Sanitary systems TECHNICAL GUIDELINES

Open the catalog to page 1
TECEone Sanitary systems TECHNICAL GUIDELINES - 3

Water connection device Mounting the toilet ceramic Temperature adjustment Mounting the toilet seat Servicing and replacement parts

Open the catalog to page 3
TECEone Sanitary systems TECHNICAL GUIDELINES - 4

TECEone – Introduction Introduction TECEone is a wall-mounted toilet ceramic with a shower function, intended for washing your backside and intimate areas. It can also be used as an ordinary toilet ceramic without the shower function. TECEone not only shines with inner values — it looks pretty good too! Thanks to its timeless, elegant design, it integrates into any bathroom ambience, and combines well with existing bathroom furnishings. 1 Hot and cold water connection, angle valves 2 Temperature setting rotary knob, thermostat valve 3 Water volume rotary knob 4 Shower unit with shower arm 5...

Open the catalog to page 4
TECEone Sanitary systems TECHNICAL GUIDELINES - 5

TECEone – System description Dimensions Rotary knobs for controlling the volume of water and regulating the temperature Toilet seat The ergonomically-shaped toilet seat and lid with soft-close function have been developed specially for TECEone. The attachment is already installed and immovably cast with the ceramic. Technical data Temperature range 10-38 °C Water pressure min. 1 bar (0.1 MPa) max. 10 bar (1 MPa) up to 5.6 l/min. Approval and certificates TECEone complies with all relevant standards and guidelines. The DVGW W 540 mark of conformity confirms that TECEone is equipped with the...

Open the catalog to page 5
TECEone Sanitary systems TECHNICAL GUIDELINES - 6

TECEone – Operation Operation Operating elements TECEone is operated intuitively using the right and left rotary knobs: • Fully turn the right rotary knob: The shower arm now extends completely and you can start washing with water (pictured right). • You can increase or reduce the volume of water by turning the right rotary knob until you achieve the required result. • You can set the required temperature of water by turning the left rotary knob – including during operation. • To turn off the shower function, turn the knob back as far as it will go. Remove the toilet lid. • “Water...

Open the catalog to page 6
TECEone Sanitary systems TECHNICAL GUIDELINES - 7

TECEone – Planning and assembly Planning and assembly Water connection device PWC kalt cold froid frio freddo zimna холодный TECEone is operated with fresh hot and cold water from the pipe. Corresponding upgrade kits are available for installing and precisely positioning the water connections for the different TECE modules: PWH warm hot chaud caliente caldo ciepła теплый Brick wall connection and dimensions Dry-wall upgrade kit Order number 9880046 Brick wall upgrade kit Order number 9880047 You can find the information required for using a TECElux module in connection with a TECE in the...

Open the catalog to page 7
TECEone Sanitary systems TECHNICAL GUIDELINES - 8

TECEone – Planning and assembly max. 7 Nm! Attach the sound insulation strips to the back of the ceramic. Secure it with the concealed fitting (13 mm ratchet) from the underside of the toilet ceramic. Observe the maximum torque of 10 Nm. PWH warm hot chaud caliente caldo ciepła теплый PWC kalt cold froid frio freddo zimna холодный Combine the colour-coded reinforced hoses with the appropriate corner valves. Use conventional corner valves with a maximum length of 85 mm. Push the ceramic against the wall with the aid of the mounting accessory (packaging). To flush the protective device...

Open the catalog to page 8
TECEone Sanitary systems TECHNICAL GUIDELINES - 9

Temperature adjustment After installing the toilet ceramic, check the hot water temperature, as is the customary procedure when using thermostatic cartridges. First, remove the cap from the rotary knob. > 38 °C Then remove the cap holding fixture — the screw is secured with a seal. However, if the measured water temperature is higher than 38 °C, follow the steps below to adjust the temperature. To do this, turn the temperature controller to the maximum temperature, then open the water volume control knob and measure the temperature. If the measured temperature is not higher than 38 °C, you...

Open the catalog to page 9
TECEone Sanitary systems TECHNICAL GUIDELINES - 10

TECEone – Planning and assembly Now open the water volume control knob and measure the Tighten the screw. temperature again. If the temperature is still too high, turn the marking on the toothed shaft slightly to the right. Turn the cap holding fixture up to the left stop, then turn it 90° to the right. Fit the cap holding fixture onto the toothed shaft until it reaches the stop (scald protection). 10-10 Place the rotary knob cap on the fixture so that the marking is pointing upw

Open the catalog to page 10
TECEone Sanitary systems TECHNICAL GUIDELINES - 11

TECEone – Cleaning and maintenance Mounting the toilet seat TECEone should always be used in combination with the TECEone set with lid . The toilet seat and lid fixings are already in place and immovably cast with the ceramic. Cleaning and maintenance Lid and toilet seat, control knobs Clean the lid, toilet seat and control knobs every day using a soft cloth and warm water with a mild household cleaner. Do not use abrasive, chlorine-based or acidic cleaning products. When cleaning the ceramic, always open the lid or remove it completely so that any rising vapours cannot damage the plastic....

Open the catalog to page 11
TECEone Sanitary systems TECHNICAL GUIDELINES - 12

TECEone – Servicing and replacement parts Faults Servicing and replacement parts The TECEone has been built in such a way that problems are extremely unlikely and may only occur in very few cases. However, if a fault should occur, it is generally best to contact a suitable specialist (i.e. fitter). TECE trusts in proven technology, however, should any components need to be replaced or serviced, TECEone replacement parts are listed below. Possible cause Water is running/ dripping out of the ceramic. Solution Close the corner valve or the main valve and call the fitter. The shower arm does...

Open the catalog to page 12
TECEone Sanitary systems TECHNICAL GUIDELINES - 13

Shower nozzle caps TECEone shower nozzle caps come in four versions which differ from each other in terms of intensity and position of the shower spray: „standard“ 75° 75° The as-delivered state of the TECEone includes three “sta

Open the catalog to page 13
TECEone Sanitary systems TECHNICAL GUIDELINES - 15

All data contained in the Technical Guidelines has been compiled with the utmost care. The correctness of the data presented cannot be guaranteed, however. TECE assumes no liability for damages resulting from the use of this information. Text and images are protected by copyright law. © Copyright 2018, TECE GmbH, Hollefeldstraße 57, 48282 Emsdetten, Germany