TECEbox
16Pages

{{requestButtons}}

Catalog excerpts

TECEbox - 1

Sanitary systems TECHNICAL INFORMATION

Open the catalog to page 1
TECEbox - 2

All data contained in the Technical Information has been compiled with the utmost care. However, the correctness of the data presented cannot be guaranteed. TECE assumes no liability for damage resulting from the use of this information. Text and images are protected by copyright law. Issue: March 2020 © Copyright 2020, TECE GmbH, Hollefeldstraße 57, D-48282 Emsdetten

Open the catalog to page 2
TECEbox - 3

TECEbox installation - low installation height 3-6 TECEbox plus installation 3-8 TECEone upgrade set for brick-wall construction 3-10 TECEbox washstand installation 3-11 TECEbox urinal flush valve housing U 1 3-12 TECEbox urinal flush valve housing U1 installation 3-12 TECEbox urinal flush valve housing U 2 3-14 Assembly and installation of TECEbox urinal flush valve housing U 2 3-14

Open the catalog to page 3
TECEbox - 4

System description System description TECE offers the TECEbox series especially for brick-wall constructions. For brick-wall construction installations, the TECEbox modules are wet-installed with mortar or concrete. For this purpose, the modules are installed and connected in front of a solid wall beforehand. Sound insulation is not neglected here, as proven by the sound insulation report from the Fraunhofer Institute in Stuttgart. As the modules are not self-supporting, they are not suitable for use in dry walls. TECEbox The standard variants of the TECEbox series are available for the...

Open the catalog to page 4
TECEbox - 5

Optional mounting feet are available as mounting aids for the standard installation height of the TECEbox ( item no. 9030024). Now fasten the expanded metal – see illustration. TECEbox assembly feet (item no. 9030024) TECEbox installation Align the TECEbox in front of the solid wall and screw it to the provided lugs (top) or basin brackets (bottom). The module must be completely built into the wall and all remaining cavities must be filled in. Install the bare-wall protection and the threaded rods. You can then apply the plaster and tile the surface. The wall structure must be at least 18...

Open the catalog to page 5
TECEbox - 6

Tip: A row installation with the TECEbox can be simplified using the TECEprofil pipe and corner joint. The brick-wall construction frames can be easily placed on the TECEprofil pipe via the side slots in the steel frame and fixed in place using the corner joint. This facilitates alignment. In this case, the modules only need to be screwed to the wall at the two top fastening lugs. Actuation from above: For actuation from above, a minimum distance of 200 mm from the wall to the front edge of the module must be maintained. The front structural panel serves as a minimal stem and must not be...

Open the catalog to page 6
TECEbox - 7

TECEbox plus The module must be completely built into the wall and all remaining cavities must be filled in. Install the barewall protection and the threaded rods. Now fasten the expanded metal – see illustration. Note: If the actuation is mounted from the front on cisterns with a low installation height and a compact ceramic is used, the toilet lid may fall shut unintentionally. Therefore, when using a compact ceramic, it should only be actuated from above! You can then apply the plaster and tile the surface. The wall structure must be at least 18 mm thick and no more than 100 mm thick....

Open the catalog to page 7
TECEbox - 8

TECEbox plus TECEbox plus TECEbox plus installation With the pre-mounted steel feet, the TECEbox plus can be simply placed in front of the wall and adjusted to the desired height. The TECEbox plus can be easily aligned and fastened via the depth-adjustable wall attachments. TECEbox plus brick-wall module (item no. 9371000) The TECEbox plus is a brick-wall module that is installed in front of a solid wall. It is characterised by a closed surface, which eliminates the need for the costly bricking-in of the cistern. The installation cover, which is available as an accessory, creates a...

Open the catalog to page 8
TECEbox - 9

TECEbox plus If the optionally available installation space cover is used, the lower installation space does not have to be bricked out. Installation of the lower installation space cover (item no. 9200012) is simple and, in addition, a continuous tileable surface is created immediately. A reinforcing fabric must be applied at the transition points from the lightweight glass fibre concrete slab to the masonry block to avoid possible tile cracks. The surface can then be tiled.

Open the catalog to page 9
TECEbox - 10

TECEbox washstand TECEone upgrade set for brick-wall construction As with dry-wall construction, an upgrade set is also used to connect the TECEone in brick-wall construction. The upgrade set is attached to the support frame of the TECE- box brick-wall module using two screws. The scope of delivery includes sound insulators and fastening screws which are used to fasten the wall discs for the cold and hot water connection. By mounting on the upgrade set, the wall discs are automatically in the correct position for connecting a TECEone. PWH warm hot chaud caliente caldo ciepła теплый PWC kalt...

Open the catalog to page 10
TECEbox - 11

TECEbox washstand TECEbox washstand TECEbox washstand (item no. 9370033) The connections for washstands in brick-wall construction are easy to install with the washstand frame. The all-round 8 cm deep steel frame with four depth-adjustable wall attachments is simply attached to any solid wall. All connection dimensions must be determined before bricking in and the elements must be fixed accordingly. The Installation dimensions cannot be changed subsequently. The distance range of the threaded rods to accommodate the washbasin ceramics has an adjustment range of 170280 mm. Once all the...

Open the catalog to page 11
TECEbox - 12

TECEbox urinal flush valve housing U 1 The TECE flush valve housing U 1 is pre-mounted on a holding plate and can therefore be easily recessed into a wall slot. Note: Before installation, the urinal ceramic to be used must be known. You should use the current connection dimensions from the ceramic manufacturer for this purpose. TECEbox urinal flush valve housing U 1 installation When installing the urinal flush valve, you must observe the installation depths and heights of the holding plate, housing and bare-wall protection. The flush valve housing is inserted into a slot in the wall and...

Open the catalog to page 12

All TECE Italia catalogs and technical brochures

  1. TECEprofil

    50 Pages

  2. FLUSH PLATES

    8 Pages