Yanmar is dedicated to providing sustainable solutions essential for human life, focusing on food production and energy harnessing. With over a century of history, Yanmar has expanded globally, emphasizing efficiency and environmental responsibility. Their energy systems, including VRF, CHP, and power generation, are designed for integration and efficiency.
History of Yanmar Group
Founded in 1912, Yanmar developed the world's first small diesel engine and has since introduced innovations like the Gas Heat Pump (GHP) in 1987 and the world's first Gas Heat Pump Chiller in 2013.
Why Choose a GHP?
GHPs offer high-efficiency heating and cooling using natural gas, reducing CO2 emissions and electricity usage. They are a cost-effective alternative to electric heat pumps, especially where electric infrastructure is limited.
Benefits of a GHP
  • Capital Cost Savings: GHPs consume 90% less electricity than electric condensers, reducing infrastructure costs.
  • Efficiency: Up to 50% lower running costs compared to electric systems, depending on local tariffs.
  • Environmental Impact: GHPs are less greenhouse gas-intensive due to the inefficiency of electricity generation.
  • Peak Demand Reduction: Helps avoid peak demand charges and stabilize the grid.
  • Engine Heat Recovery: Utilizes engine heat to improve heating performance and avoid defrost cycles.
  • Lifecycle Costs: Despite higher initial costs, GHPs offer lower lifecycle costs due to reduced operating expenses.
Efficiency Calculation Comparison
GHPs demonstrate lower primary energy consumption compared to electric heat pumps and gas boilers, offering significant energy savings in cooling and heating applications.
Overview
Yanmar provides Gas Heat Pump (GHP) systems suitable for various building types, offering optimal heating and cooling solutions. These systems are available in air-to-water and air-to-air configurations, each with specific features to meet different climate needs.
System Solutions
  • Air-to-Water Systems: Utilize a heat exchanger to transfer thermal energy from the GHP refrigerant to the building's water pipes. Configurations include GHP Chiller and GHP with Hydrobox, both available with optional Domestic Hot Water (DHW) kits.
  • Air-to-Air Systems: Use Variable Refrigerant Flow (VRF) for heating and cooling. Configurations include GHP VRF heating & cooling system, GHP VRF heat recovery system, and GHP with direct expansion kit. Except for the heat recovery system, all configurations offer optional DHW kits.
Case Studies
  • Hotel Alcide, Italy: Installation of GHP Chiller with DHW kit resulted in a 60% reduction in energy consumption.
  • BVB Fanwelt, Germany: New building equipped with GHPs and Hydroboxes, providing energy-efficient heating and cooling.
  • Sparkasse Lippstadt, Germany: GHPs installed to climatize office buildings, complying with environmental regulations.
  • Cross Group, Ireland: GHP VRF system installed, leading to energy cost savings and a payback period within three years.
  • Grieshaber, Germany: Extensive GHP project for a pharmaceutical logistics complex, resulting in low maintenance and operating costs.
Product Solutions
Yanmar offers a range of main and indoor units designed for energy efficiency and optimal climate control. The GHP Chiller solution provides both chilled and hot water directly from the unit, with low electrical power consumption and no cooling tower maintenance.
Specifications
The ECWP710J model offers a cooling capacity of 71.0 kW and a heating capacity of 80.0 kW. It features a compact design, low noise levels, and uses natural gas as the primary energy source. The system includes advanced features like hot water recovery and a high-efficiency heat exchanger.
Technical Document Summary
1. Specifications
  • Dimensions: Height: 2,170 mm, Width: 1,690-2,100 mm, Depth: 800 mm.
  • Weight: Ranges from 880 kg to 1,080 kg.
  • Indoor Units Connection: Total capacity ranges from 50% to 130%, with a minimum capacity type of P22 and a maximum of 48 units connectable.
  • Electrical Characteristics: Single-phase power supply at 230 V, 50 Hz. Starting current ranges from 20 A to 25 A, with operating currents for cooling and heating specified.
  • Fuel Consumption: Natural gas cooling capacity ranges from 34.3 kW to 67.7 kW, and heating capacity from 32.5 kW to 66.3 kW.
  • Sound Pressure Level: Normal mode ranges from 57 dB(A) to 62 dB(A), and quiet mode from 54 dB(A) to 59 dB(A).
  • Refrigerant: Type R410A with a factory charge of 11.8 kg.
2. Product Solutions
  • DX-kit: Enables integration of non-VRV Air Handling Units into a Yanmar GHP system, enhancing system efficiency and design flexibility.
  • Key Features: Simple controller handling, network connection via Modbus or Ethernet, and continuous display of operational parameters.
3. Indoor Units
  • Round Flow Ceiling Cassette: Offers 360° airflow, energy savings up to 27%, and optional self-cleaning filter panel.
  • 4-Way Ceiling Cassette: Fits flush into ceiling grids, suitable for large spaces, and features a quiet operation.
  • Wall Mounted Unit: Designed for small rooms, offers programmable discharge angles, and reduced energy consumption.
  • Ceiling Suspended Unit: Slim design with low sound pressure levels, suitable for light commercial spaces.
  • Floor Standing Unit: Space-saving, suitable for under-window installation, with remote control options.
  • Concealed Floor Standing Unit: Ideal for classrooms and hospital rooms, offers flexible installation options.
  • DC Ducted Concealed Ceiling Unit: Suitable for various spaces, energy-efficient, and compatible with Daikin zoning kit.
4. Recommendations
  • Ensure proper installation to maintain rated heating and cooling outputs.
  • Consider environmental conditions and protection class (IP 54) for optimal performance.
  • Utilize optional accessories like Modbus/BACnet cards for enhanced connectivity.
Overview: The document provides detailed specifications and features of various indoor ducted units and accessories offered by Yanmar. It includes information on different models, their capacities, dimensions, and installation options, as well as additional accessories for enhanced functionality.
Specifications: The document outlines specifications for different models of indoor ducted units, including YFXDQ, YFXSQ, and YFXMQ-MB series. Key parameters include cooling and heating capacities, power consumption, dimensions, weight, airflow rates, sound pressure levels, and refrigerant type. The units are designed for residential, light commercial, and larger open space applications.
Installation and Design Flexibility: The units offer flexible installation options such as upflow, downflow, horizontal-left, and horizontal-right configurations. They are suitable for limited ceiling voids and bulkhead spaces, providing low sound levels and compact footprints.
Accessories: The document describes various accessories like remote monitoring adapters, remote controls, intelligent touch managers, and branch selectors. These accessories enhance energy management, provide user-friendly interfaces, and allow for individual heating and cooling options in heat recovery systems.
Software Tools: Yanmar provides software tools for system configuration, including design tools for VRF systems and merit software for energy consumption analysis.
Company Background: Yanmar, established in 1912, is a global provider of industrial equipment, including engines, agricultural machinery, and energy systems. The company is committed to sustainable solutions and enriching lives through innovative technologies.
Contact Information: The document includes contact details for Yanmar's head office in Japan and regional office in the Netherlands, along with their website for further information.
See more

Catalog excerpts

GHP Solutions-1

Cool Engineering. Smart Energy.

 Open the catalog to page 1
GHP Solutions-2

Logistics & Warehouse Industry Store & Shop

 Open the catalog to page 2
GHP Solutions-3

Yanmar GHP Versatile for all environments Sport & Leisure Home

 Open the catalog to page 3
GHP Solutions-4

Content Company Profile Building Solutions Yanmar mission statement History of Yanmar Group Efficiency calculation comparison Hotel Alcide, Italy Sparkasse Lippstadt, Germany   HP VRF heat recovery system G Cross Group, Ireland Grieshaber, Germany

 Open the catalog to page 4
GHP Solutions-5

Product Solutions Main units & Indoor units   Remote Monitoring Adapter  Remote control   Intelligent touch Manager  Branch Selector   GHP Heat Recovery Solution  Software tools Indoor units Non-Ducted   Round flow ceiling cassette   Wall mounted unit   Ceiling suspended unit   Floor standing unit Ducted   Concealed floor standing unit   DC ducted concealed ceiling unit   Slim concealed ceiling unit   Concealed ceiling unit (medium static)

 Open the catalog to page 5
GHP Solutions-7

“To conserve fuel is to serve mankind” Magokichi Yamaoka Founder of Yanmar

 Open the catalog to page 7
GHP Solutions-8

Yanmar mission statement We strive to provide sustainable solutions for needs which are essential to human life. We focus on the challenges our customers face in food production and harnessing power, thereby enriching people’s lives for all our tomorrows.

 Open the catalog to page 8
GHP Solutions-9

COMPANY PROFILE A sustainable future savings for our customers. Yanmar Energy Systems has created energy-responsible systems, including our VRF, combined heat and power (CHP), power generation and drive systems. These systems work independently or can be integrated with each other and your current systems, creating even greater efficiency and cost savings. At Yanmar, we pride ourselves on staying true to our mission for more than 100 years. We began in Japan and have since expanded into the global market, always remaining focused on providing sustainable, innovative solutions aimed at serving...

 Open the catalog to page 9
GHP Solutions-10

History of Yanmar Group Where it all began… The developer of the world’s first small diesel engine. Founder of Yanmar, Magokichi Yamaoka (1888 –1962) The vision “To conserve fuel is to serve the nation” Product introductions Industrial engines History of the Gas Heat Pump 1987 Yanmar Gas Heat Pump launched 2003 Yanmar Energy System CO., LTD. established in Japan Yanmar Gas Heat Pump heat recovery system l

 Open the catalog to page 10
GHP Solutions-11

COMPANY PROFILE Founded as Yamaoka Hatsudoki Kosakusho, started production of diesel engines Yanmar brand name adopted, a horizontal diesel engine model was developed 1947 Marine Recreational Propulsion systems Energy Systems Marine commercial engines Agricultural Equipment Construction Equipment Yanmar Energy Systems established in Europe Yanmar produces 250,000th Gas Heat Pump 2016 Yanmar develops World’s first Gas Heat Pump Chiller Yanmar develops World’s first Gas Driven Refrigerator 2012 Yanmar 100th Anniversary New Training Facility Opening

 Open the catalog to page 11
GHP Solutions-13

Introduction of a GHP What is a Gas Powered heat pump System? Yanmar’s Gas Powered Heat Pump units provide high efficiency heating and cooling for commercial buildings. By using natural gas and reversible air-source technology, these world-class engines deliver low operating costs, reduce CO2 emissions and use minimal electricity. While our GHP technology has been a preferred alternative to electric heat pumps (EHP) for 29 years, Yanmar’s innovations continue to refine GHP to its highest potential. In a Gas Powered heat pump system, a natural gas engine drives the compressors that compresses...

 Open the catalog to page 13
GHP Solutions-14

  Capital Cost Savings Reduced electric infrastructure A Gas Heat Pump unit operates on single phase power and significantly reduces electrical infrastructure and associates costs. Electrical infrastructure often requires floor space; reducing the size of electrical infrastructure often expands the floor area available to the developer and increases the commercial value of the building.  A Gas Heat Pump unit consumes around 90% less electricity than a similar electric condenser. Therefore, where power to the site is limited and upgrade costs are prohibitive, Gas Heat Pump systems provide a solution...

 Open the catalog to page 14
GHP Solutions-15

 Peak demand Reduced peak demand charges Gas Heat Pump systems help to avoid peak demand charges, thereby reducing operating costs. Flattening their demand profile in this way can also help customers to negotiate a more comparative tariff structure from their electricity supplier.  The demand for air conditioning in Europe is growing at a rapid rate and is expected to continue growing over the coming years. This growth is creating a substantial rise in the demand for power to run air conditioning. 100% Electric Electric Penalty Actual Electric Cooling versus Base Cooling versus Base Load using...

 Open the catalog to page 15
GHP Solutions-16

Efficiency calculation comparison Energy consumption of cooling/heating solutions Thermal Energy Demand (kWh) DHW** Winter Heating Gas boiler chimney + Chiller Gas fired absorption Heat Pump

 Open the catalog to page 16
GHP Solutions-17

Summer Cooling Electrical Heat Pump Climate region: Average temperature bin according to LOT 21 directive * Primary Energy Factor for electricity generation: based on 2012/27/EU directive * DHW temperature 65°C * * * Electrical Heat Pump DHW Energy consumption calculated considering R32 / R410A refrigerants + resistance heating Primary energy consumption (kWh)* 300,000 Boiler GAHP EHP GHP + Chiller DHW production covered by the free energy of Engine heat recovery 15

 Open the catalog to page 17
GHP Solutions-18

GHP in Europe Countries suitable for GHP technology based on energy costs  Countries suitable for GHP based on ROI calculations  Countries unsuitable for GHP based on ROI calculations

 Open the catalog to page 18
GHP Solutions-22

Cool Engineering. Smart Energy.

 Open the catalog to page 22
GHP Solutions-23

Overview BUILDING SOLUTIONS System solutions Whether it’s for offices, hotels, logistic centres or shops, Yanmar provides the best system solution for optimal heating and cooling for all kinds of spaces. Yanmar’s GHP is suitable for air-to-water and air-to-air systems and offers different configurations to suit the climate needs of your building. Air-to-water systems Air-to-air systems Air-to-water systems use a heat exchanger to convert the thermal energy from the GHP refrigerant to the building’s internal water pipes as the cooling and heating medium to the indoor units. Air-to-air systems...

 Open the catalog to page 23