Introduction and Benefits
Trisomet® is an insulated panel system for roof and wall cladding, offering a one-fix construction method to enhance installation speed and reduce waste. Panels range from 300 mm to 20 m in length and 40 to 135 mm in core depth, achieving a U-value of 0.15 W/m²K. The system is validated for quality, thermal performance, fire safety, and environmental standards.
Platinum Plus® System Guarantee
The Platinum Plus® system guarantee offers a 25-year warranty for a complete building envelope solution, including Trisomet® panels and Colorcoat® pre-finished steel, ensuring compliance and reducing future risks.
Colorcoat® Products and Services
Colorcoat® provides pre-finished steel products with a Confidex® Guarantee of up to 40 years. Products like Colorcoat HPS200 Ultra® and Colorcoat Prisma® offer excellent color retention and corrosion resistance, with options to enhance energy efficiency.
System Performance Data
Trisomet® panels come in various thicknesses and lengths, with span/load tables to guide usage under different conditions, ensuring compliance with BS EN 14509 standards.
Building Regulation Requirements
The document outlines requirements for conserving fuel and power, ensuring Trisomet® panels meet necessary standards.
Roof and Wall Application Specifications
Specifications for roof and wall applications include construction details and installation guidance, with case studies like Jaffabox and Llanwern House showcasing successful applications.
Installation and Site Guidance
Guidance on fasteners, sealants, fillers, and installation procedures for roofs and walls ensures proper application and performance of the Trisomet® system.
Specifications
Trisomet® panels are designed for various applications with thicknesses from 40 mm to 135 mm, offering different U-values for thermal performance. They comply with building regulations in England, Wales, and Scotland.
Procedures
Installation involves specific fasteners and sealants for structural integrity and weather resistance, designed for installation on steel purlins with a minimum pitch of 4 degrees.
Standards
The panels meet standards like BS EN 14509 for water-tightness and BS 476 for fire safety, achieving a Grade AA rating for external surface spread of flame and fire penetration.
Recommendations
Alternative fastener layouts and purlin specifications can enhance performance. Panels suit various building types, including unheated buildings and those needing enhanced insulation.
Thermal Performance
Trisomet® panels provide consistent insulation, with U-values from 0.46 W/m²K for 40 mm panels to 0.15 W/m²K for 135 mm panels.
Fire Safety
The panels offer fire resistance with up to 4 hours of integrity and 22 minutes of insulation for certain thicknesses.
Acoustic Performance
Sound reduction index values are provided, with a weighted S.R.I RW of 28.5 dB for an 80 mm core.
Environmental Credentials
Trisomet® is sustainable with a low carbon footprint, zero ozone depletion potential, and high recyclability of steel elements.
Building Regulations Summary
The document outlines changes to building regulations, emphasizing energy performance and CO2 emission reductions.
Roof Applications
Trisomet® panels are specified for roof applications, ensuring compliance with relevant standards and regulations.
Specifications and Procedures
Detailed specifications for roof cladding systems focus on air sealing, thermal bridging, and flashing details, ensuring compliance with Tata Steel literature and building regulations.
Air Sealing and Thermal Bridging
Panel edges must be sealed with butyl mastic, achieving low air leakage and minimizing thermal bridging.
Platinum Plus® System Guarantee
Registration is required before tender distribution, with comprehensive support provided by Tata Steel.
General Requirements
Roof cladding design must adhere to Tata Steel guidelines, with specific materials and installation details provided.
Construction Details
Details for side laps, end laps, and junctions minimize thermal bridging and air loss, with specific instructions for gutter systems, parapets, and roof lights.
Specifications and Recommendations
Practical solutions to minimize thermal bridging and air loss at junctions are provided, with calculated Ψ and f values.
Construction Details - Wall
Details for side lap and end lap, vertical details, and internal/external corners are provided to enhance thermal performance and sealing.
Drip Detail Base and Dado Wall
Drip details reduce cold bridging at slab bases, with provided Psi values and f factors.
Window/Door Details
Specifications for window/door head, jamb, and sill emphasize trimming steelwork for support and sealing.
Penetration Options
Details on flexible pipe flashing systems for different opening sizes and temperature ranges are provided.
Vertical to Horizontal Break and Brick Wall Abutment
Details on maintaining thermal performance and weather seal when installing adjacent panels are provided.
Horizontal Details
Includes side lap and end lap details with emphasis on using silicon sealant for aesthetics and sealing.
Expansion Joint and Dado Wall Drip
Details on using 'V' formed flashing for movement at junctions are provided.
Roof Installation Procedure
Steps for roof installation include cleaning, aligning, and securing panels with specified fasteners and sealants.
Wall Installation Procedure
Steps for vertical and horizontal wall installation include preparing supports, aligning panels, and sealing.
Protective Film Removal
Trisomet panels' protective film should be removed within one month of delivery to avoid degradation.
Contact Information
Tata Steel, Shotton Works, Deeside, Flintshire, CH5 2NH, UK. Phone: +44 (0) 1244 892199
See more

Catalog excerpts

Trisomet®-1

Trisomet® External roof and wall panel system

 Open the catalog to page 1
Trisomet®-2

Contents 4-5 Introduction and benefits 6 Platinum Plus® system guaiantee 7 Coloicoat® products and services 8-10 System performance data 11 Summary of Building Regulation requirements for the conservation of fuel and power 12-13 Roof application model specification 14-24 Roof construction details 25 Jaffabox case study 26-27 Wall application model specification 28-38 Wall construction details 39 Fasteners, sealants and fillers 40-41 Site guidance 42-43 Roof installation 44-47 Wall installation

 Open the catalog to page 2
Trisomet®-3

Tata Steel Tata Steel is Europe's second largest steel producer. Our comprehensive range of high quality products and services are supported by steel making sites in the UK and The Netherlands, a European-wide distribution and service centre network and downstream businesses ranging from tubes and building systems to plating. Our approach to business is unique. We believe our strength is how we build collaborative relationships that create new success for our customers, adding value to their business and helping them to perform in their markets. As a company, we are dedicated to managing our...

 Open the catalog to page 3
Trisomet®-4

Trisomet® Trisomet® is an insulated panel manufactured as a single component suitable for both roof and wall cladding applications. As a one-fix component its consistency enables speed of installation and with a wide spaced trapezoidal steel external skin provides optimum performance for water drainage, strength and walkability. Technical Services Our dedicated building envelope technical team are available to provide support and advice on the best product for your project. They are on hand to help with: • Detail design. • Wind and snow loading. • U-value calculations. • Load span checks. • Acoustic...

 Open the catalog to page 4
Trisomet®-5

Case study Llanwern House, Llanwern Works, Newport Llanwern House, the new, energy efficient reception hub at Tata Steel’s Llanwern Works in Newport, features a cavalcade of our building envelope and structural solutions. The building has been entirely constructed using solutions by Tata Steel and has three floors. The ground floor will house conference facilities as well as a visitors' induction area. Floor One and Two feature an open-plan working environment, housing 200 employees. Client: Tata Steel Architect: Boys Rees Main contractor: Dawnus Envelope installer: Coverstructures South West...

 Open the catalog to page 5
Trisomet®-6

Main contractor: Barnwood Construction Ltd Cladding system: Trisomet® and Trimapanel Colorcoat® product: Colorcoat HPS200 Ultra' in Goosewing Grey and Colorcoat Prisma® in Silver Metallic Platinum Plus® system guarantee Platinum Plus® provides a complete building envelope solution guaranteed for 25 years. Designed in collaboration with our innovative supply chain of leading component manufacturers, our comprehensive portfolios of high quality products are fully integrated to provide the widest range of roofing and cladding systems. The Platinum Plus® guarantee includes, amongst others, the following...

 Open the catalog to page 6
Trisomet®-7

Colorcoat® products and services Trisomet® is only supplied with Colorcoat® pre-finished steel for the external and internal skin so that we can provide the very highest quality and service to our customers. Colorcoat® products and services Colorcoat® High Reflect The Colorcoat® brand provides the recognised mark of quality and metal envelope expertise exclusively from Tata Steel. For 50 years Tata Steel has developed a range of technically leading Colorcoat® pre-finished steel products which have been comprehensively tested and manufactured to the highest quality standards. Colorcoat® products...

 Open the catalog to page 7
Trisomet®-8

General panel information Thickness, t (mm) Maximum length (mm)1 Minimum length (mm) Cutback (mm)23 Minimum Maximum Weight (based on thickness mm) (kg/m2) 40 60 80 100 120 135 Tolerance is in accordance with BS EN 14509. General reference All measurements throughout this brochure are referenced in mm unless stated otherwise. Technical illustrations are not to scale. The panel length is measured by the length of the external sheet, as shown above. Lengths over 14000 mm will be subject to additional delivery charges. Panels will always have one flush end and one cutback end; therefore, they will...

 Open the catalog to page 8
Trisomet®-9

Safe imposed (positive) loads (kN/m2) Span condition Core thickness (mm) Safe wind suction (negative) loads (kN/m2) Span condition Core thickness (mm) Span (m) If safe loading shown above is not satisfactory to your requirements, it is possible to adjust performance by using alternative fastener layouts, purlin specifications and/or deflection limits. For further information please contact the Technical Department T: +44 (0) 1244 892199.

 Open the catalog to page 9
Trisomet®-10

Thermal performance Trisomet® complies with the minimum requirements of the conservation of fuel and power sections of the Building Regulations for England and Wales (Part L2) and Scotland (Technical Handbook Section 6 Energy). The panel construction offers highly consistent insulation performance, and the site-formed junctions provide a practical and effective method of ensuring good thermal performance. Water penetration In accordance with product standard BS EN 14509, the watertightness of a system should be tested to EN 12865. The standard advises that the system should achieve watertightness...

 Open the catalog to page 10
Trisomet®-11

Introduction to changes The latest amendment to the England AD-L2 and Wales Part L Regulations for the conservation of fuel and power (2013) came into effect on 6 April and 31 July 2014 respectively. The revision to Section 6 Scotland is scheduled for 2015. AD-L2 follows the principle of the 2010 Regulations but with significant changes in the definition of the types of buildings that make up the aggregate mix. As before, the whole building is assessed using the SBEM 'whole building methodology' that expresses the energy performance. Since it is the building services that emit CO2 and not the...

 Open the catalog to page 11
Trisomet®-12

H43 Insulated panel cladding/ covering 120 Insulated steel faced roof panel: Tata Steel, LPCB approved T risomet®. Cladding systems in England and Wales to be designed and installed to meet the Building Regulations 2000, Approved Document L2 2013. Cladding systems in Scotland to be designed and installed to meet the Building Standards (Scotland) Regulations Technical Handbook: Section 6 Energy. - Support structure: Steel purlins. - Bearing width (minimum): 60 mm end lap extension plates maybe required where three or more panels comprise the total roof slope. - Pitch: 4 degree minimum. - Manufacturer:...

 Open the catalog to page 12

All TATA STEEL catalogs and technical brochures

  1. Forcas

    8  Pages

  2. Colorcoat Urban

    12  Pages

  3. Colorcoat GP

    2  Pages

  4. Hybox® 355

    16  Pages

  5. ComFlor manual

    92  Pages

  6. RoofDek

    24  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.