Catalog excerpts

VR 400/700 DCV/DC Good ventilation For dwellings, smaller offices and business premises www.systemair.com
Open the catalog to page 1
2 Our indoor air Recent years research shows that we are less productive when we breathe poor quality indoor air. In general we spend up to 70% of our time indoors and in colder climates such as some parts of Northern Europe this can be as much as 90%. It goes without saying that the approximately 15 000 litres of indoor air that we breathe in daily should be fresh and oxygen rich but is this the case today? Yes, our offices as a rule have good ventilation, but it is in our homes where we often have problems. If we want good indoor air, we must have good ventilation, there are no short...
Open the catalog to page 2
3 of the building, and also limit the installed electric power in single houses with direct electrical heating as the main source of heating. The new regulations on energy management put great requirements on the design and workmanship. Ventilation, insulation and so on must be adapted to the lower energy use. A ventilation system that does not meet these demands or is poorly designed will not be helped by modern construction methods and could indeed contribute to poor air quality in the home. Well insulated houses can suffer with mould growth within the fabric of the building if there is...
Open the catalog to page 3
Solutions Home The VR 400/700 DC can be installed on a wall or in loft spaces. The picture shows a typical installation in a laundry room, but the location could just as well have been in the garage or in the basement. In the kitchen a separate kitchen extract fan with its own duct to roof cowl is installed. Small premises In smaller premises up to approx. 100 m2, such as offices and shops, the VR 400/700 DC are suitable for installation in loft space if available or on a wall. Control functions The new control system has a very user-friendly interface that makes it easy to commission and...
Open the catalog to page 4
5 VR 400/700 DCV and DC are complete air handling units suitable for homes, smaller offices and similar premises. With EC-fan motors and a new regulation system the energy use is optimized to be able to meet the new regulations on energy management. Compared to AC-motors EC-motors maintain efficiency throughout the motor speed range when speed controlled and are therefore suitable to use in demand controlled ventilation units. Measurements show that an EC-motor reduces the energy use with up to 50% compared to a traditional voltage controlled AC-motor. To ensure optimal operation, the...
Open the catalog to page 5
6 Technical data Energy saving functions Rotary heat exchanger with up to 80% heat recovery. No need for defrosting, which means continuous recovery of heat from the warm extract air. Separate adjustment of supply and extract air means less need of regulating dampers and thus avoiding increases in system pressure. Built-in week timer adapts the units operation to the buildings activities. For example, an office: Monday-Friday 08.00-17.00 Normal ventilation Remaining time Min. ventilation (incl. Saturday and Sunday) The cool recovery function is used in the summer in combination with an...
Open the catalog to page 6
Topvex.indd tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:15.00pt "Arial", sans-serif; } .font3 { font:7.00pt "Georgia", serif; } .font4 { font:4.00pt "Lucida Sans Unicode", sans-serif; } .font5 { font:4.00pt "Sylfaen", serif; } .font6 { font:7.00pt "Times New Roman", serif; } .font7 { font:8.00pt "Times New Roman", serif; } .font8 { font:9.00pt "Times New Roman", serif; } Dimensions VR 400 DCV/B 406 Left hand version 110 , 174 , 203 , 199 A B E °° C SU 216 186 174 110 B A ■3- 1^...
Open the catalog to page 11
Systemair AB • SE-739 30 Skinnskatteberg, Sweden Tel +46 222 440 00 • Fax +46 222 440 99 mailbox@systemair.se • www.systemair.com Systemair 2008 • Inhouse studio • Art no E8070
Open the catalog to page 12All Systemair catalogs and technical brochures
-
SYSAQUA_BLUE_H
24 Pages
-
DKIR1
3 Pages
-
MUB 016 200EC
5 Pages
-
KV DUO 150 EC
9 Pages
-
K 100 M sileo
10 Pages
-
SYSPLIT CASSETTE 09 EVO HP Q
4 Pages
-
MRT Catalogue
28 Pages
-
Fan Catalogue 2016
584 Pages
-
Smoke Extract Fans
12 Pages
-
SAVE Brochure
8 Pages
-
Fire Safety products
8 Pages
-
Hydronic Air Conditioning
268 Pages
-
DVu-HP
8 Pages
-
AHU Catalogue
174 Pages
-
Chillers - Air Conditioning
90 Pages
-
Grilles & Diffuser
24 Pages
-
Fan Catalogue
464 Pages
-
Air Conditioning - VRF
68 Pages
-
Fan Catalogue 2012
403 Pages
-
Systemair product news
20 Pages
-
Air Distribution Products
104 Pages
-
Residential Ventilation
64 Pages
-
Air Handling Units Catalogue 2012
138 Pages
-
Air Handling Units
80 Pages
-
Circular Duct Fan prioAir
6 Pages
Archived catalogs
-
Ventilation products 60 Hz
80 Pages
-
Systemair Diffusers
6 Pages
-
Systemair Air Curtains
6 Pages
-
Danvent DV
82 Pages
-
Maxi Air Handling Unit
16 Pages
-
Air handling units
76 Pages
-
Maxi Comfort 800
20 Pages
-
EC/DC Residential units
16 Pages
-
Fans with EC-motors
12 Pages
-
Air curtain
4 Pages
-
Systemair Air curtains
12 Pages
-
TSF exhaust diffuser
4 Pages
-
Systemair residential units
4 Pages
-
Topvex
60 Pages
-
KDRE/KDRD
8 Pages
-
TFSK/TFSR roof
6 Pages
-
Axial Fans
40 Pages
-
Systemair circular duct fans
6 Pages