1. Catalogs
  2. Techneau
  3. HYDRAULIC EQUIPMENTS

HYDRAULIC EQUIPMENTS

HYDRAULIC EQUIPMENTS
1 / 32 PagesView full catalog

HYDRAULIC EQUIPMENTS

Product catalog summary
Overview
This document provides comprehensive information on hydraulic equipment used in water management, focusing on flow controllers, penstocks, and flap valves. These devices are crucial for regulating wastewater and rainwater in infrastructures such as storm basins, overflow holes, and sewage treatment plants.
Flow Controllers
  • Operating Principles: Flow controllers maintain a constant outflow regardless of upstream water levels, utilizing principles like the hydraulic vortex effect and surface water intake.
  • Product Ranges: Includes HydroRégul, HydroVortex, HydroDB, and HydroSurf, each designed for specific flow rates and water heights.
  • Model Selection and Installation: Criteria include wastewater type, flow rate, water height, and installation type, with options for open-air or chamber installations.
Penstocks
  • Service and Manufacture: Custom-made penstocks available in various configurations, including motorized options and those with PEHD disks.
  • Configurations: Designed to suit specific installation needs, with options for manual control and motorization.
Flap Valves
  • Hydroclap Range: Designed to prevent backflow, available for wall mounting or installation on PVC pipes.
Key Specifications and Recommendations
  • Flow controllers are recommended for light wastewater and rainwater, with specific models not suitable for heavy wastewater.
  • Installation requires precise alignment and fastening for optimal performance.
  • Regulation precision is critical, with some models offering adjustments within a 5% margin.
Technical Specifications
  • Flow controllers are constructed from 316L stainless steel, ensuring durability and corrosion resistance.
  • Penstocks are made from hot galvanized steel or 304L stainless steel, featuring full-flow round orifices and removable EPDM seals.
  • Flap valves are made of polyester with EPDM seals and 304L stainless steel bolts.
Installation and Maintenance
  • Installation requires smooth, vertical concrete walls for wall-mounted devices or horizontal pipes for mounted devices.
  • Maintenance involves ensuring proper sealing and adjusting components as needed.
Norms and Standards
  • Materials comply with NF A 91121 standards for hot galvanized steel.
  • Pressure resistance for flap valves is 0.5 bar (5 m water head).
Key Data from Tables
  • Weights for galvanized and stainless steel penstocks range from 9.1 kg to 48.4 kg depending on size.
  • Flap valve dimensions and weights vary by diameter, with Dn 315 weighing 5.2 kg and Dn 500 weighing 9.6 kg for wall-mounted devices.
Conclusion
The document provides detailed guidance on selecting and installing hydraulic equipment for effective water management, emphasizing the importance of choosing the right model based on specific operational requirements.
Contact Information
Techneau, Z.A. La Chevalerie, 50570 Marigny, France. Tel: +33 (0)2 33 56 62 08, Email: [email protected]
See more

Catalog excerpts

HYDRAULIC EQUIPMENTS-1

HYDRAULIC EQUIPMENTS Flow controllers, penstocks, flap valves Edition 03/2008 W a t e r m a n a g e m e n t

 Open the catalog to page 1
HYDRAULIC EQUIPMENTS-3

Z.A. La Chevalerie - 50570 MARIGNY - France Tel.: +33 (0)2 33 56 62 08 - Fax: +33 (0)2 33 56 61 93 E-mail : [email protected] - www.techneau.fr Flow controllers Hydraulic Equipments © 2008 - All rights reserved 2 Flow controllers This device operates on the hydraulic Vortex principle: an increase of the rotating speed in the regulation cone creates a load loss that in turn causes a reduction of the hydraulic cross-section. Flow controllers The graph to the right shows the flow rate curves of a flow nozzle with a 45-mm diameter and a RDM1020 controller (see page 5) for a maximum flow rate of 8...

 Open the catalog to page 3
HYDRAULIC EQUIPMENTS-4

Z.A. La Chevalerie - 50570 MARIGNY - France Tel.: +33 (0)2 33 56 62 08 - Fax: +33 (0)2 33 56 61 93 E-mail: [email protected] - www.techneau.fr Flow controllers Hydraulic Equipments © 2008 - All rights reserved 3 The HydroSurf flow controller combines two operations, regulation and skimming. The water intake at the surface allows highly precise regulation (+ or – 5%) (see curve to the right). It can regulate flow rates from 5 to 170 l/s for a maximum water height of 2 m and it can be installed on outlets with a cross-section from 100 to 350 mm. It is very suitable for installation in a basin before...

 Open the catalog to page 4
HYDRAULIC EQUIPMENTS-6

Z.A. La Chevalerie - 50570 MARIGNY - France Tel.: +33 (0)2 33 56 62 08 - Fax: +33 (0)2 33 56 61 93 E-mail: [email protected] - www.techneau.fr Flow controllers Hydraulic Equipments © 2008 - All rights reserved 5 HydroRégul F l o w c o n t r o l l e r Flow rate 4 -> 360 l/s Maximum water height: 3 m Installation : upstream For light waste water & rain water Manufacture Dn 100 to 500 Models with side arm RDM or RDF & guillotine closing valve RDMV or RDFV • 304L stainless steel frame with drilled holes for wall fastening and lifting rings • Dn 100 to Dn 350 (RDM or RDMV): Removable plate to adjust...

 Open the catalog to page 6
HYDRAULIC EQUIPMENTS-7

Z.A. La Chevalerie - 50570 MARIGNY - France Tel.: +33 (0)2 33 56 62 08 - Fax: +33 (0)2 33 56 61 93 E-mail: [email protected] - www.techneau.fr Flow controllers Hydraulic Equipments © 2008 - All rights reserved 6 Flow controllers Product selection HydroRégul F l o w c o n t r o l l e r Models with side arm RDM, RDMV, RDF & RDFV • HydroRégul is not recommended for use with heavy waste water. • A flow controller is determined in accordance with the flow rate to be regulated (Q) in l/s, and the maximum water level height (H) in meters. • The table below enables a model to be selected according to...

 Open the catalog to page 7
HYDRAULIC EQUIPMENTS-8

Specific equipment for the RDLV and RDTV • Closing valve with stainless steel operating rod and polyethylene guillotine Z.A. La Chevalerie - 50570 MARIGNY - France Tel. : +33 (0)2 33 56 62 08 - Fax : +33 (0)2 33 56 61 93 E-mail: [email protected] - www.techneau.fr Flow controllers Hydraulic Equipments © 2008 - All rights reserved 7 HydroRégul F l o w c o n t r o l l e r Flow rate 4 -> 360 l/s Maximum water height: 3 m Installation: upstream For light waste water & rain water Manufacture Dn 100 to 500 Models with side arm RDL or RDT & guillotine closing valve RDLV or RDTV • 304L stainless steel...

 Open the catalog to page 8
HYDRAULIC EQUIPMENTS-9

Z.A. La Chevalerie - 50570 MARIGNY - France Tel.: +33 (0)2 33 56 62 08 - Fax: +33 (0)2 33 56 61 93 E-mail: [email protected] - www.techneau.fr Flow controllers Hydraulic Equipments © 2008 - All rights reserved 8 Flow controllers Product selection HydroRégul F l o w c o n t r o l l e r Models with side arm RDL, RDLV, RDT & RDTV • HydroRégul is not recommended for use with heavy waste water. • A flow controller is determined in accordance with the flow rate to be regulated (Q) in l/s, and the maximum water level height (H) in meters. • The table below enables a model to be selected according to...

 Open the catalog to page 9
HYDRAULIC EQUIPMENTS-12

Z.A. La Chevalerie - 50570 MARIGNY - France Tel.: +33 (0)2 33 56 62 08 - Fax: +33 (0)2 33 56 61 93 E-mail: [email protected] - www.techneau.fr Flow controllers Hydraulic Equipments © 2008 - All rights reserved 11 Height 1 m 1,5 m 2 m 2,5 m 3 m 5 l/s CY00510 CY00515 CY00520 CY00525 CY00530 From 6 to 10 l/s CY01010 CY01015 CY01020 CY01025 CY01030 From 11 to 15 l/s CY01510 CY01515 CY01520 CY01525 CY01530 From 16 to 20 l/s CY02010 CY02015 CY02020 CY02025 CY02030 From 21 to 30 l/s CY03010 CY03015 CY03020 CY03025 CY03030 From 31 to 50 l/s CY05010 CY05015 CY05020 CY05025 CY05030 From 51 to 80 l/s CY08010...

 Open the catalog to page 12
HYDRAULIC EQUIPMENTS-13

Z.A. La Chevalerie - 50570 MARIGNY - France Tel.: +33 (0)2 33 56 62 08 - Fax: +33 (0)2 33 56 61 93 E-mail: [email protected] - www.techneau.fr Flow controllers Hydraulic Equipments © 2008 - All rights reserved 12 Flow controllers Min. 40 cm Water height Manufacture Height 0.5 m 1 m 1.5 m 2 m 2.5 m 3 m From 1 to 3 l/s CEV03005 CEV03010 CEV03015 CEV03020 CEV03025 CEV03030 From 4 to 6 l/s CEV06005 CEV06010 CEV06015 CEV06020 CEV06025 CEV06030 From 7 to 10 l/s CEV10005 CEV10010 CEV10015 CEV10020 CEV10025 CEV10030 From 11 to 15 l/s CEV15005 CEV15010 CEV15015 CEV15020 CEV15025 CEV15030 From 16 to 20...

 Open the catalog to page 13
HYDRAULIC EQUIPMENTS-14

Z.A. La Chevalerie - 50570 MARIGNY - France Tel.: +33 (0)2 33 56 62 08 - Fax: +33 (0)2 33 56 61 93 E-mail: [email protected] - www.techneau.fr Flow controllers Hydraulic Equipments © 2008 - All rights reserved 13 • A flow controller is determined in accordance with the flow rate to be regulated (Q) in l/s, and the maximum water level height (H) in meters. Selection HydroVortex F l o w c o n t r o l l e r Flow rate 10 -> 350 l/s Maximum water height: 6 m Installation: downstream For heavy waste water and rain water Manufacture Vortex models CYDX • The HydroVortex range is made of 316L stainless...

 Open the catalog to page 14
HYDRAULIC EQUIPMENTS-15

Z.A. La Chevalerie - 50570 MARIGNY - France Tel.: +33 (0)2 33 56 62 08 - Fax: +33 (0)2 33 56 61 93 E-mail: [email protected] - www.techneau.fr Flow controllers Hydraulic Equipments © 2008 - All rights reserved 14 Flow controllers Half-pipe shaped channel for proper flow Manufacture • This type of device requires a particular design for each model. Please contact our design office and stipulate the height (H) and flow rate (Q) desired. Selection HydroDB Flow contro l l e r Flow rate 30 -> 1,000 l/s Maximum water height: 6 m Installation: upstream For heavy waste water Dual diaphragm models & rain...

 Open the catalog to page 15

All Techneau catalogs and technical brochures

  1. HydroSurf

    2  Pages

  2. HydroRégul

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.