The highest COP on the market Exceptional power modulation, 30 to 140 % Advanced Digital Hybrid (ADH) inverter High performance at low temperatures: 55°C to -10°C outdoors temperature Class A water circulation pump Very low running noise, with super quiet mode 2 stage power heating elements included Full water circuit equipment Complete range of accessories...

Open the catalog to page 13
Hydronic Catalogue 2013 - 14

Residential solutions with air/water heat pumps Air/Water Heat Pumps Single-unit INVERTER Heating (or reversible) AQUASET range AQUASET MODELS Electrical specifications and connections Power 50 Hz Startup current (A) Max current draw with heating element (A) Thermal cutout rating (A) Power cord cross section (1) Running noise Sound power per EN12102 (dB(A)) Sound pressure level at 10 m (dB(A)) (3) Model codes, heating only Reversible model codes Heating capacity Heating +7°C/35°C floor Min/Nom/Max (kW) COP +7°C/+35°C floor Nominal Heating -7°C/35°C floor Nom/Max (kW) COP -7°C/+35°C floor...

Open the catalog to page 14
Hydronic Catalogue 2013 - 15

Residential solutions with air/water heat pumps AQUASET range Air/Water Heat Pumps Single-unit INVERTER Heating (or reversible) AQUASET MODELS Reversible model codes Heating capacity Heating +7°C/35°C floor Min/Nom/Max (kW) COP +7°C/+35°C floor Nominal Heating -7°C/35°C floor Nom/Max (kW) COP -7°C/+35°C floor Nominal Heating +7°C/45°C LT radiators Nom/Max (kW) COP +7°C/+45°C LT radiators Nominal Heating -7°C/45°C LT radiators Max (kW) COP -7°C/+45°C LT radiators Nominal Heating +7°C/55°C radiators Nom/Max (kW) COP +7°C/+55°C radiators Nominal Heating -7°C/55°C radiators (kW) COP -7°C/+55°C...

Open the catalog to page 15